_燃烧热的测定_的改进及用Origin软件处理实验数据

22化工技术与开发 第 41 卷

光谱法测定中药材中的痕量汞[J].中国卫生检验杂志,2011,21(2):346-347.

[39] 彭湘君,李银保,余磊,李青松.微波消解-氢化物

发生-原子荧光光谱法测定7种中草药中砷[J].光谱实验室,2006,23(6):1201-1203.

[40] 朱永琴,石杰.氢化物发生-原子荧光光谱法测定中

药中的痕量砷[J].光谱实验室,2010,27(4):1651-1654.

[41] 苏召飞,杨新安,朱兴江,张王兵.氢化物发生原子

荧光法同时测定中药中的锗和硒[J].安徽工业大学学报(自然科学版),2010,27(3):277-280.

[42] 曾晓丹,朱琳,王建刚.氢化物发生-原子荧光光

谱法同时测定中药材中砷和汞[J].分析科学学报,2010,26(4):478-480.

[43] 杨莉丽,李娜,张德强.氢化物发生-双道原子荧光

光谱法同时测定中药中不同形态的砷和锑[J].光谱学

与光谱分析,2007,27(4):810-812.

[44] 胡友波,李东刚,李俊伟,孙长华,李妍.氢化物发

生-原子荧光光谱法测定生物血中硒[J]. 化学工程师,2007,19(7):25-26.

[45] 王长芹,刘贵勤.超声提取-顺序注射氢化物发生-原子荧光光谱法测定煤中无机砷[J].冶金分析,2011,31(3):46-49.

[46] 王长芹,公维磊,杨金玲.李庆苓. 顺序注射氢化物

发生-原子荧光法测定洗洁精中的砷[J]. 分析仪器,2011,(1):45-47.

[47] 何海成,王玉琴,丁虎,段文凤,张洁.氢化物发

生-原子荧光法测定沼液中砷的含量[J].可再生能源,2011,29(3):57-60.

[48] 张克梅,王文静.湿法消化-氢化物原子荧光法测定

尿中砷[J].中国卫生检验杂志,2011,21(4):856-858.

Development of Hydride Generation-Atomic Fluorescence Spectrometry

LIU Bin

(School of Environmental and Chemical Engineering, Xi′an Polytechnic University, Xi′an 710048, China)

Abstract: The method of hydride generation-atomic uorescence spectrometry (HG-AFS) was now important analytical techniques, that was determined the trace elements of hydride or gaseous compounds. A review of the progress of hydride generation-atomic uorescence spectrometry for micro determination in the recent ve years was given in this paper. Prospect on the future progress of hydride generation-atomic uorescence spectrometry was also given.

Key words: hydride-generation; atomic uorescence spectrometry; development

(上接第11页)

Improvement in Combustion Heat Determination and Experimental Data Processing

by Origin Softwear

YI Jun-hui, GONG Fu-zhong

(1. Department of Resources Engineering, Guangxi Modern Polytechnic College, Hechi 547000, China; 2. School of Chemistry and

Chemical Engineering, Guangxi University, Nanning 530004, China) Abstract: To solved the problem of the low success rate and long experimental time in combustion heat determination, two improved experimental technologies were brought up. It proved that the whole experimental process time was shortened, experimental one-time burning a success rate was up to 99%. The experimental data obtained by using Origin software for processing, the results were consistent with literature values; the relative error was only 0.022%. The error reduced greatly with Origin software for processing, and the data processing was quick.

Key words: combustion heat determination; improvement; Origin software; data processing