4 Test Conditions (cont’d)
4.2 Biasing guidelines
4.2.1 Apply bias according to the following guidelines:
a) Minimize power dissipation.
b) Alternate pin bias as much as possible.
c) Distribute potential differences across chip metallization as much as possible.
d) Maximize voltage within operating range.
NOTE — The priority of the above guidelines depends on the mechanism and specific device
characteristics.
4.2.2 Either of two kinds of bias may be used to satisfy these guidelines, whichever is more severe:
a)Continuous bias – the dc bias shall be applied continuously. Continuous bias is more severe than
cycled bias when the die temperature is less than or equal to 10 °C higher than the chamber
ambient temperature, or if the die temperature is not known when the heat dissipation of the
device under test (DUT) is less than 200 mW. If the heat dissipation of the DUT exceeds 200
mW, then the die temperature should be calculated. If the die temperature exceeds the chamberambient temperature by more than 5 °C, then the die temperature rise above the chamber ambientshould be included in reports of test results since the acceleration of failure mechanisms will beaffected.
b)Cycled bias – the dc voltage applied to the devices under test shall be periodically interrupted
with an appropriate frequency and duty cycle. If the biasing configuration results in a temperaturerise above the chamber ambient , Tja, exceeding 10 °C, then cycled bias, when optimized for aspecific device type, will be more severe than continuous bias. Heating as a result of power
dissipation tends to drive moisture away from the die and thereby hinders moisture-related failuremechanisms. Cycled bias permits moisture collection on the die during the off periods when thedevice power dissipation does not occur. Cycling the DUT bias with one hour on and one hour offis optimal for most plastic encapsulated microcircuits. The die temperature, as calculated on thebasis of the known thermal impedance and dissipation, should be quoted with the results
whenever it exceeds the chamber ambient by 5 °C or more.
Test Method A100-B
(Revision of A-100-A)
JEDEC STANDARD Cycled Temperature-Humidity-Bias Life Test JESD22-A100D (Revision of JESD22-A100-C,October 2007) JULY 2013 JEDEC SOLID STATE TECHNOLOGY ...
JEDEC 工业标准 环境应力试验 [JDa1] JESD22-A100-B Cycled Temperature-Humidity-Bias Life Test 上电温湿度循环寿命试验, (Revision of JESD22-A100-A) ...
Samples are subjected to a non-condensing, humid atmosphere, similar to the JESD-22-A101, "Steady State Temperature, Humidity and Bias Life Test", but...
JEDEC 工业标准 环境应力试验 [JDa1] JESD22-A100-B Cycled Temperature-Humidity-Bias Life Test 上电温湿度循环寿命试验, (Revi...
JEDEC STANDARD Cycled Temperature-Humidity-Bias Life Test JESD22-A100C (Revision of JESD22-A100-B, April 2000) OCTOBER 2007 JEDEC SOLID STATE TECHNOLOGY ...
(High/ Low Temperature Operating Life)目的: 评估...JESD22-A113-D EIAJED- 4701-B101 评估结果:八...(Temperature Humidity Bias Test)目的: 评估 IC ...
humidity (autoclave), extreme hot and cold ...life testing as a DC biased elevated temperature ...JESD22-A110B -40°C to +85°C Cycled bias (...
humidity (autoclave), extreme hot and cold ...life testing as a DC biased elevated temperature ...JESD22-A110B -40°C to +85°C Cycled bias (...
humidity (autoclave), extreme hot and cold ...life testing as a DC biased elevated temperature ...JESD22-A110B -40°C to +85°C Cycled bias (...
B Bias Current Source Test Condition Temperature :...a period (2) Vibration time : period cycled ...Humidity resistance Inductance change : Within ± ...
热门文档