文档下载 文档下载导航
设为首页 | 加入收藏
搜索 请输入内容:  
 导航当前位置: 文档下载 > 所有分类 > 自然科学 > 生物学 > Effect of sulfate and redox mediator on reduction of AO7 in upflow anaerobic filter(UAF) -final
侵权投诉

Effect of sulfate and redox mediator on reduction of AO7 in upflow anaerobic filter(UAF) -final

kinetics while the downside fitting the zero-order kinetics.

As shown in table 1, addition of RF (F2), as a redox mediator, increased the rate constant of decolorization, such as from 0.041 to 0.053 min-1, compared to the control lacking this catalyst (F1). This is because the electrons released from electron donor are likely transferred to RF and then are used to reduce the azo dyes extracellularly [11], thus enhancing the AO7 reduction rate. The comparison between F3 and F1 indicating that the sulfate-reduction may have contributed to the reduction of AO7 probably by biological mechanisms through anaerobic substrate oxidations and by the chemical contribution of biogenic sulfide generated [12]. It was also noted that when RF was included as a redox mediator with the sulfate (F4), the reduction rate of AO7 can be significantly increased (compare F4 with F1), for example, when the AO7 influent concentration is 1.0 mM, the reduction rate constant in F4 is 0.046 mM·min-1, almost two times of that (0.026 mM·min-1) in F1. The reason for this phenomenon might be the RF can decrease the toxicity effects of sulfide over the anaerobic consortia. Thus, application of redox mediators, such as RF, to sulfide-containing system would improve the decolorising processes, allowing for an overall robustness of bioreactors. 1.2

1.0

0.8 0.6

0.4

0.2

AO7 (mM)

AO 7 (mM)

0.01.2

Effect of sulfate and redox mediator on reduction of AO7 in upflow anaerobic filter(UAF) -final

1.0

0.80.60.40.20.0

Height (cm)

Height(cm)

Fig. 4 AO7 reduction kinetics profile of four UAF under different operation conditions.

(A): F1; (B): F2; (C):F3; (D): F4.

Summary

The successfully-established UAF system can lead to a high performance. The addition of sulfate and RF greatly affects AO7 reduction and system performance. This lab-scale study stated that it is possible to speed up the start-up of AO7 reduction system under appropriate condition. Acknowledgements

This research was supported by the Foundation of the State Key Laboratory of Pollution Control and Resource Reuse, China (No. PCRRK09004), the National Science Foundation of China (51078284), and the Key Special Program on the S&T for the Pollution Control and Treatment of Water Bodies of

上一页第5页

你可能喜欢

热门文档

相关文档

站点地图 | 文档上传 | 侵权投诉 | 手机版
本站所有资源均来自互联网,本站只负责收集和整理,均不承担任何法律责任,如有侵权等其它行为请联系我们.
文档下载 Copyright 2013 doc.guandang.net All Rights Reserved.  -  email