MSC/Circ.982 ANNEX Page 16

5.4.1.12 Presentation of Alarms (报警状态)

The presentation of alarms should be clear, distinctive, unambiguous, and consistent.

警报的显示必须清晰,独特,明确且一致。

5.4.1.13 Modes of Alarms (报警模式)

All required alarms should be presented through both visual and auditory means. 规定的警报必须以声光形式报警。

5.4.2 Visual Alarms (视觉警报) 5.4.2.1 Discrimination of Visual Alarms (视觉报警辨别)

Visual alarms should clearly differ from routine information on displays.

显示器上视觉报警应和常规显示信息有明显区别。

声音报警应区分于其他常规信号,如铃声,蜂鸣器及常规操作噪声。

5.4.3.4 Sound Characteristic (声音特性)

Under normal working conditions, the alarm signals should be heard properly inside the wheelhouse and outside on the bridge wings and their sound characteristics should not be inconvenient to the human ear.

正常工作状态下,在驾驶室内及两翼驾驶室外应正好听到警报,且警报声不应对人耳产生不适。

I:\CIRC\MSC\982.doc

AL

5.4.3.3 Focusing on Audible Alarms (声音报警要求)

Audible alarms should be differentiated from routine signals, such as bells, buzzers, and normal operation noises.

L

5.4.3.2 Audible Alarms (声音报警)

Audible alarms should go off upon acknowledgement. 声音报警确认后应消音。

RI

G

H

5.4.2.6 Night Vision (夜视力)

Visual alarms on the navigating bridge should not interfere with night vision. 驾驶室内视觉警报不应影响夜视力。

5.4.3 Audible Alarms (声音报警)

5.4.3.1 Use of Audible Alarms(声音报警)

Audible alarms should be used simultaneously with visual alarms. 声音报警应和视觉报警同步。

T

RE

SER

VED

BY R

5.4.2.5 Flash Rate (闪光频率)

Flashing visual alarms should be illuminated for at least 50 % of the cycle and have a pulse frequency in the range of 0.5 Hz to 1.5 Hz.

视觉闪光警报在每个报警周期内至少有50%时间点亮并且脉冲频率应在0.5赫兹至1.5赫兹。

AD

5.4.2.4 Presentation of Normal Conditions (No Alarm)(正常状态(无报警)

Alarm indicators should be designed to show no light in normal conditions (no alarm) or should be non-existent on displays.

报警指示应设计为在正常状态(无报警)状态下无灯光或在显示器上无显示。

IO

H

O

5.4.2.3 Presentation of Acknowledged Alarms (报警确认状态) Acknowledged alarms should be presented by steady display. 已确认的报警应停止闪烁。

LL

AND

5.4.2.2 Presentation of Visual Alarms(视觉报警)

Visual alarms should be flashing. The flashing display should change to steady display upon acknowledgement

视觉报警应闪烁,经确认后,闪光报警应停止闪烁。