INSTALLATION MANUAL FOR CRYSTALLINE SOLAR PHOTOVOLTAIC MODULES Rev.G
Attach a separate conductor as grounding wire to one of the 4mm diameter grounding holes marked 'GR'
on the module frame with a set of M4 screw, cup washer, flat washer, tooth washer, and M4 nut . This is to ensure positive electrical contact with the frame.
Figure 6. Schematic drawing

for SPV module grounding
13. BYPASS DIODES AND BLOCKING DIODES
Partial shading of an individual module can cause a reverse voltage across the shaded SPV module. Current is then forced go through the shaded area by the other modules.
When a bypass diode is wired in parallel with the series string, the forced current will flow through the diode and bypass the shaded SPV module, thereby minimizing module heating and array current losses.
Currently, Trina Solar SPV modules are equipped with bypass diodes in the junction box. The diode type is 10SQ050(for RenHe junction box)or F1200D (for Tyco junction box 2-1394723-1& 1-1394723-8) or SL1010 (for Tyco junction box 1740699-6) or SL1515 (for Tyco junction box 1740971-1). Do not try to open the junction box to change the diodes even if it malfunctions. This should be done by qualified personnel only.
In a system that uses a battery, blocking diodes are typically placed between the battery and the SPV module output to prevent battery discharge at night.
Diodes that are used as blocking diodes must have a:
Rated Average Forward Current [IF(AV)] above the maximum system current at the highest module operating
temperature.
Rated Repetitive Peak Reverse Voltage [VRRM] above the maximum system voltage at the lowest module operating
temperature.
14. WARNING AND NOTES
SPV modules generate electricity when exposed to light. An array of many modules can cause lethal shocks and/or burn hazards. Only authorized and trained personnel should have access to the modules. To reduce the risk of electrical shock or burns, modules may be covered with an opaque material during installation to avoid shocks or burns. Do not touch live terminals with bare hands. Use insulated tools for electrical connections.
Use appropriate methods to mount SPV modules. A module falling from high place could cause death, injury or damage.
SPV modules have a pair of male and female waterproof connectors. For a series electrical connection, connect positive (+) connector of first SPV module to the negative (-) connector of the following module.
Do not short the positive and the negative of a single SPV module. Do not disconnect under load. Be sure connectors have no gap between the insulators. A gap can cause fire hazard and/or danger of an electrical shock.
Address: No.2 Trina Road, Trina PV Park, New District, Changzhou, Jiangsu, P.R. China
KX-TDA安装手册_manual_信息与通信_工程科技_专业资料。KX-TDA30/KX-TDA100...章节 6 安装 (Installation)— KX-TDA30 介绍安装 KX-TDA30 的工序。提供...
图 10 Main Rack 11 图 11 选择 IC200UDR040/140/440 图 12 Module Catalog...追日程序流程 15 表1 名称 E_Stop start Manual_Auto MorningSun_Contr ...
TM---Manual--TMG安装与配置手册_IT/计算机_专业资料。MS TMG安装与配置手册ForeFront TMG Manual Book Shanghai Redmaple ForeFront TMG Manual Book 1 前期准备...
atv61安装手册s_installation_manual_cn_v2_信息与通信_工程科技_专业资料。Altivar 61 异步电机变频器 0.37 (0.5 HP) ... 45 kW (60 HP)/200 - 240...
RVT Manual CN---中文版rvt新型安装手册_电子/电路_工程科技_专业资料。ABB 新版彩屏RVT样本RVT 功率因数控制器 RVT 安装和操作说明 目录前言 ......
10G OEO 使用手册manual-1_信息与通信_工程科技_专业资料。10G OEO 传输子...4 2. INSTALLATION AND CONNECTION 安装与连接 ... 4 ...
FSP180-60SPV中文资料_电子/电路_工程科技_专业资料。元器件交易网www.cecb2b... Manual selection Frequency: 47~63Hz Input Current: 7A (RMS) @115V AC,...
MTA-ADW-1 开关量控制使用手册Manual_V2.0_2010.10_电子/电路_工程科技_...安装尺寸图 6.MTA-ADW-1油门执行器 开关量控制使用手册 www.hesmor.de 目录...
Installation/SystemRequirements --- 3 怎样获得 怎样获得Ubuntu安装光盘 安装光盘...module=via_rhine multicast=yes port=MII speed=10MB/s *-network DISABLED ...
KNT-SPV01 光伏发电实训系统 使用说明书(2011 年...Module Catalog 对话框 (5)在如图 13 所示的 ...追日程序流程 15 表1 名称 E_Stop start Manual_...
热门文档