永磁同步电机永磁体抗去磁能力的研究
faults are quickly detected. Appropriate tracing of the misalignments, rotor ovality, bearing attrition, axial bending, variation of the current value in each phase of the machine malformation in the rotor magnetic core and magnetic
resonance at critical speeds [12]. In the case of dynamic enables fault detection between turns.
eccentricity, the longitudinal change of the air gap while the
B. Short circuit fault in the DC barrage. rotor turns transforms the stator winding inductances and the A short circuit at the exit of the DC bar or a short circuit resultant flow connections into frequency components of the fault in the DC condenser might appear. If so, the DC bar’s rotation frequency and its multiples. voltage decreases rapidly, followed by a long transient of the It is worth remarking that, in the case of speed increases in power supply, as the supply is short-circuited by the the event of dynamic eccentricity, the significance of the converter. Hence, the detection voltage drop in the DC bars fault harmonics in the stator current increases and the is enough to diagnose and report the fault. amplitude of these harmonics in the electromagnetic torque
diminishes [13].
C. Bearing Fault.
Under normal conditions, and after some time working, the F. Defects in the Permanent Magnet for PMSM parts might present fatigue, which increases the noise level Breakings or fissures in the permanent magnet cause the and the vibrations [6-7]. machine’s constant flow to decrease, create noise and It has been proved that, in induction machines, these vibrations due to the magnetic imbalance, and may lead to variations appear in the stator current with certain rotor disintegration in the case of high speeds. frequencies: rotation frequency function, number of poles, The highest demagnetization risk appears at low inside and outside diameter of the bearing ball, and contact temperature, when the residuary flow density is elevated and angle of the ball with its support or jacket [7]. the coercive power is low. That is the case in a machine with Some of the approaches for online detection of these faults high short circuit current, in which the magnet cannot resist use neuronal networks, such as those in [10]. Other solutions the demagnetizing volt-amperes. [11] propose a frequency – statistical adaptive time method, Previous studies [12-13] show that rotor faults appear in focused on the detection of bearing faults and in induction the harmonics which are induced into the stator current, at a machine cages. frequency equal to the rotating speed and in its multiples. These proposals require a perfect classification of faults. The present article introduces the analysis of the stator and Besides, the detection procedure requires extensive training zero sequence current harmonics or a PMSM motor which to achieve an accurate diagnosis. has partially been demagnetized and which operates at
nominal torque and different speeds.
D. Static Eccentricity.
II. VECTOR CONTROL OF THE PMSM. Eccentricities are normally permitted in the air gap due to
manufacturing tolerances. However, when the latter are The permanent magnet PMSM motor powered by a sufficiently elevated, the static and dynamic eccentricities triphasic sinusoidal supply induces electromotive sinusoidal produced are higher than expected and unbalanced radial force in the air gap, which produces a constant torque [3-4]. powers appear, which at the same time carry rotor shaft Taking into account the following assumptions, and applying inclinations, bearing fissures, etc. If these are not detected, the Park transform, we can obtain the model in the axes qd0 their effects can accumulate and cause greater damage to the produced by the equations (1) and (2): machine, and this can even lead to contact between the stator
The saturation effects are negligible. and the rotor [12].
The EMF induction is sinusoidal and balanced in the
In case of a fault due to static and dynamic eccentricity,
three phase system. the most important fault frequencies in the stator current
analysis are the synchronic frequency divided by the pole The losses due to parasitic and hysteresis currents are
negligible. pair and the multiples of the frequency, especially the
multiples 1, 3, 5 and 7 of the rotor frequency. There is no dynamic field current
Static eccentricity induces several air gaps in different
rotor points, which makes inductances in the three phases With these assumptions, the stator d, q equations of the different. These differences become clear in the direct, PMSM in the rotor reference frame are: inverse or zero sequence components of the current or
magnetic flow of the air gap. (1)E. Dynamic Eccentricity.
Dynamic eccentricity might appear following an
inclination of the rotor shaft, a misuse of the bearings or
[v]=[R][i]+ t[λ]+ωλ
qdo
qdo
qdo
qd
[v]=[v[i]=[i
Tqdo
Tqdo
q
q
vd
id
io
]
vo
]
Demagnetization Analysis of Permanent Magnet Synchronous Machines under Short Circuit Fault 隐藏>> Demagnetization Analysis of Permanent Magnet Synchronous Machines...
Influence+of+design+parameters+on__+cogging+torque+in+permanent+magnet+...Influence of Design Parameters on Cogging Torque in Permanent Magnet Machines ...
(cont’d) Transients or machine faults can lead to a worst-case demagnetization as shown which results in permanent demagnetization of the permanent magnet...
536. , “Comparative study of permanent magnet brushless machines [10] with...uence of design parameters on cogging torque in permanent magnet machines,”...
The Feasibility Study of Permanent Magnet Coupling Applied in Scraper Conveyor_理学_高等教育_教育专区。The Feasibility Study of Permanent Magnet Coupling ...
Researches on End Effects of Permanent Magnet Electromagnetic Launchers_天文/地理_自然科学_专业资料。201 3年 第1 3期 SCIENCE&TECHNOLOGY INFORMATION 0外语论...
Permanent Magnet Rotor Assembly_机械/仪表_工程科技_专业资料。永磁结构设计...magnets to have Br = 10 kG and a linear second quadrant demagnetization ...
Influence of Design Parameters on Cogging Torque in Directly Driven Permanent Magnet Synchronous_专业资料。今日推荐 50份文档 2014年注册会计师考试...
Localization for the Non-Invasive Detecting Capsule in GI Tract Utilizing Permanent Magnet and M_专业资料。维普资讯 http://www.cqvip.com Junlora ofDogu ...
Torque in Directly Driven Permanent Magnet Synchronous_机械/仪表_工程科技_专业...Sebastian. “Study of cogging torque in permanent magnet machines”. IEEE ...
热门文档