对桥楼设备布置提供参考

MSC/Circ.982

ANNEX 5.3.6.3 Individual Lighting Adjustment (单独的调光器)

Page 15 Each device should be fitted with an individual lighting adjustment. In addition functional

groups of devices, displays and controls should be equipped with common light adjustment.

每个设备都必须配备单独的调光器,此外功能集成的设备,显示器及控制单元组应配备共用调光器。 5.4 Alarms (警报) 5.4.1

Alarm Management(警报管理)

5.4.1.1 Alarm Acknowledgement (报警确认)

A method of acknowledging all alarms (silence audible alarms and set visual alarms to steady state), including the indication of the source of the alarm, should be provided at the navigating and maneuvering workstation, to avoid distraction by alarms which require attention but have no direct influence on the safe navigation of the ship and which do not require immediate action to restore or maintain the safe navigation of the ship.

所有报警包括报警源的指示必须在驾控台上有确认设备(声音报警消音,光(视觉)报警消除闪烁),以避免那些仅要求引起注意而无需采取立即行动以恢复或维持船舶安全航行的警报信号对操作人员产生干扰。

5.4.1.9 Alarm Testing(报警测试)

Provision should be made for functionally testing alarms. 应为警报功能性测试提供测试大纲。

5.4.1.10 Power supply (电源供电)

Required alarm systems should be continuously powered and should have an automatic change-over to a stand-by power supply in case of loss of normal power supply.

规定要求的报警系统必须持续供电,并且在主电源失电的状态下能够自动切换至备用电源

5.4.1.11 Indication of Alarms (报警指示)

Alarms should be indicated in order of sequence and provided with aids for decision-making. An explanation or justification of an alarm should be available (on request).

应按一定秩序报警以便有助于采取一定的行动,如有要求,必须对警报信号进行一定的解释

I:\CIRC\MSC\982.doc

AL

L

RI

5.4.1.8 Alarm Minimization (警报最小化) The number of alarms should be minimized. 警报的数量应最小化。

G

H

T

5.4.1.7 Cancellation of Alarms (报警取消)

Alarms and acknowledged alarm should only be capable of being cancelled if the alarm condition is rectified. This cancellation should only be possible at the individual equipment. 如果警报状态需要调整,报警和报警确认应只能被取消。这种报警取消只能针对单个设备。

RE

SER

5.4.1.6 Acknowledgement of Alarms (报警确认) Alarms should be maintained until they are acknowledged. 所有报警必须一直维持直至确认。

VED

BY R

5.4.1.5 Alarm Status (报警状态)

Alarm systems should clearly distinguish between alarm, acknowledged alarm, and no alarm (normal condition).

报警系统应清晰区分警报状态,确认警报状态,及无报警(正常状态)

AD

5.4.1.4 Sensor Input Failure or Absence(传感信号输入故障或缺失) Alarms should be provided to indicate sensor input failure or absence. 传感信号输入故障或缺失应有报警。

IO

H

5.4.1.3 Failure or Reduction of Power Supply(电源故障或电压下降)

Alarms should be provided to indicate failure or reduction in the power supply which would effect the safe operation of the equipment.

对于影响设备安全操作的电源故障或电压下降应提供报警信号。

O

LL

AND

5.4.1.2 Fire and Emergency Alarms (火灾及紧急报警)

The alarm indicators and controls of the fire alarm and emergency alarm should be located at the safety workstation.

火灾及紧急报警的装置应安装在安全控制台上。