文档下载 文档下载导航
设为首页 | 加入收藏
搜索 请输入内容:  
 导航当前位置: 文档下载 > 所有分类 > 高等教育 > 理学 > CO2 exchange in a temperate Japanese cypress forest compared with that in a cool-temperate deciduous
侵权投诉

CO2 exchange in a temperate Japanese cypress forest compared with that in a cool-temperate deciduous

科级文献

Tomakomai Experimental Forest

We compared the flux data for the Japanese cypress forest at KEW with the flux data for a cool-temperate deciduous broad-leaved forest at Tomakomai Experimental Forest (TOEF) in southwestern Hokkaido, the northernmost island of the Japanese archipelago (42°41N, 141°34E). The dominant species around the observation tower include Quercus crispula Blume, Phellodendron amurense Rupr., Acer mono Maxim., Cornus controversa Hemsl., and Ostrya japonica Sarg. The average tree height is approximately 13 m. Dryopteris crassirhizoma Nakai is distributed throughout the forest floor. Fukushima et al. (1998) reported that total LAI of TOEF, calculated by multiplying the leaf number of each species by the average leaf area within a 15-m square plot in a mature forest, was 7.59. Takahashi et al. (1999) reported that total LAI, estimated by felling all trees within a 10-m square plot in a secondary forest in TOEF, was 5.1. LAI measured with a plant canopy analyser (LAI-2000, Licor) ranged from 5–6 in peak growing periods. The mean monthly temperatures range from –3.2 to 19.1°C, and the annual precipitation is 1,450 mm. Snow cover reaches a depth of 50 cm from December to March (Hiura 2001).

Measurements

Kiryu Experimental Watershed

The CO2 flux above the temperate coniferous forest at KEW was measured at a height of 28.5 m on the observation tower. The measurements discussed here were made from 1 January 2001 to 31 December 2002. Wind speed and temperature were observed with a three-axis sonic anemometer (DAT-310 or DA-600T, Kaijo). The carbon dioxide concentration was monitored with a closed-path CO2/H2O analyser (LI-6262 or LI-7000, Licor) or with an open-path CO2/H2O analyser (LI-7500, Licor) after 30 April 2002. A closed-path infrared gas analyser (IRGA) was installed on the tower platform so as to minimise the tube length. Sampled air was drawn through a Bev-a-line plastic tube (3 m long, 3 mm i.d.) with a pump into the CO2 analyser. The average time for calculating the CO2 covariance and friction velocity was 30 min. Based on measurements of mean vertical wind speed over the long term, we assumed the practical surface to be a complex of five fans from the observation tower, and rotated the sonic wind vectors u and w toward the surface (see Fig. 1b). The time lag for CO2 was determined after every instance of maintenance and data collection to maximise the covariance between the vertical wind velocities in the closed-path system. The median of the optimised time lag for each 30-min

上一页第5页

你可能喜欢

热门文档

相关文档

站点地图 | 文档上传 | 侵权投诉 | 手机版
本站所有资源均来自互联网,本站只负责收集和整理,均不承担任何法律责任,如有侵权等其它行为请联系我们.
文档下载 Copyright 2013 doc.guandang.net All Rights Reserved.  -  email