The specifications of the used power inverter suggest that the control type is “Maximum Torque per Ampere” (MTPA), i.e., with id=0 and maximum current iq. However, the flow loss in the air gap can only be compensated by the extra input of flow with id>0. Hence, to keep the flow constant in the air gap the load angle must be reduced, so that iq can be reduced and id, can increase to try to bring the flow back to its constant nominal value. That implies that the d axis current reference value is no longer zero, and rises to a 5 % value of the nominal to increase the flow and to help generate the nominal torque (Fig. 5).
Table 1. Nominal Data for PMSM



Pole pairs
3
EMF constant
57.6
s/krpm
Amplitude (pu)
Figures 6 to 10 show the current harmonics for the stator for PMSM at 6000 rpm, 4500 rpm, 3000 rpm, 1500 rpm and 300 rpm, respectively.
For speeds from 6000 rpm to 3000 rpm, stator current harmonics 1 and 5 point out clear differences for a fault machine, with a difference that ranges from 5 to 0.6 times. For extremely low speeds (Fig. 10), however, it is very hard to detect a fault with these harmonics.
In the medium speed range, stator current harmonics 13 and 17 also show noticeable differences between damaged and healthy machines, with ratios higher than double. In low speeds, from 1500 rpm to 300 rpm, it is stator current harmonics 6 and 9 which present the greater differences in the case of demagnetization damage in the rotor.
Fig. 6. Stator current harmonics for PMSM.. 6000 rpm.

Fig. 7. Stator current harmonics for PMSM. 4500 rpm.
Amplitude (pu)Harmonics

Fig. 4. q axis current for PMSM magnetized to 50 %. 6000 rpm. iq
(rms) =0.82 pu.
Fig. 8. Stator current harmonics for PMSM. 3000 rpm.

Amplitude (pu)Harmonics
Fig. 5. d axis current for PMSM magnetized to 50 %. 6000 rpm. id
(rms) = 0.065 pu.
Fig. 9. Stator current harmonics for PMSM. 1500 rpm.
Harmonics
Demagnetization Analysis of Permanent Magnet Synchronous Machines under Short Circuit Fault 隐藏>> Demagnetization Analysis of Permanent Magnet Synchronous Machines...
Influence+of+design+parameters+on__+cogging+torque+in+permanent+magnet+...Influence of Design Parameters on Cogging Torque in Permanent Magnet Machines ...
(cont’d) Transients or machine faults can lead to a worst-case demagnetization as shown which results in permanent demagnetization of the permanent magnet...
536. , “Comparative study of permanent magnet brushless machines [10] with...uence of design parameters on cogging torque in permanent magnet machines,”...
The Feasibility Study of Permanent Magnet Coupling Applied in Scraper Conveyor_理学_高等教育_教育专区。The Feasibility Study of Permanent Magnet Coupling ...
Researches on End Effects of Permanent Magnet Electromagnetic Launchers_天文/地理_自然科学_专业资料。201 3年 第1 3期 SCIENCE&TECHNOLOGY INFORMATION 0外语论...
Permanent Magnet Rotor Assembly_机械/仪表_工程科技_专业资料。永磁结构设计...magnets to have Br = 10 kG and a linear second quadrant demagnetization ...
Influence of Design Parameters on Cogging Torque in Directly Driven Permanent Magnet Synchronous_专业资料。今日推荐 50份文档 2014年注册会计师考试...
Localization for the Non-Invasive Detecting Capsule in GI Tract Utilizing Permanent Magnet and M_专业资料。维普资讯 http://www.cqvip.com Junlora ofDogu ...
Torque in Directly Driven Permanent Magnet Synchronous_机械/仪表_工程科技_专业...Sebastian. “Study of cogging torque in permanent magnet machines”. IEEE ...
热门文档