好文章
minimum in the T C vs. concentration isotherm (21)-correctly describes the data obtained. However, it seems unlikely that so many compounds would show maxima or minima in nitrogen but none of them would do so in Ar or CO,, while they do give positive and negative responses in these gases. One possible alternative explanation is that a concentration gradient is established in the cell as a result of thermal diffusion between the cell wall and the hotter filament. This could result in a transfer cf thermal energy across the gradient, the so-called Dufour effect ('7). If so, it should be possible to eliminate this effect by increasing the tu1 bulence in the cell. Preliminary investigation with such a cell indicates that this is so. The lack of W peaks and the low cost of CO, suggest that it would be a better carrier gas than nitiogen for preparative work (and possibly even some analytical work). Some workers have reported collecting samples in CO, by freezing it to dry ice (9). Also, the wide variation in response values (positive and negative) might be useful for qualitative analysis of pure compounds. Further work with COz and other carrier gases of low T C is planned.
ACKNOWLEDGMENT
The authors thank Floyd Fredricks for obtaining some of the data.
LITERATURE CITED
(3) Dal Piogare, S., Juvet, R. S., Jr.,"Gas Liquid Chromatography," p. 192, Interscience, New York, 1962;( (4) Dreisbach, R., compiler, Physical Properties of Chemical Compounds," 3 Vols., American Chemical Society, Washington, D. C., 1955, 1959, 1961. (5) Hansen, R. S., Frost, R. R., Murphy, J. A., J . Phys. Chem. 68, 2028 (1964). (6) Harvey, D., Norgan, G. O., in"Vapor Phase Chromatography-London, 1956," p. 74, D. H. Desty, ed. Academic Press, New York, 1957 ( 7 ) Hirschfelder, J. O., Curtiss, C. F., Bird, R. B.,"Molecular Theory of Gases and Liquids," p. 522, Wiley, New York, 1954. (8) Hoffmann, E. G., ANAL. CHE%f.34, 1216 (1962). (9) Hornstein, I., Croae, P., Ibid., 37, 170 (1965). (10) Jamieson, C. R., J . Chromatog. 3, 464. 494 11960): 4. 420 11060): 8.,,, iii'(i962): i S, i 6 0 (i964). (11) Keppler, J. G., Dijkstra, G., Schols, J. A., in"T'apour Phase Chromatography-London, 1956," p. 222, D. \ ~~
(1) Bennett, L. A., Vines, R. G., J . Chem. Phys. 23, 1587 (1955). (, 2 .) Bohemen. J.. Purnell, J. H., J . A p p l . .. Chem. 8, 433 ('1958). '
H. Desty, ed., Academic Press, New York, 1957. (12) Keulemans, A. I. M., KFantes, A,, Rijnders, G. W. A., Anal. Chim. Acta 1 6, 2 9 (1957). (13) Littlewood, A. B.,"Gas Chromatography," pp. 329-33, ilcademic Press, hew York, 1962. (14) Madison, J. J., AXAL. CHEY. 30, 1859 (1958). (15) hIessner, A. E., Rosie, D.&I., Argabright, P. A., Ibid., 31, 230 (1959). (16) Panson, A. G., Adams, L. lI., J . Gas Chromatog. 2, 164 (1964). 117) Pauschmann., H.. 2. Anal. Chem., 203. 16 11964). (18) Purcell, J. 'E., EXtre, L. S., . Gas J Chromatog. 3, 69 (1965). (19) Purnell, H., .'Gas Chromatography," D. 286, Wilev. New York, 1962. (26) Rothman
," ' A . J., Bromlep, L. A,, Ind. Ena. Chem. 47. 899 11955). (21) Schmiuch, L. J.,' Dinerstein; R. A,, ANAL.CHEM.32, 343 (1960). (22) Smith, B. I)., Bowden, W. W., Ibid., 36, 82 (1964). (23) SDencer. H. M., . Am. Chem. SOC. J
(24) 'Stuve,~K.,"Gas Chromatographyin 1958," p. 178, I). H. Desty, ed., Academic Press, X e w Ynrk. l Q 5 . (25) l'erzele, AI., J . (1964). (26) Williams, A. F., Murray, W. J., Talanta 10, 937 (1963). RECEIVEDfor review April 7, 1965. Accepted July 22, 1965. Pre-ented at the Pittsburgh Conference on Analytical Chemistry and Applied Spectroscopy, March 3, 1965.
Theory and Application of Cyclic Voltammetry f m Measurement of Electrode Reaction Kinetics RICHARD S. NICHOLSON Chemistry Department, Michigan State University, East Lansing,
Mich. surface. Under these conditions the separation of cathodic and anodic peak potentials is about 60/n mv., and the reaction is reversible. Clearly for this case no kinetic information about the electron transfer reaction can be obtained. However, if frequency is increased sufficiently, a point may be reached at which the kinetics of electron transfer become competitive with the rate of potential change. Under these conditions it may be possible to study the kinetics of the electrode reaction, and the separation of peak potentials should be a measure of the standard rate constant for electron transfer. Thus, a t least in principle, one can estimate standard rate constants simply by observing cyclic polarograms on the oscilloscope, and then increasing the triangular wave frequency until the separation of peak potentials becomes greater than 60/n mv. The standard rate constant then should be a calculable function of frequency at this peak potential separation. Unfortunately, there is no a priori way VOL. 37, NO. 1 1, OCTOBER 1965 0
b The theory of cyclic voltammetry has been extended to include electron transfer reactions which are described b y the electrochernical absolute rate equation. Results of theoretical calculations made it possible to use cyclic voltammetry to measure standard rate constants for electron transfer. Thus, a system which appears reversible a t one frequency may b e made to exhibit kinetic behavior a t higher frequencies, as indicated b y increased separation of cathodic and anodic peak potentials. The standard rate constant for electron transfer is determined from this peak potential separation and frequency. The method provides an extremely rapid and simple way to evaluate electrode kinetics. The reduction of cadmium is used as an illustration. years a number of methods have been developed for the measurement of electrode reaction kinetics. I n one sense, some of URING RECENT'
D
these determine electrode reversibility indirectly b y measuring the apparent standard rate constant for electron transfer from only cathodic (or anodic) polarization. I n a few cases both cathodic and anodic polarization give consistent results ( I S ) . Many of the relaxation techniques
developed for fast reactions have the disadvantage that small amplitude perturbations are used, and consequently differences or changes in mechanisms are not easily detected. A method which overcomes this disadvantage and a t the same time gives a direct estimate of reversibility is cyclic triangular wave voltammetry. Thus, the presence of homogeneous reactions in the mechanism is readily detected, and interpretation of results usually is simple. il direct estimate of electrode reversibility is provided, because the potentials at which oxidation and reduction occur are observed directly. For example, a t low frequencies it may be possible with a given system that electrochemical equilibrium always is maintained a t the electrode
1351

循环伏安法在测定电极反应性质方面的应用_化学_自然...电活性物质在电极上还原,产生还原波,那么 后半部分...△ Ep 的理论值为 58/n(mV) ,这 是可逆体系的...
此后这种方法得到广泛的 应用。循环伏安法也可研究无机、有机化合物电极过程 的机理,双电层、吸附现象和电极反应动力学,成为最有用的电化学方法之一。 第三章基本...
循环伏安法测定铁氰化钾的电化学行为_工学_高等教育_教育专区。循环伏安法测定铁氰化钾的电化学行为一、实验目的 1、学习循环伏安法测定电极反应参数的基本原理及...
循环伏安法测定电极反应参数_化学_自然科学_专业...在电化学、有机化学、生 物化学的研究领域应用广泛...1/2 由上式,ip 与 v 和 c 都是直线关系,对...
吸附现象和电极反应动力 学,成为最有用的电化学方法...只要电极过程可逆,反应 产物稳定,用循环伏安法测定...从 理论上计算了电极反应速 率常数k的大小对伏安曲...
伏安曲线循环伏安法(Cyclic Voltammetry)是一种常用的动电 位(循环线性电位扫描)暂态电化学测量方法,是电极反应 动力学、机理及可逆性研究的重要手段之一,应用非常...
循环伏安法测定电极反应参数_物理_自然科学_专业...无机化 学、有机化学、生物化学的研究领域广泛应用...(CN) 64-氧化时,在工作电 极表面聚集的将发生...
循环伏安法测定铁氰化钾电化学性能_工学_高等教育_教育专区。包含:实验原理,...应用 电极过程可逆性 计算电极面积、 计算电极面积、扩散系数等电化学参数 表面...
循环伏安法原理及应用小结 1 电化学原理 1.1 电解...答: 有了参比电极, 我们就可以测量/控制工作电极...电极 会发生极化 (除非是理论上的完全不可极化电极...
学习循环伏安法测定电极反应参数的基本原理。 2. 熟悉伏安法测量的实验技术。 二、方法原理 循环伏安法(CV)是最重要的电分析化学研究方法之一。在电化学、无机...
热门文档