Study on the Permanent Magnet Demagnetization Fault in Permanent Magnet Synchronous Machines

永磁同步电机永磁体抗去磁能力的研究

Figures 11 to 15 show the zero sequence current spectrum, which is the algebraic sum of the third harmonic current of the rotor for each phase and its multiples, except for the stator’s third harmonics because of the star connection of the winding without neutral.

Using this current’s spectrum it is possible to determine the permanent magnet demagnetization fault for high and low speeds, especially in the third harmonic, yet also for harmonics 6, 12 and 15 with high and medium speeds. The differences in amplitude for these harmonics range from 2.5 to 1.5 times, and they are smaller at low speeds.

The zero sequence current adds the first harmonic to its multiples vectorially. Given the 120 degree gap between phases in the first harmonic, this is cancelled, and so are its multiples, except for the third harmonics. Since these are fault indicators, and cannot be cancelled by the zero current sequence, fault condition of whatever type will become more obvious in their case, including stator tension imbalances. It is simple to obtain the zero sequence current, either by adding the three phase currents, or by directly measuring on the conductors.

Study on the Permanent Magnet Demagnetization Fault in Permanent Magnet Synchronous Machines

Amplitude (pu)Harmonics

IV. CONCLUSIONS

The variations in amplitude of the value of the harmonics for motors with demagnetization faults on the range of speeds force the consideration of more than one harmonic for the detection of faults. Hence, it will be the overall behavior of all of them which will enable the determination of the fault condition.

The zero sequence current makes is possible to determine the permanent magnet demagnetization fault in high and low speeds with a correct degree of accurateness and determination.

The stator current harmonics show the fault condition for medium and high speeds. The proper combination of the analyses of current and speed, or stator and zero sequence current, or zero sequence and q axis current enables fault determination for any range of speeds. Furthermore, this analysis can be extended to the remaining faults, such as eccentricities and bearing faults.

Study on the Permanent Magnet Demagnetization Fault in Permanent Magnet Synchronous Machines

Amplitude (pu)

Fig. 10. Stator current harmonics for PMSM. 300 rpm.

Study on the Permanent Magnet Demagnetization Fault in Permanent Magnet Synchronous Machines

Amplitude (pu)Fig. 13. Zero sequence current harmonics for PMSM. 3000 rpm.

Amplitude (pu)

Harmonics

Study on the Permanent Magnet Demagnetization Fault in Permanent Magnet Synchronous Machines

Harmonics

Fig. 11. Zero sequence current harmonics for PMSM. 6000 rpm.

Amplitude (pu)

Study on the Permanent Magnet Demagnetization Fault in Permanent Magnet Synchronous Machines

Fig. 14. Zero sequence current harmonics for PMSM. 1500 rpm.

Study on the Permanent Magnet Demagnetization Fault in Permanent Magnet Synchronous Machines

Harmonics

Harmonics

Fig. 12. Zero sequence current harmonics for PMSM. 4500 rpm.

Harmonics

Amplitude (pu)

Fig. 15. Zero sequence current harmonics for PMSM. 300 rpm.