JESD
JEDEC Standard No. 22-A100-B
Page 5
5 Procedures (cont’d)
5.5 Readout
Electrical test shall be performed not later than 48 hours after the end of ramp-down. Note: For
intermediate readouts, devices shall be returned to the stress within 96 hours of the end of ramp-down.The rate of moisture loss from devices after removal from the chamber can be reduced by placing thedevices in sealed moisture barrier bags without desiccant. When the devices are placed in sealed bags, the“test window clock” runs at 1/3 of the rate of devices exposed to the laboratory ambient. Thus, the testwindow can be extended to as much as 144 hours, and the time to return to stress to as much as 288 hoursby enclosing the devices in moisture-proof bags.
5.6 Handling
Suitable hand-covering shall be used to handle devices, boards, and fixtures. Contamination control isimportant in any highly-accelerated moisture stress test.6 Failure Criteria
A device will be considered to have failed the Cycled Temperature-humidity-bias Life Test if parametriclimits are exceeded, or if functionality cannot be demonstrated under nominal and worst-case conditionsas specified in the applicable procurement document or data sheet.7 Safety
Follow equipment manufacturer’s recommendations and local safety regulations.8 Summary
The following details shall be specified in the applicable procurement document:
a) Test duration, if other than as specified in clause 4.1
b) Measurement after test
c) Biasing configuration
d) Temperature of die during test if it is more than 5 °C above the chamber ambient
e) Frequency and duty cycle of bias if cycled bias is to be used
Test Method A100-B
(Revision of A-100-A)
JEDEC STANDARD Cycled Temperature-Humidity-Bias Life Test JESD22-A100D (Revision of JESD22-A100-C,October 2007) JULY 2013 JEDEC SOLID STATE TECHNOLOGY ...
JEDEC 工业标准 环境应力试验 [JDa1] JESD22-A100-B Cycled Temperature-Humidity-Bias Life Test 上电温湿度循环寿命试验, (Revision of JESD22-A100-A) ...
Samples are subjected to a non-condensing, humid atmosphere, similar to the JESD-22-A101, "Steady State Temperature, Humidity and Bias Life Test", but...
JEDEC 工业标准 环境应力试验 [JDa1] JESD22-A100-B Cycled Temperature-Humidity-Bias Life Test 上电温湿度循环寿命试验, (Revi...
JEDEC STANDARD Cycled Temperature-Humidity-Bias Life Test JESD22-A100C (Revision of JESD22-A100-B, April 2000) OCTOBER 2007 JEDEC SOLID STATE TECHNOLOGY ...
(High/ Low Temperature Operating Life)目的: 评估...JESD22-A113-D EIAJED- 4701-B101 评估结果:八...(Temperature Humidity Bias Test)目的: 评估 IC ...
humidity (autoclave), extreme hot and cold ...life testing as a DC biased elevated temperature ...JESD22-A110B -40°C to +85°C Cycled bias (...
humidity (autoclave), extreme hot and cold ...life testing as a DC biased elevated temperature ...JESD22-A110B -40°C to +85°C Cycled bias (...
humidity (autoclave), extreme hot and cold ...life testing as a DC biased elevated temperature ...JESD22-A110B -40°C to +85°C Cycled bias (...
B Bias Current Source Test Condition Temperature :...a period (2) Vibration time : period cycled ...Humidity resistance Inductance change : Within ± ...