广州电视台监测实例
Guangzhou New TV Tower: Integrated Structural Health Monitoring and
Vibration Control
1Y. Q. Ni and H. F. Zhou2
1 Department of Civil and Structural Engineering, The Hong Kong Polytechnic
University, Hung Hom, Kowloon, Hong Kong; PH (852) 2766 6004; Fax (852) 2334
6389; email: 2 Structural Health Monitoring Division, PolyU Technology & Consultancy
Company Limited, Hung Hom, Kowloon, Hong Kong; PH (852) 3400 2698; Fax
(852) 2356 7583; email:
ABSTRACT
The Guangzhou New TV Tower (GNTVT) with a total height of 610 m is the
landmark of the Guangzhou city in China and the tallest TV tower in the world. It
comprises a 454 m high main tower and a 156 m high antenna mast. The main tower
is a tube-in-tube structure consisting of a steel lattice outer structure and a reinforced
concrete inner structure. The antenna mast is a steel structure founded on the top of
the main tower. To ensure the safety during construction and the operational
performance during typhoons and earthquakes of this challenging structure, a
sophisticated long-term structural health monitoring system consisting of about 800
sensors has been implemented for on-line monitoring at both construction and
service stages. In the meanwhile, a hybrid mass damper control system is installed on
the main tower and two tuned mass dampers are suspended on the antenna mast for
suppressing wind-induced vibration of GNTVT. This paper outlines the structural
health monitoring system and the vibration control system for GNTVT and their
integration.
INTRODUCTION
An unprecedented level of activity in the design and construction of super-tall
structures has arisen worldwide. The examples are the Burj Khalifa of 828 m high in
Dubai, United Arab Emirates, the Shanghai Tower of 632 m high in Shanghai, China,
the Pagcor Tower of 665 m high in Manila, Philippines, the Digital Media City
Landmark Building of 640 m high in Seoul, South Korea, and the Chicago Spire of
610 m high in Chicago, USA. The new generation of super-tall structures has
become more structurally challenging and more visually exciting, posing special
challenges for their safety and performance. Structural health monitoring (SHM) is a
viable technique to address these challenges. It monitors the operating and loading
environments and the critical responses of a structure to track and evaluate the
symptoms of operational incidents, anomalies, and/or deterioration or damage
indicators that may affect operation, serviceability, or safety reliability (Aktan et al.
2000). Successful implementation and operation of SHM systems for bridges have