EVIEW
MassSpectrometryPittCon®2005
ReviewedbyO.DavidSparkmanMassSpectrometryConsultant5354ThunderbirdCourtAntioch,CA,USA,94531E-mail:ods@compuserve.com
Theyear2005wasthemostexcitingfornewmassspectrometryintroductionsatPittConinthe11yearsthatthiscolumnhasbeenappearinginJASMS.Al-thoughtheSilverawardfromthePittConEditors’Award[thisawardhaditsoriginwithAnalyticalInstrumentIndustryReport,Dr.GordonWilkinson,FoundingEd-itor,in1995.Sincethattime,manymassspectrometryproductshavereceivedtheGold,Silver,andBronzeawards.Lastyearwasthefirstyearthatnoawardwasreceivedbyamassspectrometryproduct]wassharedbythreeproducts;onewasforamassspectrometryproduct(theShimadzuLCMS-IT-TOF).TheGoldawardwenttotheJEOLDARTandwasanoverwhelm-ingwinneratanalmostthree-to-onemajority.TheBronzeawardalsowenttoamassspectrometryprod-uct(theAgilentESILCChip).
JEOLintroducedDART,anewionizationtechniquethatmaywellbeworthyofthenextmassspectrom-etryNobelPrize.JEOLalsoshowedatPittConforthefirsttimetheAccuTof-GC,aGC-MSbasedontheirAccuTOFtechnologyintroducedasanLC-MSin2002.ShimadzuintroducedanelectrosprayversionofthetandemquadrupoleiontrapTOFmassspectrometerintroducedin2001astheMALDIAXIMAQIT.
AppliedBiosystems/SCIEXintroducedtheAPI5000triplequadrupolemassspectrometerthatboastsaten-foldincreaseinsensitivityoverpreviousmodels.
AgilentshowedatPittConforthefirsttimetheLCChipwithanelectrosprayinterfaceandintro-ducedauniquesimultaneousAPCI-ESIsourceforits1100SeriesofLC/MSsinglequadrupoleinstruments.ThermoElectronintroducedanexcitingnewglowdischargeversionofitsElementIIhigh-resolutiondouble-focusingmassspectrometer,whichistheculminationofajointeffortofitsBremen,Germany,massspectrometryfactoryandtechnologyfromVGElemental,whichwaspartoftheVGacquisitionmadeseveralyearsback.
BrukerDaltonicsintroducedfournewmassspec-trometersandtwonovelmassspectrometrycompo-nentsthatincludedasimultaneousMALDI-ESIsource.WatersshowedtheMicromassQ-TofPremier,intro-ducedatASMSin2004,forthefirsttimeatPittCon.ThisinstrumentisnowMALDI-enabled.Watersalsoshowednewlow-flowLCtechnologythatwillgreatlyenhancetheperformanceofitsmassspectrometers.
PublishedonlineApril25,2005
Anotherproductintroductionthatmaybeasrevo-lutionaryasJEOL’sDARTisthecryogen-free7-teslaFT-MSfromIonSpec.
Twonon-U.S.companies,exhibitingatPittConforthefirsttime,introducedproductsthatwereveryinteresting.ThesecompaniesareSyft(NewZealand),manufacturerofatransmissionquadrupolemassspec-trometerusingSIFTtechnologyforvolatileorganicanalyses(VOA),andPyrolab(Sweden),manufacturerofanewdimensioninpyrolysis.
Inaddition,twocompaniesthathadintroducedinstrumentconceptsinpreviousyearswerebackwithproductsreadytoship.TheywereKonik(Barcelona,Spain)withitsbenchtoptransmissionquadrupolemassspectrometerforGCandLC,andGriffinAnalyticalTechnologies(WestLafayette,IN)withitsGC-MSbasedonthePurduecylindricalquadrupoleiontrap.Therewasalsosomeinterestingnewsfromsomeoftheolderstandbycompaniesinmassspectrometry.
PittCon2005washeldinOrlando,FL,beginningFriday,February25,withshortcoursesofferedbytheAmericanChemicalSocietyandendingwiththecloseofthetechnicalprogramonFriday,March4.Theexpositionofinstruments,services,andsupplieswasfromMarch1throughMarch4.Theregistrationwasaround20,000(justunder8000confereesandjustover10,000exhibitors,withtheremainderbeingpressandstudents).Inrecentyears,PittConappearstohavebecomemoreofabusiness-to-businessconference(companiesthatmakevacuumpumpsanddetectorsdealingwithinstrumentmanufacturers),anopportu-nityforcompaniespubliclytradedonthestockmarkettoimpressWallStreet,andforventurecapitalistsandnewtechnologiestogettogether.Therearestillinstru-mentuserswhocometoseewhatisavailableinnewinstrumentation.Agoodsignfortheeconomywasacommentbyarepresentativeofoneofthemajormassspectrometrymanufacturerswhosaid,“Unlikeprevi-ousyearswhencustomerswouldcometotheboothtoseewhatwasnew,andwhattheymighttrytogetfundingfor,thisyeartheycamealreadyfundedandlookingtoseewhattheyshouldbuy.”Overall,therewerealotofcomplaintsabouttheOrlandovenue,butallthemassspectrometrymanufacturerscommentedthat“theyweregettingplentyofleads”andthatthequalityoftheleadswasquitegood.Therewasarumorthatthisyear’sPittConhad250fewerexhibitorsthanlastyear.Anotherindicatorofadeclineinthisyear’sattendancewasthe7a.m.UnitedAirlinesnonstopflightfromOrlandotoSanFranciscoonFriday,March4.Thisflight,whichhasalwaysbeenfullinthepast,hadmostofthecenterseatsopen.
TheconferenceandexpositionwasheldinthenewadditiontotheOrangeCountyConventionCenter.Thesouthentrance,theentranceclosesttotheconvention
©2005AmericanSocietyforMassSpectrometry.PublishedbyElsevierInc.1044-0305/05/$30.00
doi:10.1016/j.jasms.2005.03.027
(JAmSocMassSpectrom2005,16,967–976)
Mass_Spectrometry_生物学_自然科学_专业资料。Technology Transition Workshop Introduction to Biological Mass Spectrometry (Mass Spectrometry 101)...
Mass Spectrometry Inlet system Ion Source Mass Ion Analyzer Detector Inlet Systems Purpose is to introduce a very small amount of sample into the mass ...
现代分析技术之质谱 Mass Spectrometry (MS) 质谱 Intens. [a.u.] x10 4 0.8 0.6 0.4 0.2 0.0 2014-5-20 200 250 300 350 400 m/z 1 What ...
Mass Spectrometry_政史地_初中教育_教育专区。质谱 Mass Spectrometry 刘和文 Spectrometry NOT Spectroscopy ? ? Spectroscopy n. 光谱学, 波谱学, 光谱仪 Spectr...
Workhorses of mass spectrometry Mass Analysers: Quadrupole: Generating The Mass Spectrum DC and RF voltages cause ion oscillation Stable oscillation: ions pass...
Mass Spectrometry 质谱仪的发展起源质谱仪(mass spectrometry, MS)是以热电子撞击气体分子,使产生碎片及离 子,再经磁场分离,依据质荷比之测量,来决定分子质量的...
Gas chromatography–mass spectrometry(GC-MS)_化学_自然科学_专业资料。Gas chromatography–mass spectrometry(GC-MS) L/O/G/O GC-MS technology began in ...
SECONDARY ION MASS SPECTROMETRY (SIMS)_专业资料。SIMSSECONDARY ION MASS SPECTROMETRY (SIMS) Background The origins of SIMS may be traced all the way ...
Mass Spectrometry, MSMass Spectrometry, MS隐藏>> Chapter 12 Mass Spectrometry, MS 质谱分析原理 质谱仪器构造 质谱定性分析及图谱解析 质谱定量分析要求理解质谱...
质谱法(Mass Spectrometry, MS)_物理_自然科学_专业资料。质谱法(Mass Spectrometry, MS)第3章 质谱法 (Mass Spectrometry, MS) 分子 原子质量单位: Amu, 12...