康明斯技术参数
Alphanumeric Display Panel
The PowerCommand control is provided with an
alphanumeric display capable of displaying 2 lines of data with approximately 20 characters per line. The display is accompanied by a set of five tactile feel membrane switches that are used by the operator to navigate through control menus, and to make control adjustments. (There are no rotary potentiometers in the control. All adjustments are made via the display panel or InPower.) Display is configurable for multiple languages. It is configurable for units of measurement. All data on the control can be viewed by scrolling through screens with the navigation keys.
The control displays all active fault conditions with the latest displayed first. Active and inactive faults are displayed.
The display panel includes a screen-saver timer that will turn off the display after 10 minutes of inactivity. Touching any key will turn the screen back on. Generator Set Hardware Data - Generator set rating in kVA, Generator set model number. The control stores the software version present in the control. Data Logs - Number of start attempts and duration of generator set running time. Generator set kWh produced.
Fault History - Provides a record of the most recent fault conditions with time stamp. Up to 20 events are stored in the control non-volatile memory.
Load Profile Data – Control logs data indicating the operating hours at percent of rated kW load, in 10% increments. InPower is used to read this.
Generator Set Output Voltage - all phases, line to line and line to neutral, accuracy 1%. Data for all phases is displayed simultaneously to allow viewing of voltage balance.
Generator Set Output Current - all phases, accuracy 1%. Data for all phases is displayed simultaneously to allow viewing of load balance. Generator Set Output Frequency
Generator Set Power Output - PowerCommand displays generator set kW (total power), and power factor with leading/lagging indication. Accuracy 5%. Generator Set kWh Power Output - Displays total kilowatt-hours produced by the generator set. Engine Starting Battery Voltage Engine Lube Oil Pressure Engine Coolant Temperature Engine Lube Oil Temperature Engine Exhaust Temperature (Option)
Service Adjustments – The operator panel includes provisions for adjustment and set up of all control
functions in the generator set. The operator panel includes an access code that is used to protect the control from unauthorized service level adjustments.
Internal Control Functions Engine Control
Remote Start Mode - PowerCommand accepts a
ground signal from remote devices or a network signal to automatically start the generator set and immediately accelerate to rated speed and voltage.
PowerCommand includes a Smart Starting system, that is designed to quickly start the engine, minimize black smoke, and minimize voltage and frequency overshoot and oscillations on starting. The control system does this by careful control of the engine fuel system and alternator excitation system.
The control can incorporate a time delay start and a warm-up period at idle speed. See Engine Governing for details.
Sleep Mode – PowerCommand can be configured to include a sleep mode. When enabled, and when the mode select switch is in the OFF position, the control will revert to a low power consumption mode until a control switch on the operator panel is operated or a remote start signal is received.
Fault Simulation Mode - PowerCommand, in conjunction with InPower software, will accept
commands to allow a technician to verify the proper operation of all protective functions of the control, by simulating failure modes or by forcing the control to operate outside of its normal operating ranges. Engine Starting – The control system automatically controls the engine starter, and provides proper engine fueling and alternator control to provide fast and efficient starting.
Cycle Cranking - Configurable for number of starting cycles (1 to 7) and duration of crank and rest periods. Control includes starter protection algorithms to prevent the operator from specifying a starting sequence that might be damaging.
Time Delay Start And Stop (cooldown) -
Configurable for time delay of 0-300 seconds prior to starting after receiving a remote start signal, and for time delay of 0-600 seconds prior to ramp to idle or shut down after signal to stop in normal operation modes. Default for both time delay periods is 0 seconds.
TM
2004 年 8 月修订 第 1-1 康明斯东亚培训中心 康明斯 PCC3100 控制器培训讲义万世祥 编辑 2004 年 8 月修订 第 1-2 康明斯东亚培训中心 康明斯 PCC3100 ...
电路板位置 2004 年 8 月修订 第 1- 2页 康明斯东亚培训中心 康明斯 PCC3100 控制器培训讲义万世祥 编辑 方框图 2004 年 8 月修订 第 1- 3页 康明斯东亚...
康明斯2012柴油发电机并机控制器 Digital PC3100 正式...Cummins Power Generation, and are covered by a ...康明斯柴油发电机组PCC3... 13页 1下载券 东风康明斯...
康明斯东亚培训中心 康明斯 PCC3100 控制器培训讲义万世祥 编辑 第 2 章 PCC3100 操作介绍本节介绍发电机组的一般操作,发电机组的具体操作步骤及注意事项请严格按...
3100 3100 3100 3300 3450 3350 3550 3750 4350 4650 4650 4650 4850 1200 1212 1212 1212 1400 1466 1488 2020 1790 1870 1870 1870 1870 2070 960 972 972...
3100*1050*1750 3000KG 1、柴油机主要参数 品牌: 产地: 柴油机型号: 最大功率: 类型: 冷却方式: 排列型式: 气缸数: 缸径*行程: 排量: 机油容量: 转速: ...
(从空载到 100%负载) 5.14 机组外形尺寸:长×宽×高约 3100×940×1690mm(具体实际尺寸详见正式蓝图) 六、机组结构组成 6.1 柴油机 6.1.1 柴油机厂商与...
3100×1060×1900 3050×970×1600 3100×1060×1900 3100×1060×1900 3100×1060×1900 3300×1090×1850 3400×1300×2000 3300×1090×1850 3400×1300×2000...
3100×1050×1800 330GF1 360GF 330GF 400GF 450GF 420GF 505GF 520GF ...康明斯柴油发电机组PCC3... 21页 1下载券 300KW康明斯柴油发电机组... 3页 ...
·h 外形尺寸:3100×1250×1650(L×W×H mm) 发动机冷却方式:满足环境温度 40℃散热器,皮带驱动冷却风扇 发电机技术参数: 材质: 纯铜 电压控制方式:AVR 额定...
热门文档