IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, VOL. 31, NO. 1, FEBRUARY 1990
91
Letters to the Editor
Analysis of a Static Power Converter Under Unbalance: A Novel Approach PRASAD N. ENJETI, MEMBER, IEEE, AND PHOIVOS D. ZIOGAS, MEMBER, IEEE Abstract-A general analysis procedure for a static power converter by the transfer function approach is presented. This method provides for closed-form expressions for all harmonics under balanced and unbalanced operating conditions. An example illustrating the effectiveness of this approach is given. Input (port)
i
!
Ve
(dc)
output (port)
Fig. 1. General three-phase ac-to-dc static power converter.
I. INTRODUCTION With the present-day advancement in power semiconductors and related circuit topologies, power control via static power conversion can be applied in speed control of dc motors, front-end dc link converters for variable frequency inverters, the utility interface of photovoltaic/fuel cell power systems, and high-voltage dc (HVDC) transmission. The implicit assumption in nearly every converter analysis presented in technical literature has been that the converter operates under balanced conditions (input voltage and gating signals). Evaluation of real operating conditions, however, shows that this assumption is false in nearly every case[3]. Due to an increase in the application of these converters, the effect of unbalance operation and the assessment of harmonics generated is important. It is a recognized fact that static power converters generate uncharacteristic harmonics on both the ac and dc sides under unbalance[ 11-[3]. The uncharacteristic harmonics referred to here are those harmonics that are absent during balanced or normal operation. The principle causes for the generation of uncharacteristic harmonics can be attributed to unbalance in three-phase supply voltages (both in magnitude and in phase) and converter switching angle errors. The serious repercussions of the appearance of uncharacteristic harmonics include signal interference and relay malfunctioning, overvoltages and excessive currents from resonance to harmonic voltages or currents in the network, excessive losses in terms of heating in rotating machines, an increase in distortion of the output voltage (dc) due to the appearance of a second harmonic component, and errors in induction-type kWh meters. The analysis presented in the assessment of harmonics generated by static power converters under unbalance involves computing the Fourier components of each harmonic via computer simulation. Thus, there is a lack of straightforward methods for computing uncharacteristic harmonics. This letter presents a novel analysis procedure for computing uncharacteristic harmonics under unbalance by suitably decomposing the converter transfer function into positive Manuscript received August 28, 1988; revised May 16, 1989. P. N. Enjeti is with the Department of Electrical Engineering, Texas A&M University, College Station, TX 77843. P. D
. Ziogas is with the Department of Electrical Engineering, Concordia University, Montreal, Canada. IEEE Log Number 893042 1.
and negative sequence components. The method provides for closedform expressions for all harmonics and therefore contributes to a better understanding of static power converters. Unbalance in voltage magnitude and phase angle and errors in switching angles can be easily incorporated into the analysis. Finally, an example illustrating the effectiveness of the approach is presented. 11. CONVERTER TRANSFER FUNCTION T Describing the input/output behavior of an exact mathematical description for a static power converter (shown in Fig. 1) in terms of a transfer function will be very useful. More specifically, a converter transfer function can be used to compute a dependent variable in terms of its respective independent variable. For example, the output voltage V, (dependent output) depends on both the converter transfer function and the input phase voltage V (independent input). That is
The converter transfer function vector T is composed of three independent switching functions (in a three-phase case, see Fig. 2):
For steady-state analysis, a Fourier series representation of each switching function is convenient and is given by m
SW,= m=l m
Am sin rn(wt+a)
(3)
SW*= m=l m
Am sin r n ( w t - 2~/ 3+ a )
(4)
SW3= m=l
Amsin r n ( w t+ 2~/ 3+ a )
and the input voltage V is given by I=
[ 51[ =
v .V sin(wt-2,/3] . sin wt V
. sin (wt+ 2~/ 3
0278-0046/90/02OO-OO91$01 .OO
0 1990 IEEE

analysis of induction motors under conditions of ...(HP ) is composed of static head (HS ), ...nitions of voltage unbalance,” IEEE Power Eng. ...
under distorted grid conditions such as unbalance and frequency vari鄄 1 引...Analysis of the LLC Se鄄 ries Resonant Converter [ A]援 Proceedings of ...
Under Grid Faults and Grid Voltage Unbalance ...converter only manages the rotor power, it can ...analysis of its behavior during grid and LVRT ...
analysis of two-level converter based on double ...unbalance control and how to restrain the ...under the static coordinate system, and simplified...
A numerical study of a torque converter with ...It has a role of transferring power from an ...(1995a) ‘Measurement and analysis of static ...
In this paper, Railway Static Power Conditioner [ R P C ) , a new system f o r reducing voltage unbalance and fluctuation, is described. To reduce...
Converter for Wind Power Generation ABSTRACT The ...result verify the theoretical analysis and the ... unbalance; Multi-loop control 目第一章 1.1 ...
Team 11893_ An Analysis of the Future ...shortage and unbalance distribution in power demand...As shown above, here we give a static upper ...
[10–12] studied static and dynamic performances ...unbalance responses and stability analysis of the ...Under the assumption, the Reynolds equation of Y...
power compensation, harmonic filter,static ...unbalance d reactive power of low-voltage power ... With four-leg converter designed as the main ...
热门文档