wind power control and design
Application of Models of the Wind Energy Conversion System to Wind Power Dynamic Analysis Wu Xueguang Wang Weisheng Dai Huizhu Chen Yunping Electric Power Research Institute Qinghe, Beijing 100085, China
Abstract: Due to stochastic variation of the wind energy, the wind power connected to the grid is stochastic. As a result of, the voltage of the grid, particularly near wind fhn, is hctuant. Accordmg to the chamcterktics of the wind energy conversion syste,mWECS), a program inchding the models of the W C S was developed. The dynamic performances of the startup, shutdown, and running processes of the WECS and the front of the gust could be simulated and investqpted. In this paper, A typical WECS connected to a large system ( a t e bus) was simulated, and the relationships of the short circuit capacity (SCC) with the wind power penetration were investigated. The results showed that the SCC was one of important factors to affect the wind power penetration. The biger SCC of the network at the WECS connected, the larger wind power penetration. There was a maximum penetration level of the wind power to a SCC given. If the wind ii, power of the WECS had exceeded a lmt the grid voltage fluctuation would have been in excess of the allowable value of the grid, in severe case, the voltage would have been unstable. Keywords: Wind power, models, dynamics.
By the end of 1997, the total installed capacity of the wind power is about 166.6MW[IO] in China. Many middle- or Luge- scale wind power plants have been p h m n g and built in succession. With developing of the wind power, penetrations of the WECS connected to the grid increased continuously, some problems such as the voltage fluctuation, dynamic stability, and electric qualities were more and more serious. Therefore, the WECS impacts on the grid are more and more concerned, and yet, investigationsabout the WECS are just beginning owing to the infant of development of the wind power in China, on the other hand, have no right means to analyze and simulate the problems about the WECS connected to the grid.. Evidently, the whole WECS consists m d y of blade, hub, coupler and induction generator. It is much different from the normal hydro or thermal electric energy conversion system that as follows four aspects: (1) Stochastic wind energy Owing to the wind speed affected by the atmosphere temperature, pressure, humidity, dried degree, actives of the sun and the moon, and topogaphy of the wind fmn, etc., and the wind speed is stochastic and uncontrolled, and then, the wind energy, too. (2) Large inertial wind turbine Wind energy density is generally much low. For captunng wind energy as possible as, the wind turbine blade is very large. Usually, a typical commercial middle- or large- size wind turbine blade diameter ranges fkom 20 to 60 meters. Obviously, the wind turbine inertia is bigger. (3) Flexible coupling between the wind turbine and the induction generator Due to the low rotational speed of the wind tu
rbine, the wind turbine can not connected directly to the generator, and then, the torque of the wind turbine must be transferred by a gear box and coupler.
1 Introduction .
In recent years, there have been growing interest in utilizing the WECS for providmg electric power to meet the needs of the people’s life in many countries of the world. It wag the results of the modem science and technology, especial power electronic, and paying more attention to energy shortage and environment protection, etc. Wind power in China has been developed t a o certain scale.
0-7803-4754-4/98/$10.00
0 1998 IEEE
-1406-

W6)Grid integration of wind energy into power system_生产/经营管理_经管... ZnCl Demand side energy storage application NaS batteries, redox flow ...
Power Quality Improvement Using Grid Side Converter of Wind Energy Conversion System_计算机硬件及网络_IT/计算机_专业资料。Journal of Energy and Power ...
IEEE TRANSACTIONS ON ENERGY CONVERSION, VOL. 24,...models for predicting the power of a wind farm ...The SCADA system of every wind turbine collects ...
the wind power system used in this paper was ...series models the electrical grid [12], [13]....1. During the conversion of wind energy into ...
Design and control of a wind power station with...Power Electronics and Application 1997;2:723–8.... a variable speed wind energy conversion system. ...
Application of Wind Generation on Weak Networks Considering Potential System Limitations Due to_专业资料。Junlfnryn ornierg21)1—2 oraoEeg dwe gnen 028785 a...
It presents theoretical analysis, modelling and control of Wind Energy Conversion Systems (WECS) connected to an autonomous power system with hydrogen storage...
basic models of their equivalent power electronic...(WTs) The Wind Energy Conversion System includes ...IEEE Transactions on Industry Application MarcheApril...
Battery Energy Storage to Strengthen the Wind Generator in Integrated Power System_专业资料。JOURNAL OFELECTRoNISCINCEAND C E TECHNOLOG VOL.,9No.1MARCH 01...
The strongest observed winds on a planet in our solar system occur on ...Wind power is the conversion of wind energy into a useful form of energy...
热门文档