文档下载 文档下载导航
设为首页 | 加入收藏
搜索 请输入内容:  
 导航当前位置: 文档下载 > 所有分类 > 高等教育 > 医学 > New+applications+for+noninvasive+cardiac
侵权投诉

New+applications+for+noninvasive+cardiac

CT 学习 英文资料

New+applications+for+noninvasive+cardiac

© Springer-Verlag 2007

Carsten Rist

Thorsten R. JohnsonChristoph R. BeckerNew applications for noninvasive cardiacimaging: dual-source computed tomography

Maximilian F. ReiserKonstantin Nikolaou

C. Rist (M.F. Reiser · K. Nikolaou

·) · T. R. Johnson · C. R. Becker ·Department of Clinical Radiology,University Hospitals – Grosshadern, Ludwig-Maximilians University,Marchioninistr. 15,

81377 Munich, Germany

e-mail: carsten.rist@med.uni-muenchen.deTel.: +49-89-70953620Fax: +49-89-70958832

Conflict of interest statement There are nosources of financial support nor conflict ofinterest to declare.

AbstractCoronary catheter angiog-raphy is considered to be the stan-dard of reference for the diagnosisof coronary artery disease (CAD)and the grading of coronary arterystenoses. Even with the establishedgeneration of 16- and 64-multisliceCT (MSCT) systems, with remark-able results reported for diagnosticaccuracy, a substantial number oflimitations remain, hindering full acceptance of the method as a stan-dard technique in the clinical cas-cade for CAD patients. Recently,dual-source CT (DSCT) with im-proved temporal resolution hasbeen introduced into clinical rou-tine, raising the hope that some ofthe earlier problems might be over-come. MSCTA with 64-slice CTscanners has successfully been vali-dated for the evaluation of clinicallyrelevant lumen reduction of thecoronary arteries with high negativepredictive values and for the simul-taneous assessment of pulmonaryembolism, coronary artery stenoses,and aortic dissection and aneurysmin patients with chest pain (“triplerule out”). However, certain limita-tions continue to exist including par-tial volume effects due to heavy cal-cium deposits in the coronary arterywall, impaired assessability of coro-

nary artery branches smaller than 2mm in diameter, and impaired assessability of patients with a highheart rate and/or arrhythmia. WhileMSCT has mainly been tested to de-tect obstructive CAD, an accurateassessment of regional and globalventricular function, as well as ofthe aortic and mitral valves, mightbe feasible using DSCT, since imagereconstruction is possible in virtual-ly any phase of the cardiac cyclewith a sufficiently high temporal re-solution. DSCT is a robust methodfor the evaluation of patients withhigher heart rates and arrhythmiasand, in most cases, obviates theneed for beta-blocker premedica-tion. While the evaluation of coro-nary artery stenoses will remain theprimary clinical indication for car-diac DSCT, a simultaneous and suf-ficiently accurate assessment of

global left ventricular functional pa-rameters, regional wall motion, andvalve assessment becomes feasiblewith a single scan.

KeywordsDual-source CT · Coro-nary CT angiography · Coronaryartery disease · Ventricular func-tional parameters · Wall motion ·Valve assessment · Multislice-CT

第1页

你可能喜欢

热门文档

相关文档

  • 第2章+纳米生物技术前沿-2

    for genomic applications in medicine, environmental monitoring and homeland ...? 无损(noninvasive)检测,其检测过程不会对被检 测的样品或对象产生损害; ...

  • 战略分析工具 分析方法-Penetration+Curve+

    Methodology BOS 6 Penetration Curves Applications of...? Validating/determining market growth for a new ... a relatively invasive and painful medical ...

  • Rockchip_RK3188_Specifiation_Detail_V1.2

    personal mobile internet device and other digital multimedia applications, and...Invasive and non-invasive debug Six separate power domains for every core ...

  • 无创血糖仪产品介绍1《Integrity-Applications》

    无创血糖仪产品介绍1《Integrity-Applications》_...invasive measurements daily Unlimited non-invasive ...New connector to increase reliability of PEC (...

  • Rockchip RK3168 DATASHEET_Brief-for

    of peripheral interface to support very flexible applications as follows : ?...Invasive and non-invasive debug One separate power domain for secondary core...

  • 2008职称英语理工A真题+答案

    their capacity to withstand invasive weeds : ...a completely new market for landscape contractors....6 At present, possible applications of the "grid...

  • Mono-N-carboxymethyl chitosan (MCC) and N-trimethyl...

    (TMC) nanoparticles for non-invasive vaccine ...Especially for the intranasal applications, following...Low molecular weight chitosan nanoparticles as new ...

  • 13-Logistics+excellence

    invasive surgery Logistic inefficiencies Increased ...new configurations, however within the existing ... - Integration of IT applications across entities ...

  • 欧洲EN PN指导

    non-invasive, relatively inexpensive and can be ... reviews the current applications and limitations ...patient should be monitored for cardiac activity. ...

  • G601

    New portable instrument for non-invasive, quick ultrasonic flow measurement ... fixed to the pipe by the QuickFix pipe mounting fixture Applications 业....

站点地图 | 文档上传 | 侵权投诉 | 手机版
本站所有资源均来自互联网,本站只负责收集和整理,均不承担任何法律责任,如有侵权等其它行为请联系我们.
文档下载 Copyright 2013 doc.guandang.net All Rights Reserved.  -  email