
Talanta58(2002)387–396
doc.guandang.net
Internalsolidcontactsensorforthedeterminationofdoxycyclinehydrochlorideinpharmaceuticalformulation
XianXiangSuna,HassanY.Aboul-Eneinb,*
DepartmentofChemicalEngineering,JiangsuInstituteofPetrochemicalTechnology,
Changzhou213016,People’sRepublicofChina
b
PharmaceuticalAnalysisLaboratory,BiologicalandMedicalResearchDepartment,(MBC-03-65),KingFaisalSpecialistHospitalandResearchCentre,P.O.Box3354,Riyadh11211,SaudiArabiaReceived28December2001;receivedinrevisedform29May2002;accepted30May2002
a
Abstract
Theinternalsolidcontactsensorforthedeterminationofdoxycyclinehydrochloride(DC)wasdevelopedbasedonaconductingpolypyrrole(PPy) lmimmobilizedonaglassycarbonelectrodesurfacecastedbyaplasticizedpolyvinylchloride(PVC)membranecontaininganion-paircompoundofDCwithtetraphenylborate(TPB)anddibutylphtha-late(DBP)asplasticizer.Effectsofvariousfactorsfortheelectropolymerizationofpyrroleoraniline,includingmonomerconcentration,acidityorinorganicsaltandthicknessofpolymer lmwereinvestigatedexperimentally.ItwasfoundthattheslopeandthelinearrangeofSCSschangedwithboththedifferentconcentrationofmonomerandofKClinelectrolytesolutionandwiththedifferentsubstratematerialandamarkedin uenceofthechangeofsolutionpHonthepotentialresponseofsensoroccurredwhensamplesolutionpH\3.5.UndertheconditionofpH2.8,thesensorshowedanear-NernstianresponseovertherangeofDCconcentrationof1.0×10 2–1.0×10 5moll 1withtheslope(at25°C)of54.4mVperdecade.Thedetectionlimitobtainedwas4.0×10 6moll 1.ThesensorwassuccessfullyappliedtodeterminationofDCinpharmaceuticalformulation.©2002ElsevierScienceB.V.Allrightsreserved.
Keywords:Solidcontactssensor;Doxycycline;Potentiometry;Pharmaceuticalanalysis
1.Introduction
Ionselectivesensors,includingionselectivemembraneelectrodes,havebeenbecomingoneoftheeffectiveandpowerfulmeansforanalyticalscientistsinthedeterminationofdrugsubstancesandareplayinganincreasingroleinpharmaceuti-*Correspondingauthor.Fax:+966-1-442-7859
E-mailaddress:enein@kfshrc.edu.sa(H.Y.Aboul-Enein).
calanalysis[1–3],duetoofferingadvantagesofsimplicity,rapidityandaccuracyovermoreestab-lishedpharmaceuticalanalysismethods.More-over,theinterestindevelopingsmallsensingdevicesforbiomedicaluseisgrowingrapidly[4].Thekeyproblemassociatedwithdevelopmentofsmallorminiaturizedionselectivesensorsusedforinvivoassayofdrugsandforthedetermina-tionofdrugina owsystemishowtoeliminateaninnerreferenceelectrode,e.g.Ag/AgCl,to-
0039-9140/02/$-seefrontmatter©2002ElsevierScienceB.V.Allrightsreserved.PII:S0039-9140(02)00292-8
Internal solid contact... 暂无评价 10页 免费 Comparison of chemilum... ...SENSOR FOR THE DETERMINATION OF AMOXICILLIN Wan Fuwei, Yu Jinghua, Dai Ping...
New ion-pair based all-solid-state surfactant sensitive sensor for potentiometric determination of c 表面活性剂表面活性剂隐藏>> 843 Full Paper New Ion-...
A novel sensor using an in-situ solid auxiliary phase for the determination of SO, is reported in this paper. A Na,SO,-NASICON couple is interfaced ...
for the determination of_天文/地理_自然科学_专业...The major disadvantages of this sensor are the ...After the sample solution had been in contact ...
Solidphasemicroextractionforthedeterminationofiodinated_能源/化工_工程科技_专业...To each sample, 1,2dibromopropane as an internal standard (2 ml of a ...
nanomaterials used as solid catalysts are not consumed during the sensing ...The present sensor has been used for the determination of propionaldehyde in...
sensor for the determination of Hg(II) in water was fabricated by the ...was corrected using the C 1s level at 284.6 eV as an internal standard...
for the determination of artemether and DHA in_...Their solution was to develop a solid phase ... and the 2 stable isotope labelled internal ...
The Photolithography Process for Optical Sensor Semiconductor Physics & Devices Long Channel Devices G S Diffusive motion Current 1.2 1 0.8 Gate Short ...
57–63 Sensor for directly determining the ...internal combustion engines without increasing fuel ...determination is of special interest for Diesel ...
热门文档