永磁同步电机永磁体抗去磁能力的研究
ACKNOWLEDGMENT
The authors would like to acknowledge the economic support received from the Spanish Ministry of Science and Technology for realizing this work under the DPI 2004-03180 Research Project.
Also, the work was supported by the Programme Alban, the European Union Programme of High Level Scholarships for Latin America, scholarship No.E04D027632CO, Mr. J.A. Rosero.
REFERENCES
[01] J. A. Haylock, B. C. Mecrow, A. G. Jack, D. J. Atkinson, “Operation
of a fault tolerant PM drive for an aerospace fuel pump application,” Eighth International Conference on Electrical Machines and Drives, 1997 (Conf. Publ. No. 444), pp. 133 – 137, 1-3 Sept. 1997. [02] P. Pillay, M. A. Wu, “A computer program to predict the performance
of permanent magnet synchronous motor drives,” Proceedings, IEEE Southeastcon '92, vol. 2, pp. 517 – 522, 12-15 April 1992.
[06] S. Nandi, H. A. Toliyat, “Condition monitoring and fault diagnosis of
electrical machines - a review,” IEEE IAS Thirty-Fourth Meeting Industry Applications Annual Conference, vol. 1, pp. 197 – 204, 3-7, Oct. 1999. [07] P. Vas, Parameter Estimation, Condition Monitoring, and Diagnosis of
Electrical Machines, Clarendron Press, Oxford, 1993. [08] N. Ertugrul, W. L. Soong,S. Valtenbergs, H. Chye, ”Investigation of a
fault tolerant and high performance motor drive for critical applications,” TENCON. Proceedings of IEEE Region 10 International Conference on Electrical and Electronic Technology, 2001. vol. 2, pp. 542-548, 19-22 Aug. 2001. [09] J. A. Haylock, B. C. Mecrow, A. G. Jack, D. J. Atkinson, ”Operation of
fault tolerant machines with winding failures,” IEEE Transactions on Energy Conversion, vol. 14, Issue 4, pp.1490 – 1495, Dec. 1999. [10] R. R. Schoen, B. K. Lin, T. G. Habetler, J. H. Schlag, S. Farag, “An
unsupervised on-line system for induction motor fault detection using stator current monitoring,” IEEE Trans. Ind. Appl., vol 31, no. 6, pp 1280-86, Nov-Dec 1995. [11] B. Yazid, G. B. Kliman, W. J. Premerlani, R. A. Koegl, G. B. Robinson
and A. Abdel-Malek, ‘An adaptive. on-line, statistical method for bearing fault detection using stator anent”, IEEE-IAS Annual Meeting conference, pp 213- 220, New Orleans, LA, 1997.
[03] P. Pillay, R. Krishnan, ”Modelling, simulation, and analysis of
permanent-magnet motor drives. I. The permanent-magnet [12] W. Le Roux, R. G. Harley, T. G. Habetler, ”Detecting rotor faults in
permanent magnet synchronous machines,” IEEE International synchronous motor drive,” IEEE Transactions on Industry
Symposium on Diagnostics for Electric Machines, Power Electronics Applications, vol. 5, Issue 2, pp. 265-273, March-April 1989.
and Drives, 2003. SDEMPED 2003, pp. 198-203, 24-26 Aug. 2003.
[04] P. Pillay, R. Krishnan, ”Modelling, simulation, and analysis of
permanent-magnet motor drives. I. The permanent-magnet [13] W. Le Roux, R. G. Harley, T. G. Habetler, “Converter control effects
on condition monitoring of rotor faults in permanent magnet synchronous motor drive,” IEEE Transactions on Industry
synchronous machines,” 38th IAS Annual Meeting. Conference Applications, vol. 5, Issue 2, pp. 274-279, March-April 1989.
Record of the Industry Applications, vol. 2, pp. 1389 – 1396, 12-16
[05] Mohamed El Hachemi Benbouzid: “A Review of Induction Motor Oct. 2003.
Signature Analysis as a Medium for Faults Detection”, IEEE
[14] T. J. E. Millar, “Brushless permanent magnet and reluctant motor Transactions on Industrial Electronics, vol. 47, nº 5, pp. 984-993, Oct
drives,” Oxford University Press, 1989. 2000.
Demagnetization Analysis of Permanent Magnet Synchronous Machines under Short Circuit Fault 隐藏>> Demagnetization Analysis of Permanent Magnet Synchronous Machines...
Influence+of+design+parameters+on__+cogging+torque+in+permanent+magnet+...Influence of Design Parameters on Cogging Torque in Permanent Magnet Machines ...
(cont’d) Transients or machine faults can lead to a worst-case demagnetization as shown which results in permanent demagnetization of the permanent magnet...
536. , “Comparative study of permanent magnet brushless machines [10] with...uence of design parameters on cogging torque in permanent magnet machines,”...
The Feasibility Study of Permanent Magnet Coupling Applied in Scraper Conveyor_理学_高等教育_教育专区。The Feasibility Study of Permanent Magnet Coupling ...
Researches on End Effects of Permanent Magnet Electromagnetic Launchers_天文/地理_自然科学_专业资料。201 3年 第1 3期 SCIENCE&TECHNOLOGY INFORMATION 0外语论...
Permanent Magnet Rotor Assembly_机械/仪表_工程科技_专业资料。永磁结构设计...magnets to have Br = 10 kG and a linear second quadrant demagnetization ...
Influence of Design Parameters on Cogging Torque in Directly Driven Permanent Magnet Synchronous_专业资料。今日推荐 50份文档 2014年注册会计师考试...
Localization for the Non-Invasive Detecting Capsule in GI Tract Utilizing Permanent Magnet and M_专业资料。维普资讯 http://www.cqvip.com Junlora ofDogu ...
Torque in Directly Driven Permanent Magnet Synchronous_机械/仪表_工程科技_专业...Sebastian. “Study of cogging torque in permanent magnet machines”. IEEE ...
热门文档