L1=2.55mH,C2=43.8µF andL2=231.7µH.To the high frequency reproduction we used the same driverof item 4.6.Inthe band pass section we havethe closed box of Figure 18 (impedance curve).In the low end we have the tuned box ofFigure 19(impedance curve).SeeFigure 26.
4.8.2 Order Two Way CrossoverThe cut-off frequency in this case is 5 kHz. The high pass and low pass sections are depicted inFigures 12 and 13, respectively,and the parts values areC3=C4=1.99µFandL3=L4=509.3µH.Thesame loads from the item 4.6 are also used here.SeeFigure 27.
4.9.2 Order Three Way CrossoverThe cut-off frequencies in this case are 500 Hz (low), and 5 kHz (high). The high pass, low pass and bandpass sections are showed in Figures 12, 13 and 14,respectively, and the parts values areC3=1.99µF,
ndnd
Figure 17. Closed Box-

Driver A.
L3=512.3µH,C4=19.8µF,L4=L5=5.12mH,C5=25.6µF,C6=1.79µFandL6=423.5µH.The same loads from the item 4.7 are also used here.See.

Figure 28.
Figure 18. Closed Box-

Driver B.
Figure 15. Infinite Baffle-Driver A.

3
Figure 19. Vented Box-

Driver A.
Figure 16. Infinite Baffle -Driver

B.
Figure 20. Vented Box-Driver B.
AES 115TH CONVENTION, NEW YORK, NEW YORK, 2003 OCTOBER 10-13