THZ探测相机
Video-rate THz Imaging Applications using a 384x288 pixel Camera
M. Bolduc, M. Terroux, L. Marchese C. Chevalier, L. Mercier, F. Duchesne, L. Gagnon, B. Tremblay, F. Généreux, J.-E. Paultre, H. Oulachgar, F. Provençal, Y. Desroches, F. Berthiaume, C. Alain, and A. Bergeron
INO, Quebec City, G1P 4S4 Canada
Abstract—Video-rate THz reflection imaging, at 450 GHz using a high-resolution INO 384x288 pixel camera core, of pills in blister packs further contained within their final commercial packages is reported. These results open the door to deployable real-time milliwatt range at radiation above 2.52 THz (<123 μm wavelength).
The INO IRXCAM-THz camera core featuring an THz cameras for see-through imaging applications, providing a tool for NDE quality control and security inspection of goods within their final packaging.
I. INTRODUCTION And BACKGROUND
T
HZ is an emerging field at the junction between optical and millimeter wavelengths. THz imaging systems have been previously developed to see through various objects. However, although some relevant see-through performances were obtained using scanning systems, the long acquisition delay was inadequate to foresee practical non-destructive evaluation (NDE) imaging applications.
Recent development of THz microbolometer focal-plane arrays (FPA) has shed new light on the possibilities of having practical compact imagers for real-time applications. Among these applications, NDE, quality control and security inspections of parcels are the most immediate candidates for this technology. These inspections are typically conducted in controlled production and inspection environments suitable for proper implementation of THz imaging systems. There is a large pool of THz-compatible products and parcels that are looking for a technology for inspection. Among various THz NDE imaging applications is the inspection of packaged objects. INO has been involved in the development of a high-sensitivity video-rate THz camera core and optics using microwatt range quantum-cascade laser (QCL) for such applications since 2009 [1-2].
The feasibility of a mail screening application was first demonstrated by Hu et al. using a CO2 gas THz laser at 2.52 THz and a QCL at 4.3 THz with 160x120 and 320x240 infrared FPA cameras equipped with a f/1 silicon lens [3]. More recently, Faist et al. performed real-time imaging of a small metallic blade concealed in plastic tape using a QCL at 2.8 THz and a 160x120 infrared FPA camera with 50μm pixel pitch equipped with a f/1 picarin lens [4]. A modified uncooled 320x240 THz FPA has been also used with QCL sources for real-time imaging of a reflected mirror through black smoke at 3.75 THz [5] and of biomedical samples having different concentrations of lectin and glycogen at 4.2 THz [6]. Finally, an uncooled amorphous silicon-based antenna-coupled microbolometer 240x320 THz FPA has been used for reflection imaging of explosive materials with a QCL at 2.55 THz [7]. It is important to note that all these experiments were performed using high average power in the
optimized 160x120 THz FPA with 52µm pixel pitch has previously shown high sensitivity with good image quality for real-time THz imaging of concealed objects using a low-power QCL source or a CO2 gas THz laser [8-10]. INO also recently developed a high-resolution, highly sensitive 384x288 THz FPA with 35µm pixel pitch combined with a custom-designed f/1 THz objective [11]. This camera can be used as a basic building block for video-rate NDE, quality control and security inspection applications.
In this paper, reflection imaging of pills in blister packs contained within their final packaging at ~450 GHz radiation (662.82 μm wavelength) with low average power of ~70µWatts is presented. This range of THz frequencies provides the ability to see through various types of packaging. To the best of our knowledge, this is the first report of video-rate THz imaging application performed with an uncooled camera at such a very long THz wavelength in the microwatt range.
II. EXPERIMENTS
Imaging experiments were performed using a tunable CO2 gas THz laser from Coherent at ~450 GHz (662.82 µm wavelength). The laser beam was collimated and then focused using two off-axis parabolic mirrors to expand the beam size. Illumination was made as flat-top as possible to improve the quality of the images acquired. A polyethylene lens was placed between the beam and the aluminum plate used to hold the blister pack in its packaging. A TPR-D-61.5 pyroelectric detector from Gentec EO with 1.5 mm detector diameter with an optical chopper at 25 Hz was used for power measurements.
The INO IRXCAM-384THz camera equipped with a highly resistive float zone silicon (HRFZ-Si) lens with an antireflective parylene-c coating optimized for a 662.82 µm wavelength was used for video-rate reflection imaging. The long-wave infrared irradiation component <40μm wavelength was eliminated using a long-pass diffusive filter located at the aperture stop of the objective.
III. RESULTS
Video-rate reflection imaging of various glossy-finished commercial hard-paper packages containing blister packs has been performed at ~450 GHz radiation using the uncooled camera core. Inside the hard-paper package, the pills are