SFP Controller with Dual LDD Interface

DS1876

DETECTION OF TXFOUT FAULT

TXFOUT

Figure 11a. TXFOUT Nonlatched Operation

DETECTION OF TXFOUT FAULT

TXD_ OR TXFOUT RESET

TXFOUT

Figure 11b. TXFOUT Latched Operation

Transmit Fault (TXFOUT) Output

START Condition: A START condition is generated TXFOUT can be triggered by all alarms, warnings, QTs, by the master to initiate a new data transfer with a TXD1, TXD2, TXF1, and TXF2 (see Figure 9). The six slave. Transitioning SDA from high to low while SCL ADC alarms and warnings are controlled by enable bits remains high generates a START condition. See (Table 01h/05h, Registers F8h and FCh). See Figures Figure 12 for applicable timing.

11a and 11b for nonlatched and latched operation for TXFOUT. The CNFGB register (Table 02h, Register 89h) STOP Condition: A STOP condition is generated controls the latching of the alarms.

by the master to end a data transfer with a slave. Transitioning SDA from low to high while SCL remains Die Identification

high generates a STOP condition. See Figure 12 for The DS1876 has an ID hardcoded in its memory. Two applicable timing.

registers (Table 02h, Registers 86h-87h) are assigned for this feature. Register 86h reads 76h to identify the Repeated START Condition: The master can use part as the DS1876; Register 87h reads the present a repeated START condition at the end of one data device version.

transfer to indicate that it will immediately initiate a new data transfer following the current one. Repeated 2C Communication

STARTs are commonly used during read operations to identify a specific memory address to begin a data I2C Definitions

transfer. A repeated START condition is issued identi-The following terminology is commonly used to describe cally to a normal START condition. See Figure 12 for I2C data transfers.

applicable timing.

Master Device: The master device controls the slave Bit Write: Transitions of SDA must occur during the devices on the bus. The master device generates SCL low state of SCL. The data on SDA must remain valid clock pulses and START and STOP conditions.and unchanged during the entire high pulse of SCL Slave Devices: Slave devices send and receive data plus the setup and hold time requirements (Figure 12). at the master’s request.

Data is shifted into the device during the rising edge of the SCL.

Bus Idle or Not Busy: Time between STOP and START conditions when both SDA and SCL are inac-Bit Read: At the end of a write operation, the master tive and in their logic-high states.

must release the SDA bus line for the proper amount of setup time (Figure 12) before the next rising edge

IC datasheet pdf-DS1876,pdf (SFP Controller with Dual LDD Interface)

______________________________________________________________________________________ 19

上一页第19页

你可能喜欢

热门文档

相关文档

站点地图 | 文档上传 | 侵权投诉 | 手机版
本站所有资源均来自互联网,本站只负责收集和整理,均不承担任何法律责任,如有侵权等其它行为请联系我们.
文档下载 Copyright 2013 doc.guandang.net All Rights Reserved.  -  email