JESD22-A100-B_2000_Cycled_Temperature-Humidity-Bias_Life_Test

JESD

JEDEC Standard No. 22-A100-B

Page 4

4 Test Conditions (cont’d)

4.2 Biasing guidelines (cont’d)

4.2.3 Choosing and reporting – criteria for choosing continuous or cyclical bias, and whether or not toreport the amount by which the die temperature exceeds the chamber ambient temperature, aresummarized in Table 1:Table 1 — Cyclical Bias and Reporting Tja

Cyclical Bias?Report Tja? Tja

NoNo Tja < 5 °C, orPower per DUT < 200 mW

NoYes( Tja 5 °C, or

Power per DUT 200 mW)

and Tja < 10 °C

YesYes Tja 10 °C

5 Procedures

The test devices shall be mounted in a manner that exposes them to the specified temperature and

humidity with a specified electrical biasing condition. The test devices shall be placed in the test chamberwith the sample and chamber at room ambient temperature and humidity. Care shall be taken to minimizethe occurrence of condensation on devices and electrical fixtures.

5.1 Ramp-up and ramp-down

During ramp-up and ramp-down, condensation shall be avoided by ensuring that the test chamber (drybulb) temperature exceeds the wet bulb temperature at all times. The rate of temperature change shall notexceed

10 °C/minute. At all interim and final endpoint measurements, the chamber humidity and temperatureshall be reduced to room ambient conditions before removing the devices from the chamber.

5.2 Transition periods

During the transition periods from 65 °C to 30 °C and back up to 65 °C, the relative humidity may drop aslow as 80%. The chamber shall be vented to avoid artificial pressurization.

5.3 Test clock

The test clock starts at the beginning of the initial ramp-up and stops at the end of the final ramp-down.

5.4 Bias

Bias shall be verified after devices are loaded, prior to the start of the test clock. Bias shall also be verifiedafter the test clock stops, but before the devices are removed from the chamber.

Test Method A100-B

(Revision of A-100-A)

上一页第8页

你可能喜欢

热门文档

相关文档

  • JESD22-A100D-Cycled Temperature-Humidity-Bias Life ...

    JEDEC STANDARD Cycled Temperature-Humidity-Bias Life Test JESD22-A100D (Revision of JESD22-A100-C,October 2007) JULY 2013 JEDEC SOLID STATE TECHNOLOGY ...

  • JEDEC标准族

    JEDEC 工业标准 环境应力试验 [JDa1] JESD22-A100-B Cycled Temperature-Humidity-Bias Life Test 上电温湿度循环寿命试验, (Revision of JESD22-A100-A) ...

  • JESD22-A118

    Samples are subjected to a non-condensing, humid atmosphere, similar to the JESD-22-A101, "Steady State Temperature, Humidity and Bias Life Test", but...

  • JEDEC工业标准

    JEDEC 工业标准 环境应力试验 [JDa1] JESD22-A100-B Cycled Temperature-Humidity-Bias Life Test 上电温湿度循环寿命试验, (Revi...

  • JEDEC 100系列标准

    JEDEC STANDARD Cycled Temperature-Humidity-Bias Life Test JESD22-A100C (Revision of JESD22-A100-B, April 2000) OCTOBER 2007 JEDEC SOLID STATE TECHNOLOGY ...

  • IC可靠性测试项目及参考标准

    (High/ Low Temperature Operating Life)目的: 评估...JESD22-A113-D EIAJED- 4701-B101 评估结果:八...(Temperature Humidity Bias Test)目的: 评估 IC ...

  • SRF-1016Z中文资料

    humidity (autoclave), extreme hot and cold ...life testing as a DC biased elevated temperature ...JESD22-A110B -40°C to +85°C Cycled bias (...

  • SRF-2016Z中文资料

    humidity (autoclave), extreme hot and cold ...life testing as a DC biased elevated temperature ...JESD22-A110B -40°C to +85°C Cycled bias (...

  • SRQ-2116Z中文资料

    humidity (autoclave), extreme hot and cold ...life testing as a DC biased elevated temperature ...JESD22-A110B -40°C to +85°C Cycled bias (...

  • PCMC135T-1R0MF中文资料

    B Bias Current Source Test Condition Temperature :...a period (2) Vibration time : period cycled ...Humidity resistance Inductance change : Within ± ...

站点地图 | 文档上传 | 侵权投诉 | 手机版
本站所有资源均来自互联网,本站只负责收集和整理,均不承担任何法律责任,如有侵权等其它行为请联系我们.
文档下载 Copyright 2013 doc.guandang.net All Rights Reserved.  -  email