原文
3. TECHNICAL REQUIREMENTS
In the event of a conflict between this specification and the document citing this specification, that document shall prevail. 3.1
Pyrometry shall conform to AMS2750 furnace class 5, instrumentation type D, as a minimum.
3.2 Heat treatment equipment shall conform to AMS2759 and requirements specified herein. Furnaces shall be
circulating-air type. 3.3 Procedure 3.3.1 Cleaning
Parts shall be clean prior to baking. 3.3.2
Racking and Spacing
Parts shall be placed in racks or trays, made of mesh or expanded metal, or supported or suspended so as to allow free circulation of the heating medium, except small parts may be randomly arranged in trays providing that layers of parts are not thicker than 2 inches (51 mm) and the distance between the layers is not less than 2 inches (51 mm). 3.3.2.1
Thickness of layers of small parts randomly arranged in trays may be greater than 2 inches (51 mm), provided tests have been made with load thermocouples to confirm that the center of the coldest load will reach the set temperature minus 25 °F (14 °C) within one hour of loading.
Parts shall be baked after the completion of the chemical processing or plating designated in Table 1 or 2. (See 8.2.) Delay Time Limits
3.3.3 3.3.3.1
The elapsed time between completion of plating or other chemical processing operations and start of heating parts in the baking furnace shall not exceed 4 hours except, when baking is required after etch inspection (refer to footnote 4 of Tables 1 and 2) to detect abusive grinding or machining, the elapsed time shall not exceed 24 hours. 3.3.3.2 3.3.3.2.1
Bake Set Temperature
Standard bake set temperature shall be 375 °F (191 °C) in accordance with Table 1, nonstandard baking set temperatures listed in Table 2 shall be used for parts made from the following materials/processes:
Carburize or carbonitride case hardening heat treatment AISI 52100 steel
Type 440C corrosion and heat resisting steel
Music wire
3.3.3.3
Other alloys tempered below 400 °F (204 °C).
Bake Soak Time
Bake soak time shall be as designated in Table 1 or 2, as applicable. 3.3.3.4
Start of Soak Time
Soaking time shall commence when parts are placed in the furnace, the furnace door(s) are closed, and the temperature
indicated by the furnace control instrument is within 25 °F (14 °C) of the set temperature.
AMS2759-5D中文版_机械/仪表_工程科技_专业资料。马氏体不锈钢零件的热处理 1. 范围 本规范连同 AMS 2759 中提及的钢的热处理的一般要求一起, 构成了马氏体 ...
AMS 2759-9D-2009 钢制零件... 5页 5财富值 SAE AMS 5732J-2006 固溶热... 7页 10财富值 AMS H-6875A美国的军用热处... 29页 5财富值 AMS_5630G...
AMS2759_交通运输_工程科技_专业资料。AEROSPACE MATERIAL SPECIFICATION AMS 2759... AMS2759-9D 5页 1下载券 AMS2759-1E 13页 1下载券 AMS2759-8A 13页 1...
AMS2759-3E_机械/仪表_工程科技_专业资料。美国国家标准今日推荐 ... AMS2759-2E AMS2759-5D AMS2759-8A AMS2759-9D AMS2759-9c1/2 相关文档...
AEROSPACE MATERIAL SPECIFICATION AMS 2759/9B Issued Revised NOV 1996 APR 2003... AMS 2759-7A 15页 1下载券 AMS 2759-9D-2009 钢制零... 5页 2下载券 ...
AMS2759-1E_机械/仪表_工程科技_专业资料。美国国家标准今日推荐 ... AMS2759-2E AMS2759-3E AMS2759-5D AMS2759-8A AMS2759-9D AMS2759-9c ...
环境 气态/燃烧废气 氩 3/ 氦 3/ 氢 3/ 氮 ...本文档零部件的任何参照被 AMS 2759 的相应要求取代...B 和 D 钢制热处理材料的硬度检测:最终热处理后的...
AMS2759-9D 5页 1下载券 AMS2759-5D 11页 1下载券 AMS2759-9c 5页 1下载券 AMS2759-5D中文版 8页 2下载券 AMS2759-3E 15页 1下载券 喜欢此文档的...
AMS2759-11_机械/仪表_工程科技_专业资料。美国国家标准今日推荐 ... AMS2759-9D 5页 1下载券 AMS2759_2F 暂无评价 13页 1下载券 AMS2759-5D...
2 AMS 2759/3C 3.3.1 果热处 ℉(774 热处理环境: 零件必须在空气中或保护气氛中热处理, 可接受的保护气氛包括氩、 氦、氢中性盐和真空。氮和氮氢混和物...
热门文档