Determination of Synchronous Machine Parameters

Determination of Synchronous Machine Parameters Using Standstill Frequency Response Tests at Different Excitation Levels F. S. Sellschopp M. A. Arjona Instituto Tecnologico de la Laguna, Departamento de Ingenieria Electrica-Electronica Blvd. Revolucion y Calz. Cuauhtemoc s/n 27000 Torreon, Coah. Mexico. Abstract-The standstill frequency response (SSFR) experiment is a well-proved test procedure to extract synchronous machine parameters using a low-level excitation signal. Model parameters extracted from SSFR are assumed to To analyze an electrical device, a set of sinusoidal signals with different frequencies of constant magnitude must be generated; this analysis is called a 'frequency sweep." The set of stimulus- and response- sinusoidal signals, based in the time domain. anayze eanconvertdat shold be thenfrquenc FFT to eh susos i o domaif. Applyin te specific frequency can be used for this purpose.

be completely linear due to the small excitation level and incursion on the saturation curve. This research is concerned with the low-level region of the saturation curve, where SSFR

.

s

tests are applied, and the effects of the B-H curve excitations on the estimated model parameters; application of different levels of sinusoidal excitation signal allows moving into different positions on the B-H curve. To analyze the response signals from the SSFR tests, the test is carried out while the machine is at standstill and the d-axis armature winding is excited with a sweep of sinusoids of constant voltage considering the field winding in open and short-circuit. Signal responses are processed using the Fourier

synchronous generator considering different excitation levels where different parameter sets are estimated according to the excitation levels. Three low-level tests are applied separately at both axes; each test level is carefully applied for each axis to establish a similar magnetization level. Results of excitation level to evaluate the saliency effect for the salientexitation ou evalatefn pole synchronous-generator.

This paper shows results from SSFR tests applied to a

because it is a two-port network, whereas in the q-axis, only one transfer function is needed. Different order models were characterized. The estimated parameters demonstrate that their behavior is related to the non-linear low-level saturation-curve of the synchronous machine. Tests were performed on a 7 kVA, 220V, 60 Hz salient-pole synchronous generator. Index Terms-Parameters, SSFR, two-port model, three transfer funcions parmete estmatin, mgnetc

transform to extract information of magnitude and phase angle. Three transfer functions are required to characterize the d-axis

sauraton.between

I. INTRODUCTION The standstill frequency response (SSFR) test is a wellestablished procedure that allows high order model characterization of synchronous machines; it has become a standard method for the characterization of electrical machines[I]-[9]. In the past, expensive devices w

ere used to carry out this analysis. With the a*ival of powerful computers, specialized software and hardware, these tests can now be

the signals can differ in magnitude and phase angle. The experimental determination of the transfer function of complicated devices is one of the main characteristics of the frequency response test. Thus, the frequency response method is well-established in the study of electrical machines[11]-[9].

performed easily. The steady-state response of a linear system in the presence of sinusoidal stimuli is known as frequency response. The frequency of the response and stimulus signals is the same, but

The d-axis synchronous machine is considered as a two-port network. A network port is a pair of electrical terminals. In principle, Kirchhoffs laws can mathematically relate the output and inputf of aa two-port network. The relationship betwen the two-voltages, and two ns the four variables, two voltages, and two currents requires two linear equations. However, one must consider two independent and two dependent variables. The two-port network parameters obtained from the linear equations are different for each set of dependent and independent variables. These parameters are known as open circuit, short circuit, and hybrid parameters. Characterization of a two-port network is usually done by hybrid parameters due to analogy with traditional transformer theory, i.e., open and short-circuit tests. The two-port parameters are useful since they can be derived from input/output port test measurements. A two-port network can be seen in Fig. 1, where, VI, V2 and I,, 12 are nrimarv and secondary voltages ri g and currents respectively I

II. MODELING THEORY

12

Network Circuit Fig. 1. Two-port representation of a network.

Two-Po

1 -4244-0743-5/07/$20.00©2007 IEEE

1014

Determination of Synchronous Machine Parameters

第1页