文档下载 文档下载导航
设为首页 | 加入收藏
搜索 请输入内容:  
 导航当前位置: 文档下载 > 所有分类 > 工程科技 > 材料科学 > Lithium-Sulfur Battery Cathode Enabled by Lithium-Nitrile Interaction
侵权投诉

Lithium-Sulfur Battery Cathode Enabled by Lithium-Nitrile Interaction

锂硫电池

Lithium-Sulfur Battery Cathode Enabled by Lithium-Nitrile Interaction

Juchen Guo,* §‖ Zichao Yang, ‖ Yingchao Yu, Héctor D. Abruña and Lynden A. Archer*

School of Chemical and Biomolecular Engineering, Cornell University, Ithaca, NY 14853, United States

Department of Chemistry and Chemical Biology, Cornell University, Ithaca, NY 14853, United States

‖ These authors contributed equally to this work.

Supporting Information

Experimental Section

Synthesis:

All chemicals were purchased from Sigma-Aldrich unless otherwise specified and used without purification. In a typical synthesis, 0.46 g of Li2S was first reacted with 0.64 g of elemental sulfur (1:2 molar ratio) in 5 mL of DMF to form Li2S3 stoichiometrically by vigorous stirring at room temperature. The reaction can be followed colorimetrically. The initial Li2S and DMF mixture has a faint blue color, which quickly turns deep red upon sulfur addition. After stirring at room temperature for 1 h, the solid Li2S completely dissolved in DMF to produce a 2M solution of Li2S3 in DMF. Following preparation of Li2S3 solution, 0.53 g of PAN (MW = 150,000) was dissolved in 5 mL of DMF, which was then mixed with the Li2S3 solution. The molar ratio of Li to acrylonitrile units (nitrile groups) was maintained at 2:1. The resultant mixture of Li2S3 and PAN in DMF was vigorously stirred while heated at 80°C. After approximately 30 mins, the mixture became a deep-red, rigid solid, evidence that the individual PAN chains are strongly cross-linked by interaction with Li-ions.

Characterization:

The crystal structures of the products were characterized using Scintag Theta-theta PAD-X X-Ray Diffractometer (Cu Kα, λ=1.5406 Å). Their morphologies were studied using FEI Tecnai G2 T12 Spirit Transmission Electron Microscope (120kV) and elemental mapping (EDX and EELS) was performed using FEI Tecnai F20 Transmission Electron Microscope (200kV). Thermogravimetric analysis was performed using TA Instruments Q5000 IR Thermogravimetric Analyzer. Raman spectra were collected using a Renishaw InVia Confocal Raman Microscope (laser wavelength = 488nm) with samples containing Li2S sealed in a glass holder. Fourier Transform Infrared Spectra

第1页

你可能喜欢

热门文档

相关文档

站点地图 | 文档上传 | 侵权投诉 | 手机版
本站所有资源均来自互联网,本站只负责收集和整理,均不承担任何法律责任,如有侵权等其它行为请联系我们.
文档下载 Copyright 2013 doc.guandang.net All Rights Reserved.  -  email