Scaling Quad-Flat No-Leads Package Performance to E-band Frequencies

0.35 or 0.30 mm) is expected to expected to create opportunity

Scaling Quad-Flat No-Leads Package Performance to E-band Frequencies

for further bandwidth improvement.

Fig. 11. 0.5 mm (orig) vs 0.4 mm (new) pitch MCQFN – single-port response

VI. E-BAND TEST STRATEGIES FOR QFN PACKAGES MicroCoax QFN performance analysis presented so far included the transition from GCPW or microstrip of PCB into the QFN. Therefore, characterizing this QFN performance accurately, especially approaching 100GHz, requires soldering the QFN on the same PCB with the optimized transmission line and transition (as in Fig. 5). Fig. 12 shows a photo of a MCQFN E- test module with WR-12 waveguide connections. Reference test structures with same transmission line length and no QFN will be used for comparison and gated TDR method will be used to de-embed waveguide transition

Scaling Quad-Flat No-Leads Package Performance to E-band Frequencies

reflections.

Fig. 12. E-band MCQFN WR-12 test fixture

Testing MCQFN packaged RFICs in production may employ commercial GSG probes. Fig. 13 shows the bottom side of a QFN. Leveraging air εcutoff frequency for GSG probes, however the best r of about 1 enables higher performance will be reached with probe pitch smaller than /20 [9].100GHz GSG testing shall be no more than 150um to enable Launch pitch calculated using this rule of thumb for accurate non-calibrated testing. Calibration substrate BW is not guaranteed beyond 65-70GHz but perform reasonably up to E-band frequencies when maximum probe pitch is 200um. Hence, accurately calibrated GSG probing with larger pitches may not be achievable. Moreover probe pitch size is well related and inversely proportional to performance and BW. However, larger pitch sizes may be of value for production testing. Such larger pitch GSG probes and their test results can

be later correlated to test fixture (Fig.12) MCQFN results collected in characterization phase. Cascade model ACP-110-GSG-250 with 250um pitch offers less than 1dB loss and better than 15dBr to 100 GHz and may be used to launch 0.3mm pitch QFN with minimal performance degradation. GGB Industries offers pitch sizes up to 450um on 120GHz rated probes with Picoprobe model 120. Since ground and signal continuity are critical with both probe and DUT, minimal probe pitch capable of landing safely on the QFN leadframe is

Scaling Quad-Flat No-Leads Package Performance to E-band Frequencies

recommended for testing QFNs up to 100GHz .

Fig. 13. E-band QFN launch (GSG) configuration.

VII. CONCLUSIONS

MicroCoax enabled QFN packages show promise for devices operating at millimeter-wave frequencies. The approach has significant advantages over wafer level packaging commonly employed at frequencies beyond 50GHz with better signal isolation, thermal dissipation and easier integration with PCB. Data gathered to date on 0.5mm pitch MCQFN shows excellent performance up to 65 GHz. Extension of this technology up to E-band frequencies will require scaling down the of the QFN pitch and further reduction and optimization of discontinuity dimensions. Such pitch size scaling will further enable GSG probing of these packages in volume production to an acceptable level of accuracy.

REFERENCES

[1] S. S. Cahill, E. A. Sanjuan, and L. Levine “Development of 100+ GHz

high-frequency MicroCoax wire bonds”, IMAPS 2006

[2] S. S. Cahill, and E. A. Sanjuan “QFN-based Millimeter Wave Packaging

to 80GHz”, IMWS 2009

[3] M. Yu, R. Vahldieck, and K. Wu, “Theoretical and experimental

characterization of Coplanar Waveguide discontinuities”, IEEE 1638-1640

[4] M. Yu, R. Vahldieck, and K. Wu, “A moment method analysis for

Coplanar Waveguide Discontinuity Inductances”, IEEE Transactions on Vol. 41, No. 9, pp. 1638-1640

[5] T. Saad, Microwave Engineers Handbook Volume One, Jul 1972, pp.

95-98

[6] M. V. Schneider, “Microstrip dispersion,” Proc. IEEE, vol. 60, pp. 144-146, Jan. 1972

[7] “A Dispersion formula satisfying recent requirements in

Aug 1988, Vol.pp. 1246 - 1250

[8] R. Rimolo-Donadio, C. Schuster, X. Gu, Y. H. Kwark, M. B. Ritter

“Analysis and optimization of the recessed probe launch for High Frequency Measurements of PCB Interconnects”, 978-3-9810801-3-1/DATE08 © 2008 EDAA

[9] Cascade Microtech, “Upper Frequency recommendations for various RF

probes and pitches”, June 21, 2012