600 Vol. 60, No. 5
2-acetamidovinyl)-benzene, which was synthesized from and 2-propanol showed the same spectrum as ethanol (Fig. p-N,N-dimethylamino-benzaldehyde and 2-cyanoacetamide, 1). The emission spectra of the reaction mixture containing and the uorescence maxima were red-shifted with increasing acetonitrile showed a shoulder around 500 nm. Moreover, the solvent polarity.31) In this study, the uorescence spectra and emission spectra of the reaction mixture containing methanol intensity from the reaction mixture of idebenone with 2-cya-showed a broad peak at about 410 nm. The addition of water or noacetamide were also affected by organic solvents and water acetone to the reaction mixture did not produce uorescence. (their solvent volume was 50 v/v%). The emission spectra were The eluent composition of ethanol aqueous solution was used measured at an excitation wavelength of 358 nm. 1-Propanol for HPLC because it showed the highest uorescence intensity
at 409 nm for the solvents, and the excellent separation of ide-benone from other uorescent substances in blood.Fluorimetric HPLC for Idebenone The reaction of 2-cy-anoacetamide with idebenone under alkaline conditions was available for HPLC with post-column uorescence derivatiza-tion. The chromatographic conditions were optimized using a standard solution of idebenone. The optimal concentration of reagents for the uorescence derivatization was investi-gated over the ranges of 0.5–4 mmol/L for 2-cyanoacetamide, and 20–100 mmol/L for sodium hydroxide. The maximum uorescence intensities for the uorescence of idebenone were obtained at concentrations of 3 mmol/L 2-cyanoacetamide and 80 mmol/L sodium hydroxide. The reaction temperature was investigated over the range of 50–75°C. The baseline was unstable over a temperature of 65°C and the maximum peak area was observed at 60°C. In addition, 3 mmol/L sodium perchlorate as an anionic ion pair reagent in the eluent was
Fig. 1. The Fluorescence Excitation (Ex) and Emission (Em) Spectra of
0.03 mmol/L Idebenone Allowed to React with 2.4 mmol/L 2-Cyanoacet-effective for excellent separation of idebenone from other
uorescent substances in blood.7,32) On the other hand, 2-cya-amide, 16 mmol/L Sodium Hydroxide, and 2.4 mmol/L Sodium Perchlo-rate in Ethanol (50 v/v%) at 60°C for 5

minnoacetamide was soluble and stable in the eluent;

therefore,
Fig. 2. Possible Mechanism of Fluorescence Derivatization by the Reaction of Idebenone and Reduced Form of Idebenone with 2-Cyanoacetamide under Alkaline Conditions
Determination of Mirtazapine in Human Plasma by HPLC-MS and Bioavailability of Newly Developed Mirta_医药卫生_专业资料。生物利用度...
HPLC-MS/MS method for the determination of ... in parallel with continuous post-column infusion ...cient to determine plasma iohexol concentration. ...
HPLC–APCI–MS for the determination of vitamin K1 in human plasma_医药...(Agilent Technologies, Palo Alto, CA) with a Sepax GP-C8 column, 5 m...
Validation of Metformin Hydrochloride in Human Plasma by HPLC-Photo Diode Array (PDA) for Appl_专业资料。Julficecs21)02 omaoL~Sie 022—7 n6( Vaiai ...
post-column unit for oxidation of LMG and with ...sh (muscle and plasma) [4,6,7] and in ...HPLC analysis method for determination of residues ...
Validation of Metformin Hydrochloride in Human Plasma by HPLC-Photo Diode Array (PDA) for Appl_专业资料。Julficecs21)02 omaoL~Sie 022—7 n6( Vaiai ...
热门文档