HO AND LO PURIFIER MANUAL OPERATION INSTRUCTION
A) 1.
2.
3.
4.
5.
6.
7. SET ALL V/VS TO REQUIRED SYSTEM. (FOLLOW SET UP INSTRUCTION) START THE PURIFIER SUPPLY PUMP. OPEN STEAM INLET AND OUTLET V/VS TO HEATER. INCREASE THE TEMP CONTROLLER TO SPECIFIED TEMP. CHECK THE GEAR CASE OIL LEVEL. START THE SEPARATOR MOTOR. ONCE PURIFIER ATTAINS WORKING SPEED, OPEN BOWL CLOSING WATER V/V SV2.
8. AFTER ~15 SECS INTERVAL OPEN SEALING WATER V/V SV3.
9. OPEN A COVER ON WATER OUTLET PIPE TO CONFIRM THAT THE BOWL IS FILLED, AND THEN SHUT BACK THE COVER. CAUTION: THE WATER MIGHT SPLASH OUT!
10. SHUT THE SEALING WATER V/V SV3.
11. OPEN BOWL OPENING WATER V/V SV1 FOR 5 SECS. (CONFIRM BY ‘THUD’ SOUND OF BOWL OPENING AND SPIKE AT AMMETER).
12. REPEAT STEPS 7 - 10
13. OPEN OIL FEED TO THE SEPARATOR BY OPENING 3-WAY V/V SV4 (PUSH DOWN RED KNOB AND TURN 180 DEG CLOCKWISE).
14. AFTER ~ 30 SECS SHUT THE BOWL CLOSING WATER V/V SV2.
15. ADJUST THE THROUGHPUT AND BACK PRESSURE ACCORDINGLY.
B) 1.
2.
3.
4. OPEN BOWL CLOSING WATER V/V SV2. OPEN THE DISPLACEMENT WATER V/V SV3. SHUT OIL FEED V/V BY OPERATING SV4. AFTER ~ 30 SECS, SHUT THE BOWL CLOSING AND DISPLACEMENT WATER V/VS SV2 AND SV3.
5. OPEN THE BOWL OPENING WATER V/V SV1 FOR 5 SECS. (CONFIRM BY ‘THUD’ SOUND OF BOWL OPENING AND SPIKE AT AMMETER).
C) 1. OPEN BOWL CLOSING WATER V/V SV2.
2. AFTER 60 SECS, SHUT OIL FEED V/V BY OPERATING SV4.
3. OPEN THE DISPLACEMENT WATER V/V SV3.
4. AFTER 16 SECS, SHUT DISPLACEMENT WATER SV3 AND BOWL CLOSING WATER V/V SV2.
5. STOP THE PURIFIER MOTOR.
6. SHUT STEAM TO HEATER AND REDUCE TEMPERATURE CONTROLLER SETTING TO 0.
7. STOP THE PURIFIER SUPPLY PUMP.
8. SHUT WATER INLET V/VS TO THE SOLENOID BOX.
*TO BE POSTED ON PURIFIER CONTROL PANEL
BOWL OPENED ACCIDENTALLY DURING OPERATION 12. LEAKAGE FROM BOWL 13. EXCESSIVE...DRAIN HO SETT TK AND ENSURE NO WATER IN TK 14. REFER TO OP MANUAL 1...
4.1 HO AND LO PURIFIER AUTO OPERATION INSTRUCTION A) STARTING 1. SET ...MANUAL DESLUDGING TO BE TRIED OUT ONCE DAILY C) STOPPING 1. STOP CD-92...
purifier, MITSUBISHI SELFJECTOR GENIUS SERIES (hereinafter referred to as ...and connection diagram Operation Manual 1 Precautions for safety Configuration ...
MANUAL OPERATION OF PURIFIERS IF AUTOMATIC CONTROL FAILS START UP Step 1 –...Step 2 – Start up the purifier motor and make sure that the operation ...
MANUAL OPERATION OF PURIFIERS IF AUTOMATIC CONTROL FAILS START UP Step 1 –...Step 2 – Start up the purifier motor and make sure that the operation ...
热门文档