Study on the Permanent Magnet Demagnetization Fault in Permanent Magnet Synchronous Machines

永磁同步电机永磁体抗去磁能力的研究

The specifications of the used power inverter suggest that the control type is “Maximum Torque per Ampere” (MTPA), i.e., with id=0 and maximum current iq. However, the flow loss in the air gap can only be compensated by the extra input of flow with id>0. Hence, to keep the flow constant in the air gap the load angle must be reduced, so that iq can be reduced and id, can increase to try to bring the flow back to its constant nominal value. That implies that the d axis current reference value is no longer zero, and rises to a 5 % value of the nominal to increase the flow and to help generate the nominal torque (Fig. 5).

Table 1. Nominal Data for PMSM

Study on the Permanent Magnet Demagnetization Fault in Permanent Magnet Synchronous Machines

Study on the Permanent Magnet Demagnetization Fault in Permanent Magnet Synchronous Machines

Study on the Permanent Magnet Demagnetization Fault in Permanent Magnet Synchronous Machines

Pole pairs

3

EMF constant

57.6

s/krpm

Amplitude (pu)

Figures 6 to 10 show the current harmonics for the stator for PMSM at 6000 rpm, 4500 rpm, 3000 rpm, 1500 rpm and 300 rpm, respectively.

For speeds from 6000 rpm to 3000 rpm, stator current harmonics 1 and 5 point out clear differences for a fault machine, with a difference that ranges from 5 to 0.6 times. For extremely low speeds (Fig. 10), however, it is very hard to detect a fault with these harmonics.

In the medium speed range, stator current harmonics 13 and 17 also show noticeable differences between damaged and healthy machines, with ratios higher than double. In low speeds, from 1500 rpm to 300 rpm, it is stator current harmonics 6 and 9 which present the greater differences in the case of demagnetization damage in the rotor.

Fig. 6. Stator current harmonics for PMSM.. 6000 rpm.

Study on the Permanent Magnet Demagnetization Fault in Permanent Magnet Synchronous Machines

Fig. 7. Stator current harmonics for PMSM. 4500 rpm.

Amplitude (pu)Harmonics

Study on the Permanent Magnet Demagnetization Fault in Permanent Magnet Synchronous Machines

Fig. 4. q axis current for PMSM magnetized to 50 %. 6000 rpm. iq

(rms) =0.82 pu.

Fig. 8. Stator current harmonics for PMSM. 3000 rpm.

Study on the Permanent Magnet Demagnetization Fault in Permanent Magnet Synchronous Machines

Amplitude (pu)Harmonics

Fig. 5. d axis current for PMSM magnetized to 50 %. 6000 rpm. id

(rms) = 0.065 pu.

Fig. 9. Stator current harmonics for PMSM. 1500 rpm.

Harmonics