 导航当前位置: 文档下载 > 所有分类 > 工程科技 > 环境科学/食品科学 > Developments of the Plasma-Enhanced Electrostatic Precipitator for Mercury Removal in Offgas
侵权投诉

Developments of the Plasma-Enhanced Electrostatic Precipitator for Mercury Removal in Offgas

PLASMA-ENHANCED ELECTROSTATIC PRECIPITATOR267

Developments of the Plasma-Enhanced Electrostatic Precipitator for Mercury Removal in Offgas

Figure 4.

Developments of the Plasma-Enhanced Electrostatic Precipitator for Mercury Removal in Offgas

28-slpm (1-scfm) central electrode configuration.

reactions are occurring, which reduces the mercury re-moval efficiency. Therefore, to achieve the required mer-cury removal efficiency, a reagent gas that is pollutantspecific must be used in place of oxygen.

In the process of determining a mercury selectivereagent gas, the published mechanisms thought to be re-sponsible for oxidizing elemental mercury in coal com-bustion flue gas were reviewed. Candidate reagent gascompounds are now being reviewed for testing. Factorsthat may influence the mercury oxidation rate include theconcentration and speciation of the mercury in the feedcoal, flue gas temperature and composition, concentra-tion and physical characteristics of the entrained ash, andthe length of time the reactants are entrained in the fluegas (Galbreath and Zygarlicke, 1996). As the flue gascools, a significant fraction of the vaporized mercury ad-sorbs onto residual carbon particles and on other parti-cles with a large surface area-to-volume ratio. Conse-quently, the speciation of mercury in flue gas appears toinvolve both gaseous and solid phases.

sonic orifice and dilution eductor to provide a reliableand consistent inlet mercury concentration to the PEESPtest cell. A hot cell within the mercury vaporizer containsa commercially available mercury permeation tube. Byaccurately controlling the temperature of the hot cell andthe permeation tube, a known and repeatable mass flowof elemental mercury vapor is eluted from the permeationtube. A 20-milliliter per minute (mL/min) nitrogen purge,controlled by a sonic orifice connected to the suction sideof a dilution eductor, is used to carry the elemental mer-cury vapor from the hot cell to the test bed. The motivefluid used in the dilution eductor is nitrogen at a flowrate of 4.5 liters per minute (L/min). To minimize the po-tential of amalgamating or condensing mercury vaporwithin the dilution eductor, the motive fluid is preheatedto 125°F (52°C) prior to entering the eductor. The targetconcentration for this sequence of testing is 10 g/dscm,which is typical for a coal-fired generator emission.

28-SLPM (1-SCFM) TEST BED

Figure 1 is a schematic diagram of the PEESP 28-slpm(1-scfm) test bed. Process streams supplying the test bedinclude oxygen, nitrogen, plant air, and plant service wa-ter. Bottled pollutant gases are mixed with oxygen, ni-trogen, and water vapor in a heated manifold to producea simulated flue gas with a nominal stream compositionof 71% nitrogen, 5% oxygen, 12% water, 12% carbondioxide (CO2), 20 parts per million volume (ppmv) car-bon monoxide (CO), 70 ppmv NO, and 100 ppmv SO2by volume. The temperature of the simulated flue gas en-tering the PEESP test cell (Fig. 2) is maintained at 300 °F (149°C). Water circulated through a cooling jacketmaintains the outlet temperature of the PEESP test cellat 100°F (38°C).

Elemental mercury vapor is added to the simulated flueFigure 5.End view of the central electrode showing thegas using a vaporizing system (Fig. 3) that implements acorona discharge.

ENVIRON ENG SCI, VOL. 22, NO. 2, 2005