p is the density of the working fluid; g is the acceleration due to gravity; V is the volume of the gas cavity at pressure PO; PO o is the initial pressure (charge pressure) in the compensator; Pl is the pressure at the inlet of the intake line (atmospheric or suction pressure); d12 and d23 are the pipe diameters in sections 1-2 and 2-3; Ii2 and h23 are the lengths of these same sections;~'12 and~'23 are the local friction coefficients of pipe sections 1-2 and 3-4. For a cylindrical compensator 4,8 VoPo h23= rid23 1 1"1 p~ --~3 j '
(12)
wherep~= Pl - p g H"Y12Q2vis the minimum average air pressure in the compensator; H is the maximum allowable suction head of the pump; and Qav is the average flow rate of the pump. Because the length of the intake pipes of mud pumps is small, friction losses in them are neglected. Equation (8) shows that the variable component of the pressure is determined by three factors: the pressure P3 in the compensator, the inertial component in the second to last term in Eq. (8) due to the change in the fluid head in the compensator, and the inertial pressure component in the last term of Eq. (8). As can be seen from Eq. (9), the change in the pressure P3 is inversely proportional to the charge pressure, which is determined by the product V0Po, and directly proportional to the difference Q12 - Q5 - Q6 - QT. By solving the system of Eqs. (8)-(10), we can find the minimum value of VoP0 (the compensator charge) which provides an acceptable value of b3. Then the working volume of the compensator can be calculated from the condition -
VK= 1.2 VoPo/p~,
(13)
where the charge pressure P0 can be taken to be atmospheric for pumps operating without a head. The system of Eqs. (8)-(10) was solved on a computer for d12= 0.28 m, 112= 6 m, h23= 0.2 m, h= 1.5 m,~'12= 6.5, and~'23= 1.5, which correspond to the intake line of the N B T - 1 pump of the Volgograd Drilling Equipment Plant. The results showed that if V equals the volume obtained from various instantaneous and average pump flow rates for o one pump rotation[3], the pressure nonuniformity (33 falls within the range 0.03-0.04 (ifPo is atmospheric). Increasing Vo by a factor of 1.5-2 lowers 63 to 0.01-0.02. Computer calculations for the same intake-line param
eters show that the inertial pressure component, determined by the second to last term in Eq. (8), is insignificant and can be neglected. Equation (8) shows that the inertial pressure component P2 is independent of the compensator charge VoPo and that the inertial component determined by the last term of Eq. (8) can be very important (up to 0.01 MPa and greater). Here the pressure nonuniformity 62 exceeds the norms, although the oscillations in the pressure P3 might not. In this case the intake part of the pump often operates poorly because of an insufficient compensator charge. The inertial pressure component P2 can be decreased by increasing the coefficient A= k12+ k23, which increases when the fluid inertia decreases in sections 1-2 and 2-3 of the piping. However, change in the coefficient k12 is limited by the design parameters of the intake pipe. Therefore the main way to decrease the inertial pressure component in section 1-2 is to increase the coefficient k23 (i.e. to decrease the fluid inertia in the compensator) in order to obtain the required values of 62 and P2 min' The minimum pressure at point 2, which determines the effectiveness of an intake line with a compensator, can be found from the simplified equation
P2min= ( p l - - p g h - - Y l 2 Q 1 2 )
1----~-
~
x -dr
" --dt
+ dt ) '
(14)
where A is the ratio of the inertial pressure components in a line with a compensator to the analogous quantity in a line without a compensator: m=
k12~A
=
1 1+ (k23/k12)
(15) 245

Analyzing the effectiveness of an intake compensator for a piston mud pump (J).Chemical and Petroleum (3):243-247. Engineering,1995,31 (M [2] 许...