Study on the Permanent Magnet Demagnetization Fault in Permanent Magnet Synchronous Machines

永磁同步电机永磁体抗去磁能力的研究

[R]=diag[rs

rs λq

rs] 0

[λ]=[λ

Tqd

[ΦPM]T=[0

[λ]=[M][i]+[Φ]

Tqdo

qdo

qdo

PM

d

]

[M]

qdo

ΦPM0]

=DiagLqLdLo

[

]

(2)

Fig. 2. q axis current for healthy PMSM. 6000 rpm.

iq

Study on the Permanent Magnet Demagnetization Fault in Permanent Magnet Synchronous Machines

(rms) =1.05 pu

where index this v, i, L, λ, are voltages, stator currents, inductances and stator flux linkages. Subindex d, q and 0 represent values in dq0 frame. rs and ω are the stator resistance and inverter frequency, respectively, and ΦPM is the flux linkage due to the rotor magnets linking the stator. The electric torque is

Te=

3p

ΦPMiq+(Ld Lq)iq.id 22

[]

(3)

and the equation for the motor dynamics is

θ ω

J=Te Tl Bω =ω

t t

(4)

Fig. 3. d axis current for healthy PMSM. 6000 rpm. id (rms) =0.01 pu

III. EXPERIMENTAL RESULTS

In the studied motors the demagnetization defect was

induced by magnetizing a pole pair in the machine (during the manufacturing process) at 87%, 75% and 50% of the nominal magnetization.

In a real industrial application, the magnet can be demagnetized by fault currents, such as short circuit currents produced by inverter faults, by turn or winding short circuits, or by surcharge, when two motors are electrically coupled for the same load. This fault is potentially serious because it produces an extra strong torque, and possibly an overheating of the stator, which can only appear in a part of the pole pairs. In other applications, such as in dynamic breaking, short circuits are directly applied to the motor terminals. Even though the motors can be designed for these applications, demagnetization of the machine can still occur [14].

Table 1 shows the characteristic features of the motor being studied. The stator and speed currents are measured in the vector control with q axis and position feedback (Fig.1) for a nominal torque at 6000 rpm, 4500 rpm, 3000 rpm, 1500, and 300 rpm. Figures 4 and 5 show the current of axes q and d for PMSM magnetized to 50% at 6000 rpm.

In the case of 6000 rpm there is a supply frequency of 300 Hz, for which the main rotor frequency is 100 Hz, due to its three pole pairs. The main harmonics concern the last frequency.

The shape of the q axis current wave shows an oscillation every 10 milliseconds, which correspond to the first rotor harmonic when each stator phase notices the demagnetization fault in the rotor demagnetized magnet.

p is the number of poles, Tl is the load torque, B is the damping coefficient, ω is the rotor speed and J is the moment of inertia.

In the most frequent control case, we can establish the direct axis current to zero, consider the magnetic flow constant in the air gap, and obtain an electromagnetic torque which is directly proportional to the axial current q [3-4]. Figure 1 shows a typical vector control scheme with position feedback and stator current feedback loop adjustment for PMSM. As has been pointed out, the general case uses a d axis current reference value of zero, to carry out the torque control only with q axis current. This vector control scheme is equivalent to breaking up the excitation in DC machines, and it allows for high control capabilities.

Figures 2 and 3 show q and d axis current for a healthy

Study on the Permanent Magnet Demagnetization Fault in Permanent Magnet Synchronous Machines

PMSM at 6000 rpm, operated with the previous control.

Fig. 1. Vector control scheme for PMSM.

Study on the Permanent Magnet Demagnetization Fault in Permanent Magnet Synchronous Machines