外骨骼的很不错的国外论文
D Safety Aspects
The stoppers are attached for each motion to prevent the exceeding of the movable range for safety. The stoppers for pronation/supination motion are shown in Fig. 3 (b). In addition, the maximum torque of the exoskeleton is limited by the software. Furthermore, each motor has an individual switch and there is an emergency stop switch beside the exoskeleton.
IV POTENTIAL CONTROL METHODS
command was automatically switched to off value (0V)

from its on value (1.5V).
The proposed exoskeleton can be controlled based on the skin surface EMG signals or the force/torque sensors signals or both skin surface EMG signal and force/torque sensors signals.
EMG signals can be obtained from muscles of flexor carpi radialis, flexor carpi ulnaris and palmaris longus (weak flexor) for wrist flexion, muscles of extensor carpi radialis
Fig. 5 Experimental setup longus, extensor carpi radialis brevis and extensor carpi
ulnaris for wrist extension, muscles of extensor carpi
ulnaris and flexor carpi ulnaris for wrist ulnar deviation and The experimental results of on-off control for each muscles of extensor carpi radialis longus, extensor carpi individual motion and the combined motions are shown in radialis brevis and flexor carpi radialis for wrist radial Fig. 7 (a) and (b), respectively.

deviation. Muscles of pronator teres, pronator quadratus and anconeus can be used to obtain EMG signals for forearm pronation motion and muscles of biceps (proximal part) and extensor carpi radialis longus for forearm supinaton motion.
The amount of the force/torque generated between the user and the robot can be measured by the three axis force sensor and strain gauges.
V
EXPERIMENT
The experiments have been performed with a healthy male subject (28 years old) to confirm that the exoskeleton is able to make the required motions. Experimental setup is shown in Fig. 5.
The experimental set up consists of three motors with encoders, a personal computer with an interface card (JIF-171-1), two motor drivers (each has two channels) and power suppliers. Torque commands have been applied to the motor drivers according to the desired motions. Motor drivers actuate the motors according to the given torque commands. The rotations of the motors are measured from the encoders and fed back to the personal computer via the interface card.
In the first experiment, on-off (bang-bang) control of the robot was performed by providing desired torque command throughout the movable range, limited by software stoppers. When each link of the robot reached to its limit of movable range provided by software stoppers, the motion was automatically stopped. Figure 6 shows the movable range of pronation motion. The software stopper for the pronation motion was set at an angle of 58o. When the pronation motion reached to its software limit the torque
Fig. 6 Movable range of pronation motion
In the second experiment, sinusoidal motion was applied as the desired motion of each joint and proportional-derivative (PD) control was applied to control the motion of the exoskeleton.
Figure.8 shows the experimental results of each individual motion and Fig 9 shows the experimental results of combined motions.
The generated motions were flexible and smooth enough to apply for daily activities. When the human subject wore the robot and used it to perform given motions even for a long duration, he did not feel any pain or any fatigue. The robot is convenient to use for assisting wrist motions.
热门文档