Smart SN
ELECTRONIC PRESSURE TRANSMITTERS

PRODUCT DATA
Ambient (operating) temperature and humidity Versions without HMI -20...+80 °C Versions with HMI -20...+70 °C Humidity 0...95% r.h., non-condensing Temperature of medium -20...+80 °C
Climate class Indoors 4K4H as per EN 60721-3-4 Outdoors 3K8H as per EN 60721-3-3
Mechanical stability Vibration 20 g as per IEC 68-2-6 (up to
2000 Hz)
Mechanical shock 100 g as per IEC 68-2-27
Device resistance / Accuracy (combined non-linearity, hysteresis, and repeatability at 20 °C)
pressure range P ≤ 16 bar P > 16 bar overpressure safety 2x PnominalPnominal burst pressure 4x PnominalPnominal sensor type piezo thin-film max. ±0.8% FS max. ±1% FS
accuracy
±0.5% FS (typ.) ±0.6% FS (typ.)
Honeywell FEMA's Smart SN Electronic Pressure Trans-Pressure meas. range 0…40 bar, -1…1 bar mitters are microprocessor-controlled pressure measurement
Cycle time 100 ms devices for relative pressure ranges of -1…+1 bar and
0…40 bar. They are suitable for an extremely wide range of
Protection rating applications, including the precision recording and monitoring
Models without HMI IP67 as per EN 60529-2 of system pressures. They come complete with an angled
Models with HMI IP65 as per EN 60529-2 M12x1 plug and are screwed (G1/2”) directly into the line /
EMC Conforms to EN 61326 vessel to be monitored. 2- and 3-wire versions available.
Protection class 2 as per EN 61010
Process connection G1/2" external thread
Configurable as 0/2…10 V or 0/4…20 mA (3-wire) Electrical connection 4-prong A-coded M12x1 plug
Adjustable attenuation filter
Transmitter (analog) output LCD graphical display (Human-Machine-Interface models,
Current (2-wire) 4…20 mA only) can be swiveled for better readability; display can be
Voltage / current (3-wire) 0/2...10 V, 0/4...20 mA rotated in 90° steps by software
Voltage supply (2-wire) 18…35 Vdc Self-monitoring
Voltage supply (3-wire) 18…35 Vdc, 24 Vac +10%/-20%,
max. 50 mA
Current output max. load = (VSUPPLY - 16 V) /
Materials 22 mA (max. error ±0.25% FS) Parts in contact w/ medium Stainless steel (1.4571) Voltage output min. load = 15 k (max. error Chemical resistance 4C4 as per EN 60721-3-4 ±0.25% FS) HMI PA66 GF25 Transient response approx. 200 ms Total weight 300 grams (non-HMI models)
350 grams (HMI models) Span, offset, and long-term drift (within temperature
compensation range of 0…80 °C) Storage temperature max. typical Versions without HMI -40...+80 °C (≤ 16 bar) temp. effect on span ±0.3% FS / 10 K ±0.2% FS / 10 K
-40...+100 °C (> 16 bar) temp. effect on offset ±0.3% FS / 10 K ±0.2% FS / 10 K
Versions with HMI -30...+80 °C long-term drift ±0.3% FS / year ±0.2% FS / year
FEATURES
TECHNICAL DATA
® U.S Registered Trademark
Copyright © 2007 Honeywell Inc. All Rights Reserved

MU0B-0560GE51 R0707
Fema 压力开关: 空气+空气调节: 气体压力开关 HCD 空气差压开关 DPS 流体+气体+电子: 气体/液体电子压力开关 Smart SN 气体/液体电子压力开关 Smart DCM 高粘性...
FEMA开关的推广策略 FEMA开关的推广策略 2 HSJW - CONFIDENTIAL File Number ...高粘性搅动液体电子压力开关SmartPress(PST系列) 系列) 高粘性搅动液体电子压力...
设计应有 应遵循SMART原则 财务收益预估 团队成员组成 宏观流程图 宏观流程图 ... FEMA是团队的结晶; 针对初步筛选后的因子进行再次筛选,哪些需要进行图形分析或...
//www.fema.rbi.org.in 印度进出口银行 http://www.eximbankindia.com 印度...msn (自制目录 + looksmart) 3. google (+odp) 4. goo/infoseek japan/...
(bar) 0.75 1.8 3 6.4 7.5 6 18 30 38 75 80 120 3 圣懋控制压力变送器 SMART PT Honeywell FEMA Smart PT 系列压力变送器是 由微处理控制,测量...
CALESCO研发中心可以为客户提供准确热量分布及FEMA分析 CALESCO可以提供从0-10W/ ...SMART W211 TOYOTA YARIS 981 223 AVENSYS 592 12 500 PSA-CITROEN PSA307 ...
②扩增产物含量测定 : Smart2 Spectro 3000 型核酸定量仪测 A 值对 DNA 进行...2 压电传感器阵列检测 ,结果见表 2 株葡萄球菌的 femA 基因扩增产物与 femA ...
设计应有 应遵循 SMART 原则 财务收益预估 团队成员组成 宏观流程图 测量 (每个... FEMA 是团队的结晶; 3、 分数的评定没有绝对的标准, 但自己的标准要 一致;...
//www.fema.rbi.org.in 印度进出口银行 http://www.eximbankindia.com 印度...msn (自制目录 + looksmart) 3. google (+odp) 4. goo/infoseek japan/...
32、工作小组可利用头脑风暴法,8D,5W,鱼骨图,FEMA,6Sigma 等工具进行问题分析...(×) 58、工艺流程/输送装置的设计要应用 SMART 卡片和物料超市来确保在正确的...
热门文档