The ADC results (after right-shifting, if used) are com-pared to the alarm and warning thresholds after each conversion, and the corresponding alarms are set that can be used to trigger the TXFOUT output. These ADC thresholds are user programmable, as are the masking registers that can be used to prevent the alarms from trig-gering the TXFOUT output.

shifts. Up to seven right-shift operations are allowed and are executed as a part of every conversion before the results are compared to the high and low alarm levels, or loaded into their corresponding measurement registers (Lower Memory, Registers 64h–6Bh). This is true during the setup of internal calibration as well as during subse-quent data conversions.

DS1876

ADC Timing

There are six analog channels that are digitized in a Low-Voltage Operation

round-robin fashion in the order as shown in Figure 4. The DS1876 contains two power-on reset (POR) levels. The total time required to convert all six channels is tThe lower level is a digital POR (POD) and the higher (see the Analog Voltage Monitoring Characteristics table RR level is an analog POR (POA). At startup, before the sup-for details).

ply voltage rises above POA, the outputs are disabled, all SRAM locations are set to their defaults, shadowed Right-Shifting ADC Result

EEPROM (SEE) locations are zero, and all analog cir-If the weighting of the ADC digital reading must conform cuitry is disabled. When VCC reaches POA, the SEE is to a predetermined full-scale (PFS) value defined by recalled, and the analog circuitry is enabled. While Va standard’s specification (e.g., SFF-8472), then right-remains above POA, the device is in its normal operating CC shifting can be used to adjust the PFS analog measure-state, and it responds based on its nonvolatile configu-ment range while maintaining the weighting of the ADC ration. If during operation VCC falls below POA, but is results. The DS1876’s range is wide enough to cover all still above POD, the SRAM retains the SEE settings from requirements; when the maximum input value is P 1/2 the first SEE recall, but the device analog is shut down the FS value, right-shifting can be used to obtain greater and the outputs disabled. If the supply voltage recovers accuracy. For instance, the maximum voltage might be back above POA, the device immediately resumes nor-1/8 the specified PFS value, so only 1/8 of the converter’s mal operation. If the supply voltage falls below POD, the range is effective over this range. An alternative is to cali-device SRAM is placed in its default state and another brate the ADC’s full-scale range to 1/8 the readable PFS SEE recall is required to reload the nonvolatile settings. value and use a right-shift value of 3. With this implemen-The EEPROM recall occurs the next time VCC next tation, the resolution of the measurement is increased by exceeds POA. Figure 5 shows the sequence of events a factor of 8, and because the result is digitally divided as the voltage varies.

by 8 by right-shifting, the bit weight of the measurement still meets the standard’s specification (i.e., SFF-8472).Any time VCC is above POD, the I2C interface can be used to determine if VCC is below the POA level. This The right-shift operation on the ADC result is carried is accomplished by checking the RDYB bit in the status out based on the contents of right-shift control registers byte (Lower Memory, Register 6Eh). RDYB is set when (Table 02h, Registers 8Eh-8Fh) in EEPROM. Four analog VCC is below POA; when Vchannels—PMON1, PMON2, BMON1, and BMON2—Fs) to go to 0, at which point the part CC rises above POA, RDYB is timed (within 500each have 3 bits allocated to set the number of right-is fully functional.

IC datasheet pdf-DS1876,pdf (SFP Controller with Dual LDD Interface)

Figure 4. ADC Round-Robin Timing

IC datasheet pdf-DS1876,pdf (SFP Controller with Dual LDD Interface)