method and specify the hydraulic diameter L = DH in the Hydraulic Diameter field.
Inputs at Pressure Outlet Boundaries
Defining Static Pressure:This value will be used for subsonic flow only. Should the flow become locally supersonic, the pressure will be extrapolated from the upstream conditions. Remember that the static pressure value you enter is relative to the operating pressure
set in the Operating Conditions dialog box. ANSYS FLUENT also provides an option to use a radial equilibrium outlet boundary condition. To enable this option, turn on Radial Equilibrium Pressure Distribution. When this feature is active, the specified gauge pressure applies only to the position of minimum radius (relative to the axis of rotation) at the boundary. Note
that this boundary condition can be used even if the rotational velocity is zero. For example, it could be applied to the calculation of the flow through an annulus containing guide vanes. Note that the radial equilibrium outlet condition is available only for 3D
and axisymmetric swirl calculations.
Backflow Direction Specification Method:The default value for this field is Normal to Boundary, and requires no further input。
If you are modeling species transport, you will set the backflow species mass or mole fractions under Species Mass Fractions or Species Mole Fractions.
If you are modeling combustion using the non-premixed or partially premixed com-
bustion model, you will set the backflow mixture fraction and variance values.
If you are modeling combustion using the premixed or partially premixed combus-
tion model, you will set the backflow Progress Variable value.
If backflow occurs, the pressure you specified as the Gauge Pressure will be used as
total pressure, so you need not specify a backflow pressure value explicitly. The flow direction will be based on your specification of the direction vector.
Even if no backflow is expected in the converged solution, you should always set realistic values to minimize convergence di culties in the event that backflow does occur during the calculation. Default Settings at Pressure Outlet Boundaries
Wall boundaries can be either stationary or moving. The stationary boundary condition
specifies a fixed wall,
Heat Flux Boundary Conditions:You can define an adiabatic wall by setting a zero heat flux condition. This is the default condition for all walls.
Species Boundary Conditions for Walls:By default, a zero-gradient condition for all species is assumed at walls (except for species that participate in surface reactions), but it is also possible to specify species mass fractions at walls. If you are modeling species transport with reactions, you can, alternatively, enable a reaction mechanism at a wall by turning on the Reaction option and selecting an available mechanism from the Reaction Mechanisms drop-down list.
Reaction Boundary Conditions for Walls:you can indicate whether or not surface reactions should be activated for the wall. Note that a zero-gradient condition is assumed at the wall for

species that do not participate in any surface reactions.
Fluent用户手册_电力/水利_工程科技_专业资料 暂无评价
FLUENT 6.3 使用手册_IT/计算机_专业资料。Fluent 6.3.26的相关帮助文档翻译过来的使用手册Fluent 6.3 使用手册 FLUENT 6.3 使用手册 B.Case 和 Data 文件...
TG(fluent使用手册)_电子/电路_工程科技_专业资料 暂无评价
如何使用该手册 根据你对 CFD 以及 FLUENT 公司的熟悉,你可以通过各种途径使用该手册 对于初学者,建议如下: 为了对 FLUENT 的计算能力以及启动方式有所了解,最好...
? ? ? ? ? 本手册介绍 FLUENT 的使用方法,并附带了相关的算例。下面是本教程各部分各章节的简略概括。 第一部分: 开始使用: 描述了 FLUENT 的计算能力以及...
注意:在 Fluent 使用手册中 "grid" 和 "mesh"是具有相同所指的两个单词 图一:基本程序结构 我们可以用 GAMBIT 产生所需的几何结构以及网格(如想了解得更多可以...
Fluent UDF 高级应用技术培训的应用实例 5.ANSYS FLUENT 14.5 Battery Module Manual ANSYS FLUENT 14.5官方用户手册 6.FLUENT湍流模拟教程(EN).pdf 阐述了FLUENT...
fluent-v6.3-lect-08b-user-defined-functions_工学_高等教育_教育专区。...编译 (详细内容请参阅FLUENT用户手册中的介绍) UDF 代码被一次性编译成机器语言...
,具体操作请参考 Fluent 用户手册。 34 在 FLUENT 的学习过程中,通常会涉及几个压力的概念,比如压力是相对 值还是绝对值?参考压力有何作用?如何设置和利用它? ...
Solve->Animate->Define...,具体操作请参考 Fluent 用户手册。 34 在 FLUENT 的学习过程中,通常会涉及几个压力的概念,比如压力是相对值还是绝对值?参考压力有 ...
热门文档