永磁同步电机永磁体抗去磁能力的研究
Study on the Permanent Magnet Demagnetization Fault in Permanent Magnet
Synchronous Machines
J. A. Rosero, J. Cusido, A. Garcia, J.A. Ortega, L. Romeral
MCIA Research Group
Universitat Politècnica de Catalunya
C. Colom 1. 08222 Terrassa
Catalunya. Spain
prevents the propagation of the fault and minimizes its impact in the converter’s DC bars and in the shaft torque. In the case of fault current due to a short circuit in the machine, this will be limited by the nominal value of the phase inductance, which, according to its design, must have high reactance, close to 1 p.u. The various faults which can appear in the converter, the electrical machine and the control system are the following [5-7]: Open circuit in the phases.
Short circuit in the phase terminals of the machine, I. INTRODUCTION
between winding turns.
There is a growing concern about fault tolerance in the
Fault in the DC bus capacity.
field of industrial systems and magnetic actuators, so that
operation is possible even in the event of some kind of fault Fault in the power supply system [8].
and hence continued service can be guaranteed in critical Fault in a position or speed sensor (the simultaneous
operation of multiple sensors and an indirect position applications, such as aerospace systems. Therefore, these
detection method guarantee continuity [8]). systems must abide by a number of characteristics that make
them more reliable and efficient [1]: Mechanical faults, such as static and dynamic
eccentricities, bearing damage and permanent magnet Design of distributed and modular systems, which
demagnetization. facilitate maintenance, supervision and updating with
In order to detect these faults, a number of diagnostic new technologies.
Highly efficient design for the entire speed range to methods are employed [4-7]:
optimize the use of the power supply. Electromagnetic field monitoring for the analysis of the
winding and of faults around the motor shaft (axial flow An improved electrical insulation between phases to
detection). prevent short circuits and to reduce faults in the inverter.
An improved magnetic and material insulation between Temperature measurement and infrared recognition.
phases to prevent fault propagation from one phase to Monitoring of acoustic noise and vibrations. the next, or to diminish the effect of thermal propagation Motor current signature analysis (MCSA). among phases in the event of a fault. Polisensorial models based on neuronal networks and on High winding inductances to confine short circuit artificial intelligence among others.
current in the event of a fault. Some of the most common faults appearing in PMSM An improved system capacity to operate uninterrupted motors and their control drives are specified in the following
and to thereby maintain service in the event of a fault sections. until its elimination or until replacement of the damaged
A. Short circuit fault between turns device.
These faults are related with isolation defects, and can be Present PMSM designs show a strong connection
between torque and inertia and operate with high power phase-to-phase, ground-to-phase or phase turn faults. Often, density and power factor, compared to induction the fault starts as a defect between turns and increases until it machines and salient pole synchronous machines, due to becomes a ground fault [6-8]. the lack of magnetizing current. PMSM can be highly The new designs applied to permanent magnet machines applied in robotic and aerospace application actuators, as should be able to operate continuously in the event of a short well as in automotive vehicles. [2-4]. PMSM control of circuit or with an open-phase circuit [9]. Furthermore, the an actuator must be designed to ensure the continuity of configuration of the power converter enables continuous the operation even in case of a fault in the unit and to operation in the event of an open circuit in the power device apply an appropriate action following the fault which and even with short circuits in the machine, as long as these
Abstract – This article studies the permanent magnet demagnetization fault in permanent magnet synchronous machines (PMSM). The study is carried out by analyzing the harmonics obtained using the Fast Fourier Transform (FFT) of stator and zero sequence currents at nominal torque for the whole range of machine operation speeds.
The appropriate combination of analyses on the different currents makes it possible to determine the faults for any speed range
Index Terms – PMSM drives, fault detection, Demagnetization.
Demagnetization Analysis of Permanent Magnet Synchronous Machines under Short Circuit Fault 隐藏>> Demagnetization Analysis of Permanent Magnet Synchronous Machines...
Influence+of+design+parameters+on__+cogging+torque+in+permanent+magnet+...Influence of Design Parameters on Cogging Torque in Permanent Magnet Machines ...
(cont’d) Transients or machine faults can lead to a worst-case demagnetization as shown which results in permanent demagnetization of the permanent magnet...
536. , “Comparative study of permanent magnet brushless machines [10] with...uence of design parameters on cogging torque in permanent magnet machines,”...
The Feasibility Study of Permanent Magnet Coupling Applied in Scraper Conveyor_理学_高等教育_教育专区。The Feasibility Study of Permanent Magnet Coupling ...
Researches on End Effects of Permanent Magnet Electromagnetic Launchers_天文/地理_自然科学_专业资料。201 3年 第1 3期 SCIENCE&TECHNOLOGY INFORMATION 0外语论...
Permanent Magnet Rotor Assembly_机械/仪表_工程科技_专业资料。永磁结构设计...magnets to have Br = 10 kG and a linear second quadrant demagnetization ...
Influence of Design Parameters on Cogging Torque in Directly Driven Permanent Magnet Synchronous_专业资料。今日推荐 50份文档 2014年注册会计师考试...
Localization for the Non-Invasive Detecting Capsule in GI Tract Utilizing Permanent Magnet and M_专业资料。维普资讯 http://www.cqvip.com Junlora ofDogu ...
Torque in Directly Driven Permanent Magnet Synchronous_机械/仪表_工程科技_专业...Sebastian. “Study of cogging torque in permanent magnet machines”. IEEE ...
热门文档