文档下载 文档下载导航
设为首页 | 加入收藏
搜索 请输入内容:  
 导航当前位置: 文档下载 > 所有分类 > IT/计算机 > 计算机软件及应用 > 6.5_SAN_CLINET
侵权投诉

6.5_SAN_CLINET

simultaneous streams of data from its disks, that the same 8 streams of

data are transported across the SAN, and finally that they are written

simultaneously to the Server disk. Each one of those steps should be

profiled.

Do you have available processor time?

Transporting data at high speeds from the frontend disks to a backend

Fibre Transport requires a non-trivial amount of CPU usage. For example, a 600 MB/s Fibre transfer on a Linux 64 bit client requires 1.2 GB/s of

system I/O to both read from the application disks and write to the Fibre

Transport. This can consume almost 3ghz of the system's processors. If

the Fibre Transport service has to compete with an application for

processor cycles, it may have an impact on performance.

7.6 SAN Client service can not start in a timely manner on Windows

SAN Clients.

On some Windows configurations, the default service timeout of 30 seconds is insufficient time for SAN Client to initialize and load. Specifically, when a

system has many large boot time services or has limited resources, the client may timeout and fail to start the "SAN Client Fibre Transport Service" When this occurs, back ups cannot use Fibre Transport unless the client is started manually.

To workaround this timeout, increase the timeout to a value that gives the SAN Client service enough time to startup. In the Windows registry of the SAN Client, edit the following key:

\\HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\ServicesPipeTimeout

This key describes the service timeout in milliseconds. Set the value to

REG_DWORD = 90000, which increases the timeout to 90000 milliseconds.

7.7 My Solaris FT media server does not use all of the target mode

cards.

On Solaris systems (prior to 10 update 7), NetBackup 6.5.2 and later detect the PCI bus and only allow ports on one bus to be used for target mode, as follows: The first choice is the bus with the most 2312 target mode ports.

If there are no 2312 target mode ports, the bus with the most 24xx target mode

ports is used.

Target mode ports on other busses are not used.

7.8 I've updated my NetBackup release but I can't use new Fibre

Transport features.

If the Fibre Transport server was installed prior to the NetBackup update, drivers for the new release must be reinstalled in the operating system driver directories.

上一页第12页

你可能喜欢

热门文档

相关文档

  • 网络存储讲义

    (Server/Clinet)模式,到今天的网络计算(Network Computing)环境,今后的移动计算(...数据存储和数据备份 第一部分 网络存储技术目前的网络存储技术有SAN、NAS和iSCSI...

  • 曙光存储 DS8340简明手册

    (即直接将管理软件安装在曙光天阔 A950r-F 数据库服务器上,通过 FC SAN 管理...“SANtricity Storage Manager Clinet”运行 SANtricity 存储管理软件,出现如图 6-...

  • 网络存储介绍-含DAS-NAS-SAN的区别

    网络存储介绍-含DAS-NAS-SAN的区别_计算机硬件及网络_IT/计算机_专业资料。...(Server/Clinet)模式,到今天的网络计算(Network Computing)环境,今后的 移动计算...

  • IBM数据中心存储解决方案

    数据中心存储解决方案.存储区域网(SAN) IBM 数据中心存储解决方案.存储区域网(...从计算机的发展历史来看,从最早的服务器 /客户机(Server/Clinet)模式,到今天的...

  • 网络存储技术及其备份与容灾

    (Server/Clinet)模式,到今天的网络计算(Network Computing)环境,今后的移动计算(...数据存储和数据备份 第一部分 网络存储技术目前的网络存储技术有SAN、NAS和iSCSI...

  • 15-数据存储技术

    (Server/Clinet)模式,到今天的网络计算(Network Computing)环境,今后的移动计算(...SAN网络架构 SAN的特性 SAN更适合网络关键任务的数据存储,与其 他存储技术相比,...

  • 数据存储技术概述

    (Server/Clinet)模式,到今天的网络计算(Network Computing)环境,今后 的移动计算...对等资源共享 SAN网络架构 SAN网络架构 SAN存储系统五大组成 SAN存储系统五大组成...

  • VMware vSphere5.0安装实施步骤

    现在就可以使用vSphere clinet连接vCenter了。 第 30 页 1.4. VMware vCenter...后保存到目标存储, 该目标存储通过的存储设备如: 本地存储, ISCSI, SAN, NFS...

  • VMware vSphere 5.1 虚拟机管理

    使用 WEB Clinet 管理虚拟机 七、 使用 workstation 9.0 管理虚拟机 以上的...硬盘添加到虚拟机时, 您可创建虚拟磁盘、 添加现有虚拟磁盘或添加映射的 SAN ...

  • SANTricity操作手册

    点击“开始”->“程序”->“SANtricity Storage Manager Clinet”,出现如图2-...第一种方式是通过SANshare Storage Partitioning Wizard 完成,点击菜单项Mapping ...

站点地图 | 文档上传 | 侵权投诉 | 手机版
本站所有资源均来自互联网,本站只负责收集和整理,均不承担任何法律责任,如有侵权等其它行为请联系我们.
文档下载 Copyright 2013 doc.guandang.net All Rights Reserved.  -  email