Study of phased array techniques for concrete inspection

混凝土相控阵检查技术研究

Study of phassed array techniques for

concrete inspection

Olivia PARIS, CEA, Gif sur Yvette, France

Clarisse POIDEVIN, CEA, Gif sur Yvette, France

J. Mathieu RAMBACH, IRSN, Fontenay aux roses , France

G. NAHAS, IRSN, Fontenay aux roses , France

Abstract : From a safety standpoint the concrete containment of the nuclear power plant is one of the most essential components because it serves at the final barrier to the release of fission products. The safety authority supervises the study and development of a phased array equipment and technique for ultrasonic (US) testing of concrete structures. The aim is to detect and characterize the presence of cracks which can be responsible for loss of structural capacity and leak tight integrity of the containment. Typical frequency range used for ultrasonic testing of concrete is between 50 and 300kHz which provide a wide and non directive ultrasonic beam and yields to poor signal to noise ratios.

One objective is to use the focusing and steering of the ultrasonic beam in order to reconstruct trough imaging tools the whole profile of a detected defect. First reconstructions resulting from phased array acquisitions on an artificial crack embedded in a concrete block are presented. The study for the development of simulation tools dedicated to US concrete inspection is also briefly described and preliminary results are shown.

1. Introduction

Wall containments in Pressurized Water Reactor are extremely important because they must retain radioactive materials if an accident should occur. These walls are thick (1.2 m or 0.9m) pre-stressed and reinforced concrete structures containing pretensionned cables. The containment is cylindrical with a hemispherical dome. For the safety authority (IRSN) it is essential to maintain the integrity of the wall containment of nuclear power plant.

The concrete containment building of nuclear power plant structures are susceptible to ageing by various processes depending on the operating environment and service conditions. In order to ensure the structural capacity and leak tightness of the concrete structure it is necessary to detect cracking phenomena which is one of the primary sign of ageing. Potential degradations of the concrete material can affect the ability of Nuclear Power Plant containment to perform satisfactorily its functions. The degradation of concrete can be the result of various attacks [1]. Physical attack mechanisms include freeze/thaw cycling, thermal expansion, thermal cycling abrasion. Chemical attacks may also occur in several forms : efflorescence, attack by sulphate and by acids, salt crystallization and alkali-aggregates reaction.

Such mechanisms and fatigue effects can be responsible for surfaces and bulk flaws such as cracks, porosity and laminations.