The growth in refractive surgeries and corneal replacements has fueled interest in the developmentof a tissue-engineered cornea. This study characterizes the microstructure and biomechanical prop-erties of film-based corneal stroma equivalents over time in culture. The increased collagen densityin the films was hypothesized to result in improved mechanical properties both initially and overtime. The microstructure of the film-based stromal equivalent was examined using atomic force mi-croscopy and scanning electron microscopy; the mechanical properties, relaxed modulus, and ulti-mate tensile strength were quantified using uniaxial tensile testing. The dense, film-based stromalequivalent had a lamellae-like microstructure, which was notably different than the porous struc-ture of sponges used previously. Seeded human corneal stromal fibroblasts remained on the surfaceof the film rather than migrating into the film and produced fibers of extracellular matrix with di-ameters of 35–75 nm. After an initial decrease during hydration, the relaxed modulus and ultimatetensile strength for fully hydrated collagen films were 0.4 0.2 MPa and 0.3 0.1 MPa, respec-tively. The mechanical properties of cell-seeded films mimicked those of control films. While fur-ther studies are needed to quantify the optical properties, the dense, lamellae-like structure of col-lagen films is a feasible scaffold for the development of tissue-engineered stroma.

INTRODUCTIONing macroscopic biomechanical characteristics of the

cornea are also very important for function. In vivo, the

cornea must withstand intraocular pressures ranging from

10 to 21 mm Hg for normal humans.17In addition, the

geometric changes resulting from refractive surgery rely

on specific biomechanical properties for the cornea.17–21

Thus, the development of a corneal replacement brings

with it specific requirements for biomechanical proper-

ties.

Collagen sponges and hydrogels have been used for

corneal tissue engineering.7–12,22Previous studies per-

formed in our laboratory have shown that human stromal

fibroblasts seeded alone on collagen sponges and also co-

cultured with epithelial and endothelial cells can exhibitTcommonly transplanted tis-sue in the United States, with over 32,000 transplantsperformed annually.1,2The supply of corneal tissue suit-able for transplantation worldwide has never matched de-mand, and a similar situation may present itself in theUnited States in the next few years.1,3–6Consequently,there is interest in the development of a tissue-engineeredcornea.7–12The biomechanical and optical properties of thestroma, the middle layer of the cornea, are determined bythe unique composition and microstructure of the extra-cellular matrix.13–16The microstructure and correspond-HECORNEAISTHEMOST

1Department of Biomedical Engineering, University of Minnesota, Minneapolis, Minnesota.

2Department of Chemical Engineering and Materials Science, University of Minnesota, Minneapolis, Minnesota.

3Department of Mechanical Engineering, University of Minnesota, Minneapolis, Minnesota.