web-based AQIS are presented by [9,10]. The use of the III. SYSTEM DESIGN AND IMPLEMENTATION new emerging technologies: internet, geographic mark-up

language (GML), and observation and measurement A. Automated Monitoring Station models to construct an interoperable repository for air Figure 2 shows an automated monitoring station quality sensors measurements are examined. located at the IMROH, in the northern residential part of

The aim of this paper is to present the main Zagreb .

functionalities of a specialized information system developed at IMROH for reporting air pollution data. We will take a look at its users, software applications, and at its future potential.

II.

USER REQUIREMENTS SPECIFICATION

The information system used at the Institute for

Medical Research and Occupational Health includes three groups of users:

Croatian Environment Agency (CEA user)

IMROH users

External users over the Web.

Figure 2. Connection between the automated measuring station and the IMROH server

The CEA user has access to the Institute's server that contains data exchange files downloaded every hour to CEA information system for air quality. IMROH users have access to a database containing information related to air pollutants. The data are obtained from measurements according to IMROH accredited methods (i.e. date, time, average, maximum and minimum mass concentration for particular pollutant). These data are later used for intercomparison with data obtained at other stations, for scientific research, and for reporting about air quality in Zagreb. External Web users have open access to air pollution data presented as graphs and numerical values and updated on the hour. In the future, information to external Web users will be available in the form of an archive, the air quality indicators (according to list of national air pollution indicators suggested by CEA) and prediction model in combination with raster images of the Zagreb City. According to all mentioned air-related legislation and based on specified user requirements the conceptual model of system architecture is created as shown in Figure 1 shows the system architecture.

It monitors an area within the radius of 2000 m.

It was established in 2009 to monitor traffic pollution and is part of the local air quality monitoring network. According to Decisions 97/101/EC and revised 2001/752/EC on Exchange of Information [3], the station type is defined in relation to the dominant emission sources influencing the air pollutant concentrations at the station. Pollutants monitored at the station are nitric oxide (NO), nitrogen dioxide (NO2), sulphur dioxide (SO2), ozone (O3), and carbon monoxide (CO) [3]. Meteorological parameters such as air temperature, relative air humidity, wind direction and speed are also monitored. The automated station incorporates automated analyzers which are connected to the station computer also connected to the Institute's server [see Fig. 2]. B. System Components

The information system consists of several components as follows:

a) Client (Interface)

Data measured by analyzers are collected using

the IDA Data Acquisition Application HR 2000, installed on the computer of the automated measuring station. The application records current mass concentration of gaseous pollutants, calculates hourly averages, and stores them into the database. The application can also produce time-series diagrams with daily averages and tables reporting average, maximum and minimum mass concentrations, as well as calibration data for each device connected to the computer.

b) Application Server and Web Server

The role of application server plays an

automated station computer containing all the applications needed for the efficient work of the automated station. The Web server is a database server processing all air-related data obtained from the automated monitoring station.

一个自动化网络系统的空气质量监测

Figure 1. Three-tier architecture of the information

一个自动化网络系统的空气质量监测

system at the IMROH

上一页第2页

你可能喜欢

  • 空气质量监测方案
  • 环境空气质量监测
  • 空气监测
  • 瓦斯监控系统
  • 综合自动化系统
  • 质量报告
  • 自动监测系统
  • 研究性学习结题报告

热门文档

相关文档

  • DOAS环境空气质量自动化监测系统运行维护

    DOAS系统与其他环境空气自动 化监测系统 相同, 是一套区域性空气质量的实时监测网络, 由 若干个自动监测子站、 中心计算机控制室、 质量保 证实验室和系统支持...

  • 国内外自动空气质量监测系统质量保证与质量控制方法的...

    网络化程度都有比较明显的差异,两国环境空气质量自动检测系统的基本 构成如图所示: 图1.1a 中国环境空气质量自动检测系统基本构成图 图1.1b 英国环境空气质量自动...

  • 基于无线传感器网络的空气质量检测系统

    2009年第3期 工业仪表与自动化装置 ?109? 基于无线传感器网络的空气质量监测...与传统的空气 质量监测系统相比,使用传感器网络进行环境监测 1监测系统的体系结构...

  • TH-2000系列环境空气质量自动监测系统

    TH-2000 系列环境空气质量自动监测系统由一个中心站和若干个子站组成,子站的数据采集控制系统 与中心站的数据处理控制系统通过通讯网络进行数据传输,完成数据采集处理...

  • 空气质量监测系统

    空气质量监测系统——CPR-KA 城市级大气环境自动监测...系统将在环境监控中心安装一个视频显示屏及建立一个... 结合国 际上成熟的电子技术和网络通讯技术研制、 ...

  • 教案1环境空气质量自动监测系统

    1. 环境空气质量自动监测系统 1.1 概述 1.1.1 建立系统的必要性和目的 随着我国城市建设和经济的高速发展,不可避免地带来了生活、工业和交通排放废气量的增 ...

  • 环境空气质量自动监测系统[1]

    环境空气质量自动监测系统[1]_经管营销_专业资料。环境空气质量自动监测 仪器简介《TH-2000型环境空气质量自动监测系统》。 主要部件包括TH-2001氮氧化物分析仪、 ...

  • 空气质量监测系统技术方案4[1].0-THY-修改

    空气质量自动监测系统数据无线发射方式 技术方案 生产单位:北京泰华恒越科技发展...AQM60 系列一.前言 环境保护监测先行,自动化、信息化是做好环境监测的前提和...

  • 基于无线传感网络的空气质量监测系统设计

    一种方法,本文 介绍了传感器在空气质量检测方面的原理应用及监控系统的网络设计...预计将在消费类电子设备、家庭智能化、工控、医用设备控制、农业自动化等领域获得...

  • 环境自动监测系统网络化改造与质量控制技术监督方案探讨

    22 No. 1 Feb. 2006 环境自动监测系统网络化改造与 质量控制技术监督方案探讨吴宇光摘 ( 厦门市环境监测中心站, 福建 厦门 361004) 要: 随着网络技术的发展与...

站点地图 | 文档上传 | 侵权投诉 | 手机版
本站所有资源均来自互联网,本站只负责收集和整理,均不承担任何法律责任,如有侵权等其它行为请联系我们.
文档下载 Copyright 2013 doc.guandang.net All Rights Reserved.  -  email