In this report we describe the development of new approaches to measure the electric field and properties of relatively dilute plasmas under high-power pulses at the nanosecond time scale. These approaches are based on high-resolution laser spectroscopy. T
30th EPS Conference on Contr. Fusion and Plasma Phys., St. Petersburg, 7-11 July 2003 ECA Vol. 27A, O-2.1D
Use of Laser Spectroscopy for High-Accuracy Investigations of
Relatively-Dilute Pulsed Plasmas with Nanosecond Time
Resolution
, E. Stambulchik1, R. Doron1, V. Bernshtam1,
A. Fisher2, D. Osin1, and Y. Maron1
11 Department of Particle Physics, Weizmann Institute of Science, Rehovot, Israel
2Technion-Israel Institute of Technology, Haifa, Israel
In this report we describe the development of new approaches to measure the electric field and
properties of relatively dilute plasmas under high-power pulses at the nanosecond time scale. These approaches are based on high-resolution laser spectroscopy. The study is carried out in a
coaxial-pulsed-plasma configuration. The plasma was doped with a laser-produced lithium beam,
followed by pumping of a selected transition in LiI using a tunable dye laser. This setup enables
to perform spatially resolved sub-mm measurements of the electric field properties and the plasma
parameters. For the first time, line-shape diagnostics with a sub-microsecond resolution was
successfully applied to low-density plasma, down to 1013 cm-3.
Introduction
Atomic physics and spectroscopy have traditionally been used for the development of the most important methods for plasma diagnostics. One of the biggest challenges of researchers in this field is achieving high spatial and temporal resolution measurements. Such measurements are important to test and validate theories and detailed calculations, now available due to rapid development of computational capabilities. In this report, we describe a method capable of measuring the electric field and plasma parameters, such as temperature and density, on a sub-milimeter-scale. The approach described here is based on the doping of the plasma with an atomic or ionic beam, whose properties responds to the local plasma parameters, followed by laser-induced fluorescence (LIF). This technique allows for very high spatial resolution of the measurements [1]. Having a short pulsed excitation laser, a temporal resolution can be made fine enough for nanosecond-scale observations. In the present work this new approach is employed for determination of local plasma parameters using laser-produced lithium beam and LIF.
Experimental setup
This study is performed in a coaxial-pulsed-plasma configuration called Plasma Opening Switch (POS) [2]. In a POS, a large current is driven through prefilled plasma, followed by an abrupt rise in the plasma resistance and subsequent switching of the current to a parallel load. POS’s are widely used to upgrade pulsed power generators.
Experimental Investigations of New Interaction by Use of Stationary High-accuracy Quartz Gr Smooth anomalous in time dependence recordings of a high accuracy ...
Thermal analytical investigations of the magnesium alloys...a high measuring accuracy and good reproducibility....the application of relatively thin sample plates....
8/085401 Experimental investigations of micro-scale...(Lacey et al 2000), Raman spectroscopy (Liu et...the relatively long lifetime of LIP could be used...
in the experimental range with estimable accuracy....is used in most of the investigations. Recently...relatively small number of experiments in gas ...
Evidence in Forensic Investigations Abstract_专业资料...use of digital time-stamps to prove the ...accuracy, authentication, integrity, nonrepudiation ...
Investigations on Tracking and Erosion Resistance of Nano Silicone Composite for High Voltage Ou_专业资料。Spee21,ou ,.Srl.)etmbr00VlmeNo 49(ei 3 aNo4Jurloo...
A Compact Explicit Difference Scheme of High Accuracy for Extended Boussinesq Equations_专业资料。维普资讯 http://www.cqvip.com Chn eEnneig,Vo.,No.iaOcangi...
of instrument bias can improve the accuracy of ?...uorescence spectroscopy investigations. All solutions ...relatively low lamp intensity output (Fig. 2, ...
The main drawback of all previous investigations ...To improve the accuracy, the resulting radial ...high-resolution time-series spectroscopy was to ...
热门文档