Developments of the Plasma-Enhanced Electrostatic Precipitator for Mercury Removal in Offgas

268

The mercury concentration entering the PEESP testcell is measured at Sampling Port 1 (SP-1) using an on-line mercury analyzer.

The reagent gas flow rate to the PEESP test cell isnominally 0.06 slpm, which is approximately 0.2% of theprecipitator inlet flow rate. Reagent gases for this testcampaign are varied to evaluate mercury selectivity. Thereagent gas is radially injected into the flue gas from thecentral electrode (Fig. 4). As the reagent gas passesthrough the active zone of the corona discharge (Fig. 5),experimental evidence suggests that reactive species andradicals are formed that selectively oxidize the elemen-tal mercury vapor, which forms water-soluble com-pounds and fine particulate that are absorbed by the con-densing water droplets. In the electric field, the waterdroplets acquire a negative charge and are attracted to thegrounded positive electrode (reactor wall) where they areremoved from the system. The aqueous mercuric ions,thus formed, are collected on the electrode walls and re-moved as a liquid slurry.

The mercury removal efficiency of the PEESP test cellis determined by analyzing the gas exiting the precipita-tor at Sampling Port 3 and comparing the results to theinlet concentration measured at SP-1. Mercury mass clo-sure for the PEESP test cell is determined by analyzingthe liquid condensate for mercury and comparing the to-tal mass into the precipitator vs. the total mass out of theprecipitator.

Voltage and current meters attached to the power leadsare used to measure the power consumption of the PEESPtest cell. The high-voltage power supply used to powerthe PEESP test cell is capable of providing a maximumoutput voltage of 30 kilovolts (kV). By relating the pre-cipitator input power to the flow rate, scale-up informa-tion can be ascertained from the experiments.

A vane pump provides the motive force to draw theprocess gases through the test bed and to maintain thetest bed under a slight vacuum during testing. To protect

Table 1.

Mercury removal summary.

Mercury inlete

g/dscm

15.3315.3315.3315.3315.3315.33

Mercury outlet g/dscm

3.983.963.7212.301.9218.29

MONTGOMERY ET AL.

the pump from condensation and to prevent fugitive mer-cury emissions, a knockout trap and desiccant/carbontraps are installed downstream of the PEESP test cell.

TEST OBJECTIVES

The objectives for this phase of testing are to demon-strate the mercury removal capabilities of the 28-slpm (1-scfm) PEESP test cell using various reagent gases de-signed to selectively oxidize elemental mercury withoutaffecting the oxidation states of NO and SO2. To deter-mine the mercury removal efficiency of the PEESP tech-nology, inlet and outlet gas samples will be collected andcompared at various power levels up to 3 watts per stan-dard cubic foot per minute (W/scfm) using an on-linemercury analyzer. Three w/sfm minute correlates to thegenerally acceptable upper limit of power usage allowedfor a flue gas cleanup system (1% of power plant totalpower output).

TEST RESULTS

The composition of the coal-fired boiler simulated fluegas was nominally 71% nitrogen, 5% oxygen, 12% wa-ter, 12% CO2, 20 ppmv CO, 70 ppmv NO, and 100 ppmvSO2by volume and are not varied during testing. Not allcomponents of the simulated gas were tested at the timeof this writing, and oxygen was at 21%. To approximateresidence times typical of a WESP system, the processgas flow rate through the test cell was maintained at 28slpm (1 scfm). At an operating temperature of 300°F (149°C), the actual flow rate through the cell was ap-proximately 33.2 L/min. (1.2 actual cubic feet perminute). With the PEESP test cell having a cross-sec-tional area of 30.9 cm2centimeters (4.8 square inches)and a corona active zone of approximately 23 cm (9 in.)

Test runa,b,c,d

Average baseline run

Competitive reaction runs2Air

Air COAir NOAir SO2

Air CO NO SO2

Removal efficiencyf

74%74%76%20%87% 19%

aPower density 3 W/scfm; baverage inlet 15.33 g/dscm using average baseline offset data; cvoltage 20 kV; dNo electrode

reagent gas; emercury inlet corrected for sidewall collection offset; fefficiency inlet outlet/inlet.