Table 1. Composition, desorption properties, and lattice parameters of single-phase perovskites.

Avg.Weight Avg. Weight Weight loss Lattice

Nominal Composition

Loss vs. T Loss vs. Atm upon reduction Parameter (Å)

YSZ (3%) 0.470% 0.0955% N/A N/A Y0.1Sr0.9Co0.9Fe0.1O3-δ (YSCF1991) La0.1Sr0.9Co0.9Ni0.1O3-δ (LSCN1991) La0.1Sr0.9Co0.8Ni0.2O3-δ (LSCN1982) La0.1Sr0.9Co0.9Mn0.1O3-δ (LSCM1991) La0.1Sr0.9Co0.8Mn0.2O3-δ (LSCM1982) La0.1Sr0.9Co0.7Mn0.3O3-δ (LSCM1973) La0.1Sr0.9Co0.9Cr0.1O3-δ (LSCCr1991) La0.1Sr0.9Co0.9Fe0.1O3-δ (LSCF1991)

HIGH-TEMPERATURE OXYGEN SEPARATION

1.38% 1.21% 1.37% 1.36% 1.13% 0.949% 1.15% 1.45%

0.892% 0.624% 0.730% 0.707% 0.780% 0.910% 0.699% 0.624%

13.66% 13.98% 14.16% 14.00 12.99% 10.40% 12.99% 13.51%

3.840 3.847 3.847 3.845 3.844 3.841 3.868 3.852

Figure 2. Powder x-ray diffraction pattern of La0.1Sr0.9Co0.7Mn0.3O3-δ (a) after sintering at 1250 ºC and (b) after multiple-cycle TGA. The bottom pattern is a reference of a perovskite with the space group Pm-3m.

(silver-palladium) is used to ensure good electrical contact between the wires and the sample. The samples are placed in a tube furnace under controlled temperature and atmosphere. Measurements are being made in the 400º to 800 ºC range. A DC current source is connected to the wires at the ends of the sample and voltage drop across the other two wires is measured with a voltmeter. The conductivity is then simply determined from the current, voltage and the geometry. The initial measurements for each sample are done in air. Materials with high conductivity (comparable to that of the YSZ reference material) are measured in other pO2 atmospheres (e.g., UHP Ar and 3% hydrogen in Ar) to determine whether the conductivity is ionic or electronic: ionic conductivity will be independent of the oxygen pressure while electronic conductivity will scale with it. For materials of interest, AC measurements (impedance spectroscopy) will also be performed to learn more details about the mechanism of conductivity. In addition, a high temperature permeation unit is under construction to test the oxygen permeation properties of these materials at 850 ºC under an oxygen partial pressure differential. The unit will be connected to a residual gas analyzer (RGA) to monitor the permeate.

Conclusions

Double-substituted perovskites, A1-xSrxCo1-yByO3-δ (A=Y, La; B=Fe, Ni, Cr, Mn) were synthesized for use as ceramic high-temperature oxygen separation membranes. Preliminary results show the materials have promising oxygen sorption properties and are structurally robust under varying temperatures and atmospheres. Continuing work will focus on conductivity and permeation measurements, as well as stability under reaction conditions of H2SO4, SO2, and H2O at high temperatures.

Acknowledgement. Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the US DOE’s NNSA, contract DE-AC04-94-Al85000. The authors would like to thank John Heald for the acquisition of the x-ray data and Dr. Fred Gelbard and Dr. Terry Guilinger for their helpful discussions.

References

(1)Brown, L.; Besenbruch, G.; Lentsch, R.; Schultz, K.; Funk, J.; Pickard, P.; Marshall, A.; Showalter, S. High Efficiency

Generation Of Hydrogen Fuels Using Nuclear Power; Grant No. DE-FG03-99SF21888; Technical Report prepared for the Nuclear Energy Research Initiative (NERI) Program: December 2003. (2)Yang, Z.; Lin, Y.; Zeng, Y., High-temperature sorption process for air separation and oxygen removal. Ind. Eng. Chem. Res. 2002, 41, (11), 2775.

(3)Jade 6.5+, 6.5+; Materials Data Inc.: Livermore, CA, 2002. (4)Rodriguez-Carvajal, J. FullProf.2k, 2.60; ILL: 2004.

Prepr. Pap.-Am. Chem. Soc., Div. Fuel Chem. 2004, 49(2),842