PlantandSoil(2006)282:127–134DOI10.1007/s11104-005-5374-6
ÓSpringer2006
Physiologicalindicatorsofplantwaterstatusofirrigatedandnon-irrigatedgrapevinesgrowninalowrainfallareaofPortugal
T.A.Sousa1,M.T.Oliveira2,4&J.M.Pereira3
1
UTAD,VilaReal,Portugal.2CECEA–UTAD–Fitotecnia,QuintadePrados,5001-911,VilaReal,Portugal.3CETAV–UTAD,VilaReal,Portugal.4Correspondingauthor*
Received23August2005.Acceptedinrevisedform21November2005
Keywords:leaftranspiration,leafwaterpotential,sap ow,stomatalconductance,TDR,Vitisvinifera
Abstract
Waterisakeyresourceincommercialwineproductionandbothlargeexcessesandde citshaveunde-sirablee ectsupontheamountandqualityofthewineproduced.Abalancebetweenthewaterrequire-mentsofafullydevelopedcanopyandtheinducedstressnecessaryforthecommercialqualityofthewinemustbereached.Thusweneedaphysiologicalindicatorthatintegratesbothsoilandclimaticconditionstouseasamanagementtool.Anexperimental eldwasestablishedintheeasternpartoftheDemarcatedRegionofDouro–Portugal,tostudythee ectofwatersupplyonthequalityofthemustsproducedandweneedaphysiologicalindicatorthatrelatestothewateruseandstressofthegrapevines(VitisviniferaL.)andtothelaterevaluationofthee ectofirrigationpracticesuponthequalityofthemusts.Wechoseasindicatorssap ow,leafwaterpotentialatpre-dawn(0600h),mid-morning(1000h),solarnoon(1400h)andsunset(1900h),stomatalconductanceandleaftranspirationbothmeasuredatmid-morningandatsolarnoon,andrelatedthemtoourexperimentaltreatmentsthatinducedi erencesinsoilwatercontent,evaluatedwithtime-domainre ectometryprobes,withtheobjectiveofselectingtheindicatorthatbestdescribestheplantwaterstatusunderdi erentamountsofavailablewater.Sap ow,leafwaterpotentialandleaftranspirationratemeasuredatsolarnoonhadhighlysigni cantcorrelationswithsoilwatercontentandtheirregressiononsoilwatercontentwasalsohighlysigni cant.Eachoftheseparametershasshortcomingsandnonehasaclearadvantageovertheothertwoasanintegratoroftheenvironmentalconditionsundertheseexperimentalconditions.Furtherstudiesoftheparametersandtheirrelationshipwiththequalitycharacteristicsoftheproducedmustsareneededtoachievetheultimateobjectiveofmanipulatingthesoilwatercontent.
Abbreviations:DRD–DemarcatedRegionofDouro;E–Leaftranspirationrate;gs–stomatalconduc-tance;sf–sap ow;sw–soilwater;TD–ThermalDissipation;YL–LeafwaterpotentialIntroduction
Grapevines(VitisviniferaL.)innortheasternPortugalgrowinareaswithlowwatersupplyandthevinesaresubjectedtostrongwaterstressduringthesummer.Waterisakeyresourceincommercialwineproductionandthewatersupply
*FAXNo:+351-259350327.E-mail:mto@utad.pt
tothevinesandtheirconcurrentwaterstatusarethemostimportantfactorsdeterminingwine
etal.,2001;Trambouzeetal.,quality(Chone
1998).Abundantwatersupplymayreducethequalityofthewine(ReynoldsandNaylor,1994;vanLeeuwenandSeguin,1994),thus,thegrape-vinesmustundergosomedegreeofwaterstress(Matthewsetal.,1990),however,ifwaterinputsaredrasticallyreducedthereisariskofinducingundesirablewaterde citsinthecrop(Luet

al.,
Germination, growth and physiological responses of mangrove plant 隐藏>> ...indicators of oil stress in mangrove trees.Mangrove leaf tissue sodium and ...
Statistical mechanics of neocortical interactions Portfolio of Physiological Indicators There are several kinds of non-invasive imaging methods that are used to...
plant species 10页 免费 Physiological indicators... 暂无评价 8页 8财富值...Dregne (1970) suggested that vegetation status should be the main category ...
Nowadays, the use of physiological indicators for ...of plant water status has attracted attention of ...protocols applicable for most of irrigated orchards...
basis immediately after the physiological measurements...0.8 MPa for well-irrigated vines, ?1.2 MPa ...they were to serve as indicators for water ...
Environmental indicators of water quality in the ...physiological process in the plant (see e.g., ...irrigated with saline and non-saline waters when ...
(GSSG), indicators of oxidative stress, while ...were irrigated with 30 ml distilled water per ...Determination of Biochemical and Physiological ...
(GSSG), indicators of oxidative stress, while ...were irrigated with 30 ml distilled water per ...Determination of Biochemical and Physiological ...
热门文档