CONTROL OF MERCURY EMISSIONS
FROM COAL-FIRED ELECTRIC UTILITY BOILERS
Air Pollution Prevention and Control Division
National Risk Management Research Laboratory
Office of Research and Development
U.S. Environmental Protection Agency
Research Triangle Park, NC
Introduction
During combustion, the mercury (Hg) in coal is volatilized and converted to elemental mercury (Hg0) vapor in the high temperature regions of coal-fired boilers. As the flue gas is cooled, a series of complex reactions begin to convert Hg0 to ionic mercury (Hg2+) compounds and/or Hg compounds (Hgp) that are in a solid-phase at flue gas cleaning temperatures or Hg that is adsorbed onto the surface of other particles. The presence of chlorine gas-phase equilibrium favors the formation of mercuric chloride (HgCl2) at flue gas cleaning temperatures. However, Hg0 oxidation reactions are kinetically limited and, as a result, Hg enters the flue gas cleaning device(s) as a mixture of Hg0, Hg 2+, and Hgp. This partitioning of Hg into Hg0, Hg 2+, and Hgp is known as mercury speciation, which can have considerable influence on selection of mercury control approaches. In general, the majority of gaseous mercury in bituminous coal-fired boilers is Hg2+. On the other hand, the majority of gaseous mercury in subbituminous- and lignite-fired boilers is Hg0.
Control of mercury emissions from coal-fired boilers is currently achieved via existing controls used to remove particulate matter (PM), sulfur dioxide (SO2), and nitrogen oxides (NOx). This includes capture of Hgp in PM control equipment and soluble Hg 2+ compounds in wet flue gas desulfurization (FGD) systems. Available data also reflect that use of selective catalytic reduction (SCR) NOx control enhances oxidation of Hg0 in flue gas and results in increased mercury removal in wet FGD.
Table 1 shows the average reduction in total mercury (HgT) emissions developed from EPA’s Information Collection Request (ICR) data on U.S. coal-fired boilers. Plants that employ only PM controls experienced average HgT emission reductions ranging from 0 to 90 percent. Units with fabric filters (FFs) obtained the highest average levels of control. Decreasing average levels of control were generally observed for units equipped with a cold-side electrostatic precipitator (CS-ESP), hot-side ESP (HS-ESP), and particle scrubber (PS). For units equipped with dry scrubbers, the average HgT emission reductions ranged from 0 to 98 percent. The estimated average
reductions for wet flue gas desulfurization (FGD) scrubbers were similar and ranged from 0 to 98 percent.
As seen in Table 1, in general, the amount of Hg captured by a given control technology is greater for bituminous coal than for either subbituminous coal or lignite. For example, the average capture of Hg in plants equipped with a CS-ESP is 36 percent for bituminous coal, 3 percent for subbituminous coal, and 0 percent for lignite. Based on ICR data, it is estimated that existing controls remove about 36% of the 75 tons of mercury input with coal in U.S. coal-fired boilers. This results in current emissions of 48 tons of mercury.
2)Economic and Social Council of UN, Control of mercury emissions from coal-fired electric utility boilers, EB.AIR/WG.5/2002/6. 4 July, 2002. 四、...
Advanced Emissions Control Development Program- Mercury Control_教育学/心理学...emissions from coal-fired electric utility boilers sponsored by the Department...
The Demonstration of EPRI’s TOXECON Process to Control Mercury Emissions From Coal-fired Utility Boilers Steven Derenne, Principal Engineer; David Michaud,...
Foundation items: Program of the Electric Power ...Mercury emissions from coal-fired boilers can be ...The major problem for mercury control systems is ...
Mercury emissions from a coal-fired power plant... Central Research Institute of Electric Power ...ciency of pollution control devices might affect ...
Control technologies 2 Electric Power Industry ? $...Mercury in Coal-fired Boilers Entrained PM CO2 ...reduce mercury emissions from waste-toenergy ...
Total gaseous mercury emissions from mercury-enriched soil in Guizhou, China_专业资料。维普资讯 http://www.cqvip.com V12Sp120 o.5(up.06) CHNS RL0 ...
control flyash, and stack emissions, shows that ...Special attention is given to mercury, its ...from oil and coal-fired utility boilers on a ...
t existing coal-?red power plants with control ...to US NOx emissions from various sources in 2007...red electric utility boilers. Journal of Air and...
from EEA, 2010) 17 Mercury emissions in Europe...2010年数据) Coal fired power plants and boilers:...? Development of technologies for mercury control ...