美国NVLAP(全美实验室自愿认证计划)关于与国际标准化组织(ISO)的17025规范的接轨的备忘录。
September 14, 2005
MEMORANDUM FOR NVLAP Laboratories and Assessors
From: Warren R. Merkel
Chief, Laboratory Accreditation Program
Subject: NVLAP Transition to New Accreditation Requirements (ISO/IEC 17025:2005)
In May 2005, ISO published the revised standard ISO/IEC 17025:2005, General requirements for the competence of testing and calibration laboratories. The international laboratory accreditation community has adopted the 2005 version and has agreed to a two-year transition period to move from the requirements of the current (1999) version to the requirements of the 2005 version.
The purpose of this memorandum is to announce the transition plan and timeline that NVLAP will use to implement the requirements of the new edition of ISO/IEC 17025. Since the first edition of ISO/IEC 17025 referred to ISO 9001:1994 and ISO 9002:1994, which have been superseded by ISO 9001:2000, the second edition of ISO/IEC 17025 was written to align ISO/IEC 17025 with ISO 9001:2000. In the second edition, clauses have been amended or added only when considered necessary for alignment.
NVLAP accreditation requirements, which include clauses 4 and 5 of ISO/IEC 17025, are published in NIST Handbook 150, NVLAP Procedures and General Requirements, clauses 4 and 5 and annexes A and B. NIST Handbook 150 is undergoing revision to incorporate the new edition of ISO/IEC 17025 and will be released in the near future.
In the meantime, NVLAP is making information about the new requirements available to you, so that you may prepare for the transition. Accordingly, we are sending to you the attached 2005 edition of the NIST Handbook 150 Checklist (formerly called the "General Operations Checklist"). The checklist has been annotated to identify new or changed requirements that are considered significant; minor changes in terminology have not been annotated. To download an electronic version of the checklist, please visit the Assessor Resources page of the NVLAP web site <doc.guandang.net;, where this document is available in both Adobe PDF and Microsoft Word formats.
To assist you with identifying and understanding the requirement changes in ISO/IEC 17025, we have attached a summary document entitled "Changes to ISO/IEC 17025." This summary is available in electronic format on the NVLAP web site.
understanding of the requirements of ISO/IEC G 65 and ISO/IEC 17025 13/...transition period that can be applied by all IAF ABs; related to ...
IEC17025 实验室认可 苏州瀚蔚企业管理咨询有限公司 管理培训 Management training...includes training and documents transition if the edition of standard revises;...
中国民用航空飞行校验中心的校准和检测实验室体系符合 ISO/IEC17025 标准的要求,...Transition 与 ILS 一致性 Coincidence With ILS 5.2 进近灯光检测结果 Testing...
laboratories that are in compliance with ISO/IEC 17025 and specific VCCI ...If a specifier/regulator imposes a different transition period, this will ...
Confidential Information GL认证实验室 In the style of DIN EN ISO/IEC 17025...Determination of glass transition temperature (DSC) 玻璃化转变温度测试 ? ...
Abbotsford BC, Canada V4X 2E7 SCC ISO/17025 (CAN-P-4E) Accredited ... the lower limit shall apply at the transition frequency METHOD OF ...
QS 9000, VDA6.1, ISO 13485, TL 9000, ISO 17025, SA 8000, OHSAS, ...Argentina's three-phase product certification process is in the transition ...
(1994.12 Revision C) Glass Transition Temperature and Z-Axis Thermal ...CNAS L3089 第 9 页共 11 页 ISO/IEC 17025 认可证书 CNAS-PD19/06-A/...
ISO/IEC 17025 认可证书 CNAS-PD19/06-A/2 中国合格评定国家认可委员会认可...2 Plastics 9 Oxygen index 0315 10 Glass transition temperature 0315 11 0315...
(ISO-17025 accredited) calibrations within 3 years of purchase* TRN-LLM-1...Determining the transition temperature of superconductive materials ? I-V ...
热门文档