Static cyclic tests on lightly reinforced concrete shear walls

C.Greifenhagen,P.Lestuzzi/EngineeringStructures27(2005)1703–1712

Static cyclic tests on lightly reinforced concrete shear walls

1707

Fig.3.Reinforcementofspecimens.

Table3

PropertiesofthereinforcementType

fy(MPa)

4mmcoldformedbar6mmmildsteelbar

745504

fu(MPa)800634

y(mm/m)3.712.85

u(cm/m)2.9111.05

fufy

( )1.071.26

5.2.Testingprocedureandloadinghistory

Theinstrumentationofthespecimenswithforcetransducers,displacementtransducersanddeformetertargetsallowedustomonitorloads,in-planedisplacementsandstrainsontheconcretesurface,respectively.Theloadwasquasi-staticallyappliedinsmallincrementsuptoatargetdisplacementoratargetforce.Atthispointthedisplacementwaskeptconstantinordertocapturehigh-resolutionimages,measurecrackwidthsandrecordstrainsonthesurface.Theforcedecreasedduringthistimeby10%–15%.Finally,thespecimenwasgraduallyunloaded.Forceanddisplacementcontrolledloadinghistorieswereappliedinordertosimulateseismicactionsbyreversedstaticcyclicloading.SpecimensM1andM2werecycledat25,50,100,150kNbaseshearandanominalaxialforceof136kN(Fig.4).Twocycleswereappliedateachlevelofbaseshear.Thespecimenswerethensubjectedtothreecyclesat200kNbaseshearwhichwasneartothebaseshearatnominal exuralstrength.Becauseofthelimitedloadcapacityoftheactuators,furtherincreaseofthebaseshearwasnotpossible.Theverticalpost-tensioningforcewasthendecreasedto106kNandthespecimenwassubjectedtotwocyclesoflateralloading.Subsequently,theverticalpost-tensioningforcewasreducedto86kNandthespecimenwascycleduptofailure.SpecimensM3andM4weresubjectedtoconstantnominalaxialforcesof136and76kN,respectively(Fig.5).Thecyclicloadingregimeofthesespecimensincludedloadincrementsof25kN

Static cyclic tests on lightly reinforced concrete shear walls

up

Fig.4.Loadinghistoryofspecimens,(a)M1,(b)M2.

to75%ofthebaseshearatnominal exuralstrengthanddisplacementincrementscorrespondingtothetoplateraldisplacementat75%baseshearatnominal exuralstrength.5.3.Testresults

Theforce–displacementrelationshipsareshowninFig.6.Inadditiontotheobservedresponses,theplotsincludeabilinearapproximationoftheload–displacementcurveandthecorrespondingvaluesofductilityanddrift.TheobservedfailuremodesarealsoindicatedinFig.6.Thebilinearapproximationwasdeterminedbyextrapolatingtheobservedtoplateraldisplacementat rst