6.5_SAN_CLINET

Is there a valid license for the SAN Client feature on the Master Server?

SAN Client is a separately licensed feature which requires a key called

“SAN Client” on the Master Server.

Are there Server entries for the SAN Client on the Master Server?

Remove any 'SERVER=clientname' entry in the Master Server for the

SAN Client. If the Master Server believes the SAN Client is also a Server,

it might shutdown the SAN Client.

Have you restarted the Client Service?

Although the SAN Client will be started on reboots of a server, it will not

automatically start up after you run the 'bpclntcmd' command. You must

run the client startup script, or use the Service Manager in Windows, to

start the SAN Client service.

7.2 The Fibre Transport services does not start up

Are there any marked QLogic Target ports in the server?

The 'nbftsrvr' and 'nbfdrv64' processes will exit if the system has no ports

available for Target Mode use.

Is there a valid license for the SAN Client feature on the Master Server?

SAN Client is a separately licensed feature which requires a key called

“SAN Client” on the Master Server. The Fibre Transport server performs

a license check during startup.

Was a reboot required for the installation of the Fibre Transport Server?

All Solaris installations require that the Media Server be rebooted after the

install of Fibre Transport in order to load the Fibre Transport drivers on

the marked target ports. In addition, Linux servers need to be rebooted if

you elected to not unload the existing QLogic drivers during the

installation of Fibre Transport.

7.3 My SAN Client is not discovering devices from my Fibre

Transport Servers

Is your Fibre Transport Server running?

SAN Clients can not discover the devices from a Fibre Transport server

unless the service is running on the Media Server. Verify the 'nbftsrvr'

and 'nbfdrv64' processes are active on the Media Server.

Are your Clients and Servers properly zoned?

Use the SAN Fabric configuration software to verify that your SAN

Clients and the Fibre Transports they use are contained in the same zone.

Verify that all the respective ports are online.

Have you followed the Fibre Channel discovery techniques outlined in

section 6?

There are several different configuration steps necessary for performing

Fibre Channel Discovery on an Operating System level. Please view the

上一页第10页

你可能喜欢

热门文档

相关文档

  • 网络存储讲义

    (Server/Clinet)模式,到今天的网络计算(Network Computing)环境,今后的移动计算(...数据存储和数据备份 第一部分 网络存储技术目前的网络存储技术有SAN、NAS和iSCSI...

  • 曙光存储 DS8340简明手册

    (即直接将管理软件安装在曙光天阔 A950r-F 数据库服务器上,通过 FC SAN 管理...“SANtricity Storage Manager Clinet”运行 SANtricity 存储管理软件,出现如图 6-...

  • 网络存储介绍-含DAS-NAS-SAN的区别

    网络存储介绍-含DAS-NAS-SAN的区别_计算机硬件及网络_IT/计算机_专业资料。...(Server/Clinet)模式,到今天的网络计算(Network Computing)环境,今后的 移动计算...

  • IBM数据中心存储解决方案

    数据中心存储解决方案.存储区域网(SAN) IBM 数据中心存储解决方案.存储区域网(...从计算机的发展历史来看,从最早的服务器 /客户机(Server/Clinet)模式,到今天的...

  • 网络存储技术及其备份与容灾

    (Server/Clinet)模式,到今天的网络计算(Network Computing)环境,今后的移动计算(...数据存储和数据备份 第一部分 网络存储技术目前的网络存储技术有SAN、NAS和iSCSI...

  • 15-数据存储技术

    (Server/Clinet)模式,到今天的网络计算(Network Computing)环境,今后的移动计算(...SAN网络架构 SAN的特性 SAN更适合网络关键任务的数据存储,与其 他存储技术相比,...

  • 数据存储技术概述

    (Server/Clinet)模式,到今天的网络计算(Network Computing)环境,今后 的移动计算...对等资源共享 SAN网络架构 SAN网络架构 SAN存储系统五大组成 SAN存储系统五大组成...

  • VMware vSphere5.0安装实施步骤

    现在就可以使用vSphere clinet连接vCenter了。 第 30 页 1.4. VMware vCenter...后保存到目标存储, 该目标存储通过的存储设备如: 本地存储, ISCSI, SAN, NFS...

  • VMware vSphere 5.1 虚拟机管理

    使用 WEB Clinet 管理虚拟机 七、 使用 workstation 9.0 管理虚拟机 以上的...硬盘添加到虚拟机时, 您可创建虚拟磁盘、 添加现有虚拟磁盘或添加映射的 SAN ...

  • SANTricity操作手册

    点击“开始”->“程序”->“SANtricity Storage Manager Clinet”,出现如图2-...第一种方式是通过SANshare Storage Partitioning Wizard 完成,点击菜单项Mapping ...

站点地图 | 文档上传 | 侵权投诉 | 手机版
本站所有资源均来自互联网,本站只负责收集和整理,均不承担任何法律责任,如有侵权等其它行为请联系我们.
文档下载 Copyright 2013 doc.guandang.net All Rights Reserved.  -  email